GDRB-C Power Transformer Winding Deformation Tester
Power transformer winding deformation tester (mokgwa wa karabelo ya kgafetsa) e ipapisitse le tekanyo ya diparamente tsa sebopeho sa transfoma e ka hare, e amohela mokgwa wa ka hare wa karabelo ya phoso (FRA), e ka ahlolang diphoso tsa ka hare tsa diphetoho ka nepo.
Ka mor'a ho phethoa ha moralo le ho etsoa ha li-transformer, li-coil le sebopeho sa ka hare li phethoa, kahoo bakeng sa coil ea transformer e nang le maqhubu a mangata, haeba boemo ba motlakase le mokhoa oa ho phalla li tšoana, li-parameter tse lumellanang (Ci, Li) tsa e 'ngoe le e 'ngoe. khoele e tla khethoa.Ka hona, karabelo ea litšoaneleho tsa khafetsa tsa coil ka 'ngoe le eona e tla khethoa, ka hona, maqhubu a maqhubu a likhoele tse tsamaellanang tsa mekhahlelo e meraro a ka bapisoa.
Nakong ea tlhahlobo ea transformer, haeba ho e-ba le potoloho e khuts'oane ea li-inter-turn, inter-phase short circuit, kapa ho falla ha coil ho bakoang ke ho thulana nakong ea lipalangoang, hammoho le deformation ea coil e bakoang ke tsitsipano ea motlakase nakong ea ts'ebetso tlas'a potoloho e khutšoanyane le maemo a phoso, litekanyetso tsa kabo. Maqhubu a li-transformer a tla fetoha, 'me ka hona a ama le ho fetola litšoaneleho tsa mantlha tsa li-frequency frequency domain, e leng phetoho ea karabelo ea maqhubu ka boholo le ho fetoha ha lintlha tsa maqhubu a resonant.Teko ea li-transformer winding e ntlafalitsoeng ho latela mokhoa oa tlhahlobo ea karabelo ke sesebelisoa se secha sa NDT sa ho bona phoso ea kahare ea transformer.E sebetsa tabeng ea ho lemoha phoso ea sebopeho sa ka hare ho li-transformer tsa matla a 63kV-500kV.
Transformer winding deformation tester ke ho fumana hore na ho na le liphetoho tse kae lipakeng tsa ka hare tsa transformer tse ipapisitseng le bongata ba phetoho, boholo le sebaka se amang phetoho le tšekamelo ea phetoho ea karabelo e lekantsoeng ho tsoa ho liphetoho tsa karabelo libakeng tse fapaneng tsa maqhubu a kahare a transfoma. parameters, 'me joale e ka u thusa ho tseba hore na transformer e senyehile haholo, kapa e hloka phetoho e kholo ho latela liphello tsa tekanyo.
Bakeng sa transformer e sebetsang, ho sa tsotellehe hore na setšoantšo sa "frequency domain characteristic drawing" se bolokiloe, ka ho bapisa phapang pakeng tsa li-inter-coil character spectra ea transformer e fosahetseng, e ka tseba hore na ho hlōleha ho hokae.Ha e le hantle, haeba u bolokile litšoantšo tsa sebopeho sa li-transformer windings tsa pele, ho tla ba bonolo ho fana ka motheo o nepahetseng oa maemo a ts'ebetso, tlhahlobo ea morao-rao le ho lokisoa ha phetoho ea transformer.
Transformer winding deformation tester e entsoe ke komporo ea laptop le micro controller e etsang sistimi ea tekanyo e nepahetseng e nang le sebopeho se kopaneng, ts'ebetso e bonolo, e nang le ts'ebetso e felletseng ea tlhahlobo ea liteko, e ka sebetsoang ho latela bukana ea litaelo kapa ka koetliso ea nako e khuts'oane.
●Ho fumana le ho laola ho sebelisa microprocessor ea lebelo le holimo, e kopantsoeng haholo.
●Khokahano ea puisano ea USB e sebelisoang lipakeng tsa laptop le sesebelisoa.
●Ha ho hlokahale ho sebelisa k'homphieutha ea selefouno tšimong ea tekanyo ka lebaka la ho kopanngoa ha k'homphieutha ea indasteri le sesebelisoa sa ho lekanya.
●Hardware e sebelisa theknoloji e inehetseng ea DDS digital high-speed scanning (USA), e ka hlahlobang liphoso ka nepo joalo ka matsoelintsoeke a sothehileng, a matsutla-tsutla, a sisinyeha, a sekamehang, a feto-fetoha le maemo a makhuts'oane a potoloho e khuts'oane le li-inter-phase contact short-circuit.
●Sampling ea lebelo le habeli la li-channel tse peli tsa 16-bit A/D (tekong ea masimong, mofetoleli oa theipi, 'me leqhubu le bonts'a liphetoho tse hlakileng).
●Bophahamo ba pontšo ea pontšo bo lokisoa ke software, 'me boleng ba tlhōrō ea amplitude ke ± 10V.
●Khomphuta e tla itlhahloba ka bo eona sephetho sa liteko ebe e hlahisa litokomane tsa elektroniki (Lentsoe).
●Sesebelisoa se na le likarolo tse peli tsa litekanyo: tekanyo ea ho lekanya maqhubu le tekanyo ea sekhahla sa sekhahla, e tsamaellanang le mokhoa oa ho lekanya oa lihlopha tse peli tsa tekheniki naheng ea China.
●Litšobotsi tsa amplitude-frequency li lumellana le litlhaloso tsa naha tsa tekheniki ho tester ea litšobotsi tsa amplitude-frequency.X-coordinate (frequency) e na le linear indexing le logarithmic indexing, kahoo mosebelisi a ka hatisa mokokotlo ka indexing ea linear le indexing ea logarithmic.Mosebelisi a ka khetha ho latela litlhoko tsa 'nete.
●Sistimi ea tlhahlobo ea data e ikemetseng,
Papiso e tšekaletseng ea ho tšoana ho hoholo lipakeng tsa mekhahlelo e meraro A, B le C
Liphetho ke tse latelang:
① Ho lumellana ho hotle
② Ho tsitsisa hantle
③ Ho se tsitsisehe hantle
④ Boemo bo bobe le ho feta
Papiso ea longitudinal AA, BB, CC e bitsa data ea mantlha le data ea hajoale mokhahlelong o ts'oanang oa papiso ea deformation
Liphetho tsa tlhahlobo ke:
① Maqhubu a tloaelehileng
② Deformation e bonolo
③ Deformation e itekanetseng
④ Deformation e matla
●Tokomane ea elektronike ea Lentsoe e ka hlahisoa ka bo eona bakeng sa ho boloka le ho hatisoa.
●Sesebelisoa se ka fihlela litlhoko tsa tekheniki tsa standard standard DL/T911-2004 "Frequency response analysis on winding deformation of power transformers".
Mokhoa oa ho hlahloba:
1. Kabo ea linear scanning
Lethathamo la tekanyo ea ho lekanya: (10Hz) - (10MHz) 40000 ntlha ea ho hlahloba, qeto ea 0.25kHz, 0.5kHz le 1kHz.
2. Kabo ea tekanyo ea ho lekanya maqhubu a karolo
Lethathamo la tekanyo ea ho lekanya khafetsa: (0.5kHz) - (1MHz), lintlha tse 2000 tsa ho hlahloba;
(0.5kHz) - (10kHz)
(10kHz) - (100kHz)
(100kHz) - (500kHz)
(500kHz) - (1000kHz)
Lintlha tse ling tsa tekheniki:
Lekhalo la tekanyo ea amplitude | (-120dB) ho ea ho (+20 dB); |
Ho nepahala ha tekanyo ea amplitude | 1dB; |
Ho nepahala ha maqhubu | 0.01%; |
Ho sitisa ho kenya letshwao | 1MΩ; |
Letšoao la tlhahiso ea impedance | 50Ω; |
Letšoao la tlhahiso ea amplitude | ± 20V; |
Sekhahla sa ho pheta-pheta teko | 99.9%; |
Litekanyo tsa lisebelisoa tsa ho lekanya (L*W*H) | 300*340*120 (mm); |
Lebokose la aluminium la lisebelisoatekanyo(L*W*H) | 310*400*330 (mm); |
Boima ka kakaretso | 10kg; |
Mocheso o sebetsang | -10℃~+40℃; |
Mocheso oa polokelo | -20℃~+70℃; |
Mongobo o amanang | <90%, Non-condensing; |
Che. | Lebitso | Qty. | Yuniti |
1 | Ka sehloohongtaolounit | 1 | beha |
2 | Moetapele oa tlhahlobo ea karabelo khafetsa | 2 | likotoana |
3 | Setlapa sa teko | 2 | likotoana |
4 | Cable ea fatše | 4 | likotoana |
5 | Setlamo sa ho thella | 2 | likotoana |
6 | Mohala oa puisano oa USB | 1 | sengoathoana |
7 | Ho kenya Software CD-ROM VCD Format | 1 | meqolo |
8 | Ho kenya Software USB disk | 1 | sengoathoana |
9 | Fuse | 3 | likotoana |
10 | Mohala oa motlakase le adaptara | 1 | sengoathoana |
11 | Tataiso ea mosebelisi | 1 | sengoathoana |
12 | Karete ea tiisetso | 1 | sengoathoana |
13 | Lenane la ho paka | 1 | sengoathoana |
14 | Tlaleho ea tlhahlobo ea fektheri | 1 | sengoathoana |