GDJF-2008 Mohlahlobi oa Phallo ea Karolo
GDJF-2008 Partial Discharge Detector e lekanya ho tsoa ka mokhoa o sa fellang bakeng sa lihlahisoa tse kang li-transformer, li-inductors tse kopanetsoeng, li-switches tsa HV, li-cutter tsa zinc monoxide le likhoele tsa motlakase.E ka boela ea etsa liteko tsa mofuta le ho beha leihlo ts'ebetso ea insulation.
Mofuta ona o na le melemo ea ho ba le kutlo e phahameng, matla a mangata a fapaneng, ho hlomelloa hantle bakeng sa ho lemoha li-unit impedance le mefuta e mengata ea maqhubu a maqhubu (9 ho bohle).Ka mor'a hore ho behoe hantle, palo ea tšusumetso ea ho ntša e ka baloa ka ho toba.Limithara tse bontšang le tsa digital li bontšoa ka nako e le 'ngoe.
Sesebelisoa sena se sebelisoa haholo liteisheneng tsa motlakase, bahlahisi le mekhatlong.
●Mocheso oa tikoloho: 0-40℃±2℃.
●Mongobo o amanang: ≤80%
●Phepelo ea matla: 220V ± 10%, 50HZ.
●Ha ho na vibration e matla le ts'isinyeho ea mochini.
●Sesebelisoa se lokela ho behoa tikolohong e se nang lerōle le e senyang, moea o motle.Ha ea lokela ho sitisoa ke motlakase o matla oa motlakase.
●Litlhoko tsa mobu: khanyetso ea mobu <1Ω.
●Sebaka sa bokhoni se tla lekoa 6PF-250μF.
●Boikutlo ba teko (bo bontšitsoeng ho Lethathamo.1).
Ntho ea ho kenyaChe. | Tuning capacitance | Yuniti | Sensitivity(pC)(Potoloho e sa leka-lekaneng) |
1 | 6-25-100 | pF | 0.02 |
2 | 25-100-400 | pF | 0.04 |
3 | 100-400-1500 | pF | 0.06 |
4 | 400-1500-6000 | pF | 0.1 |
5 | 1500-6000-25000 | pF | 0.2 |
6 | 0.006-0.025-0.1 | mF | 0.3 |
7 | 0.025-0.1-0.4 | mF | 0.5 |
8 | 0.1-0.4-1.5 | mF | 1 |
9 | 0.4-1.5-6.0 | mF | 1.5 |
10 | 1.5-6.0-25 | mF | 2.5 |
11 | 6.0-25-60 | mF | 5 |
12 | 25-60-250 | mF | 10 |
7R | Khanyetso |
| 0.5 |
●Sehlopha sa amplifier
Terminal e tlase: 10KHZ, 20 KHZ, 40 KHZ (ho ikhethela)
Terminal e phahameng: 80 KHZ, 200 KHZ, 300 KHZ (ho ikhethela)
● Amplifier e fumana phetoho
Taolo e thata - ho na le likere tse 6 bakeng sa tokiso e mahoashe, phaello ea gear ka 'ngoe ke 20±1db.
Taolo e ntle ≥ 20 db
● Lifensetere tsa nako
Bophara ba fensetere, e ka fetolehang 15o-150o
Fensetere boemo, fetolehang 0o-170o
Lifensetere tse peli li ka buloa ka nako e le 'ngoe kapa li arohane.
● Metara ea ho lahla
Pontšo ea dijithale
Pontšo ea PD: LED ea linomoro tse 3½
0-100.0 moeli oa phoso <± 3% (sekala se felletseng)
● Motheo oa nako ea Ellipse
Khafetsa: 50Hz le khafetsa khafetsa
'Mala oa elliptic o mosehla
Ho potoloha ha elliptic: gear e 'ngoe le e' ngoe ke 30 °, ho ka etsoa ho potoloha ha 180 °.
Pontšo: ellipse - mola o otlolohileng
Nako e phahameng ea maqhubu a motlakase oa elliptical input e ka tlase ho 220 V, matla a ho kenya <1 VA
● Senotlolo sa waveform
Notlela mofuta o hlokahalang oa maqhubu nako efe kapa efe ho thusa ho shebella le ho sekaseka
● Teko ea Voltage meter
Range: 100KV (E ka atolosoa)
Hlahisa 31/2 dijithale voltage meter
Ho nepahala: ho feta ± 2% (sekala se felletseng)
● Hare, kantle ho ts'ebetso ea zero-mark
●Litekanyo: 450×450×190 limilimithara
●Boima ba 'mele: hoo e ka bang 16kg