VLF AC Hipot Test Set
Teko ea ho mamella voltage ke teko ea bohlokoa ea thibelo bakeng sa lisebelisoa tsa motlakase.E arotsoe ka likarolo tse peli: AC le DC e mamella teko ea motlakase.Teko ea AC e ka aroloa hape ka maqhubu a matla, maqhubu a feto-fetohang le tlhahlobo ea 0.1Hz e tlase haholo, eo ea ho qetela e khothalletsoang haholo ke IEC, ka lebaka la melemo ea eona e makatsang.
Se latelang ke papiso ea DC, Power Frequency, Variable Frequency, le tlhahlobo ea 0.1Hz.
Likarolo | DC | Maqhubu a Matla | Fetohang Frequency | 0.1Hz |
Tekano | mafutsana | molemo | molemo | molemo |
Tšenyo ea Insulation | e matla | hanyane | hanyane | hanyane |
Tšireletseho ea Ts'ebetso | batla ba tlase | batla ba tlase | batla ba tlase | hodimo |
Bothata ba Wiring | rarahane | rarahane | rarahane ka ho fetisisa | bonolo |
Bolumo | e nyane ka ho fetisisa | kholo ka ho fetisisa | e kgolo | nyane |
Ha e le hantle tlhahlobo ea VLF ke eona e nkang sebaka sa tlhahlobo ea maqhubu a matla.E loketse ho lekola lisebelisoa tsa motlakase tse nang le matla a maholo (joalo ka thapo ea motlakase, capacitor ea matla, enjene le jenereithara).
Moloko o mocha oa VLF series 0.1Hz VLF AC Hipot Test Set e ntlafalitsoeng ke HV Hipot e amohela "Smart Quick" tsamaiso e bohlale ea teko ea matla (Soft No. 1010215, nomoro ea ngoliso ea letšoao la khoebo 14684781), k'hamphani ea HV HIPOT e hlahisitse lisebelisoa tsa morao-rao tsa motlakase tsa machaba tsa motlakase le theknoloji ea morao-rao ea ARM7 microcontroller, e fokotsang boholo le boima ba lisebelisoa.Ts'ebetso e bonolo, 'me ts'ebetso e tsitsitse haholoanyane.
●Theknoloji e tsoetseng pele e sebelisa theknoloji ea ho fetola maqhubu a dijithale, taolo ea microcomputer e ikemetseng ka botlalo, matla a motlakase, ho theoha, tekanyo, ts'ireletso, jj.
●Karolo ea taolo le karolo ea High-voltage e amohela moralo o kopaneng oa sebopeho, 'me ho hlokahala terata e phahameng ea motlakase feela le terata ea fatše ho hokela sehlahisoa se lekiloeng ntle le terata ea khokahano e mahareng.
●Moralo oa mofuta oa trolley o loketse lipalangoang libakeng tse fapaneng tsa ts'ebetso, 'me boholo ba eona bo nyane le boima bo bobebe bo thusa haholo ts'ebetsong ea kantle (80kV).
●Tšireletso e feteletseng ea motlakase le tšireletso ea over-current.Nako ea ts'ebetso ha e fete 10ms.
●Setsi sa taolo le booster li hokahane ka matla a tlase, ka taolo ea ho itšehla thajana ea photoelectric, e bolokehileng ebile e ka tšeptjoa ho sebelisoa.
●Potoloho ea maikutlo e fosahetseng ea loop e koetsoeng e amoheloa.Ha ho matla a nyolohang nakong ea tlhahiso.
●Capacitive touch screen, LCD graphic display, automatic storage, and printing.
●0.1Hz, 0.05Hz le 0.02Hz li ka khethoa, tse tiisang hore ho na le mefuta e mengata ea liteko.
●Matla a phahameng: 30kV
●Khafetsa ea teko: 0.1Hz, 0.05Hz le 0.02 Hz (e khethiloeng)
● Maximum load capacity: 1.1μF@0.1Hz / 2.2μF@0.05Hz / 5.5μF@0.02Hz
●Ho nepahala ha tekanyo: 3%.
●Phoso ea tlhoro ea motlakase: ≤3%.
●Ho senyeha ha maqhubu a motlakase: ≤5%.
●Sebaka sa ho sebetsa: ka hare kapa ka ntle;-10℃-+40℃;85% RH
●Fuse: 8A (30kV)
●Phepelo ea matla: 220V ± 10%, 50Hz ± 5% (Haeba u sebelisa jenereithara e nkehang, etsa bonnete ba hore motlakase o hlahisoang le maqhubu a tsitsitse. Matla > 3kW, frequency 50Hz, voltage 220V±5%.)
●Bokhoni ba ntho e lekiloeng e ke ke ea feta max.rated capacitance of the seletsa.