AC High Voltage Test Sets bakeng sa GIS
●Transformer
●Sistimi ea GIS
●SF6 switchgear
●Lithapo
●Bushing
●Sesebelisoa sa motlakase
●CT/PT
●Lisebelisoa tse ling tsa capacitive
●Mocheso o monyenyane o nyoloha ka mojaro o lekantsoeng.Li-reactors tsa mofuta o omileng kapa oa Oli, matla a phahameng a mochini, li-insulation tse ntle, tse ntle ebile lia tšepahala.
●Matla a feto-fetohang a mohloli oa taolo ea maqhubu.Tšireletso e matla, botsitso bo botle.Ka mekhoa e mengata ea ho sebetsa, ho bonolo ho e sebetsa.
●Ka 220V kapa 380V matla a mohato o le mong, a loketseng ho fumana matla sebakeng sa marang-rang.
●Phetoho e feto-fetohang.Mefuta e fapaneng ea li-reactor bakeng sa boikhethelo, e fihlela litlhoko tse fapaneng tsa tlhahlobo.Mesebetsi e mengata, e theko e tlaase.
●Rated output voltage: e ipapisitse le lintho tse fapaneng tsa liteko.
●Khafetsa ea tlhahiso: 20-300Hz.
●Waveform: pure sine wave, THD <1.0%.
●Max.matla: 1000kVA le ka tlase.
●Mosebetsi oa Cycle: Nako e tsoelang pele ea ho sebetsa 15mins nako e le 'ngoe ka matla a feletseng a matla.(kapa tlhoko ea bareki.)
●Maikutlo a ho fetola khafetsa: 0.1Hz, ho hloka botsitso <0.05%.
●Phepelo ea Matla: 380/220V ± 15%/50Hz ± 5%.
GDTF-108/108 | |
Matla a kenang (V) | 380 |
Matla a tsoang (kV) | 0-108 |
Bokhoni (kVA) | 108 |
Sebaka sa kopo | 31500kVA kapa ka tlase |
35kV transformer ea matla | |
35kV potoloho breaker le libese bar, insulators | |
10kV (300 mm²) mohala oa 2000m | |
35k V (300 mm²) cable 500m | |
Litlhophiso tsa mantlha | 5kW Mohloli o feto-fetohang oa maqhubu 1 sete |
5kVA Transformer e thabisang 1 sete | |
Reactor 27kV/1A 4sets | |
Capacitive divider 100kV | |
GDTF-216/216 | |
Matla a kenang (V) | 380 |
Matla a tsoang (kV) | 0-216 |
Bokhoni (kVA) | 216 |
Sebaka sa kopo | 110kV Circuit breaker le sebaka sa libese |
110kV GIS | |
35kV(300 mm²) cable 1500m | |
10kV(300 mm²) cable 3km | |
110kV e tletseng insulation Transformer | |
Litlhophiso tsa mantlha | 10kW Mohloli o feto-fetohang oa maqhubu 1 sete |
10kVA Transformer 1 sete | |
Reactor 54kV/1A 4sets | |
Capacitive divider 200kV | |
GDTF-270/270 | |
Matla a kenang (V) | 380 |
Matla a tsoang (kV) | 0-270 |
Bokhoni (kVA) | 270 |
Sebaka sa kopo | 110kV GIS le transformer |
110kV GIS le transformer | |
35kV (300 mm²) cable 2km | |
Litlhophiso tsa mantlha | 15kW Mohloli o feto-fetohang oa maqhubu 1 sete |
15kVA Transformer e thabisang 1 sete | |
Reactor 54kV/1A 5sets | |
Capacitive divider 300kV | |
GDTF-400/400 | |
Matla a kenang (V) | 380 |
Matla a tsoang (kV) | 0-400 |
Bokhoni (kVA) | 400 |
Sebaka sa kopo | 220kV GIS le transformer |
10kV (300 mm²) cable 4km | |
35kV (300 mm²) cable 1km | |
Litlhophiso tsa mantlha | 20kW Mohloli o feto-fetohang oa maqhubu 1 sete |
20kVA Transformer 1 sete | |
Reactor | |
Capacitive divider 400kV | |
GDTF-520/260 | |
Matla a kenang (V) | 380 |
Matla a tsoang (kV) | 0-260 |
Bokhoni (kVA) | 520 |
Sebaka sa kopo | 110KV Circuit breaker le bar ea libese |
110kV GIS | |
110kV (300 mm²) mohala oa 800m | |
thapo ya 35kv (300 mm²) 3km | |
10kV (300 mm²) cable 6km | |
110kv e tletseng insulation Transformer | |
Litlhophiso tsa mantlha | 25kW Mohloli o feto-fetohang oa maqhubu 1 sete |
25kVA Transformer e thabisang 1 sete | |
Reactor 65kV/2A 4sets | |
Capacitive divider 300kV | |
GDTF-500/500 | |
Matla a kenang (V) | 380 |
Matla a tsoang (kV) | 0-500 |
Bokhoni (kVA) | 500 |
Sebaka sa kopo | 220kV kapa ka tlase ho CT/PT |
220kV kapa ka tlase ho sehlahla | |
220kV kapa ka tlase Li-insulators, li-disconnectors | |
220kV kapa ka tlase ho Circuit breaker | |
220kV kapa ka tlase ho Insulation Instrument | |
Litlhophiso tsa mantlha | 20kW Mohloli o feto-fetohang oa maqhubu 1 sete |
20kVA Transformer 1 sete | |
Reactor 125kV/1A 4sets | |
Capacitive divider 500kV | |
GDTF-600/600 | |
Matla a kenang (V) | 380 |
Matla a tsoang (kV) | 0-600 |
Bokhoni (kVA) | 600 |
Sebaka sa kopo | 110kV (300 mm²) mohala oa 800m |
thapo ya 35kv (300 mm²) 110m | |
35-220kV GIS, li-transformer, li-insulator | |
Litlhophiso tsa mantlha | 30kW Mohloli o feto-fetohang oa maqhubu 1 sete |
30kVA Transformer e thabisang 1 sete | |
Reactor 120kV/1A 5sets | |
Capacitive divider 600kV | |
GDTF-800/800 | |
Matla a kenang (V) | 380 |
Matla a tsoang (kV) | 0-800 |
Bokhoni (kVA) | 800 |
Sebaka sa kopo | 110kV (300 mm²) mohala oa 800m |
thapo ya 220kv (300 mm²) 500m | |
35-500kV GIS, li-transformer, li-insulators | |
Litlhophiso tsa mantlha | 40kW Mohloli o feto-fetohang oa maqhubu 1 sete |
40kVA Transformer e thabisang 1 sete | |
Reactor 200kV/1A 4sets | |
Capacitive divider 800kV |