GDP-311CAW 3-in-1 SF6 Quality Analyzer
GDP-311PCAW SF6 analyzer ea boleng ba khase ke sesebelisoa se nkehang habonolo se etselitsoeng ho lekanya bohloeki ba khase ea SF6, ntlha ea phoka, sebopeho, litaba tsa CF4 le litaba tsa moea.
-
GDPDS-341 SF6 Motlakase Insulation State Analyzer Comprehensive
Hajoale, boemo ba motlakase oa UHV oa 110KV ho ea holimo bo sebelisa SF6 e kentsoeng ka khase ea GIS e le lisebelisoa tsa mantlha tsa setsi, tlhahlobo ea boemo ba GIS ea ho kenella ka hare e fihlelleha haholo-holo ka mokhoa oa ho lemoha ha karolo e tsoang le mokhoa oa SF6 oa tlhahlobo ea lik'hemik'hale tsa khase lapeng. le kantle ho naha.
-
GDSF-411CPD SF6 Gas Comprehensive Analyzer
Tlhaloso: GDSF-411CPD SF6Gas comprehensive analyzer ke sesebelisoa se nkehang habonolo se etselitsoeng ho lekanya SF6phoka ea khase, bohloeki le sehlahisoa sa ho bola.
-
GDSF-311WPD 3-In-1 SF6 Analyzer ea Khase
GDSF-311WPD (GDSF-411WPD) ke sesebelisoa se loketseng ha ho hlokahala ho hlahloba metsi, ho hloeka le lihlahisoa tsa ho bola ha khase ea SF6.Karolo ea mantlha ea tlhahlobo ea phoka ke li-sensor tsa DRYCAP® tse hlahisoang ke k'hamphani ea Vaisala ea Finland.
-
GDP-713PM SF6 Gas Dew Point Tester (Chilled Seipone Mokgwa)
GDP-713PM Portable Chilled Mirror SF6 Gas Dew Point Tester e etselitsoe ka ho khetheha bakeng sa ho lemoha mongobo o monyane oa khase ea SF6.Motsoako o phethahetseng oa sensor ea phoka ea boleng bo holimo le thekenoloji e bohlale ea taolo ea elektronike e etsa hore e sebelisoe ka katleho tekanyong e nepahetseng ea phoka tlas'a maemo a fapaneng a tikoloho.
Tekanyo ea ntlha ea phoka e itšetlehile ka molao-motheo oa seipone se pholileng.Mouoane oa metsi ka har'a khase e lekantsoeng o koaheloa hore e be metsi kapa serame holim'a seiponeng ka semiconductor e batang ea reactor e pholileng.Ha tekanyo ea mekhahlelo e 'meli ea metsi ka khase e fihla, mocheso oa seiponeng o lekanngoa ka nako ena, ke sebaka sa phoka kapa ntlha ea serame.
Ha ho bapisoa le mefuta e meng ea metara ea phoka, seipone sa phoka se pholileng se lekanya mocheso oa phoka ka mokhoa o nepahetseng haholoanyane, 'me ka nako e ts'oanang se na le litšobotsi tsa ho pheta-pheta hantle ha tekanyo, liphetho tse tsitsitseng le tse ka tšeptjoang tsa tekanyo, le ts'ebetso e bonolo.
GDP-713PM portable cooling method SF6 gas dew point meter ke sesebelisoa se tloaelehileng sa tekanyo ea mongobo masimong a matla a motlakase, khase, meteorology, lisebelisoa tsa elektroniki, petroleum, indasteri ea lik'hemik'hale, tekanyo, joalo-joalo Ke khetho e nepahetseng bakeng sa ho theha maemo a mongobo. sesebelisoa.
-
GDP-8000CM SF6 Gesi Dew Point Tester (Mokhoa oa Seipone se Chilled)
GDP-8000CM Portable Chilled Mirror SF6 Gas Dew Point Tester e etselitsoe ka ho khetheha ho bona SF6 ea mongobo o monyane oa khase o sebelisoang sebakeng sohle sa mocheso oa indasteri ea matla, e ipapisitseng le sehatsetsi sa Stryn le molao-motheo oa ho lekanya seipone se pholileng.
-
GDFJ-311M SF6 Sehlahisoa sa ho Senyeha ha Khase
GDFJ-311M SF6 Gas Decomposition Product Tester ke sesebelisoa se nkehang habonolo se etselitsoeng ho lekanya sehlahisoa sa SF6 sa ho bola ha khase.
-
GDP-311IR SF6 Setekoli sa Bohloeki ba Khase (Mokhoa oa IR)
Teko ea bohloeki ba khase ea GDP-311IR SF6 ke sesebelisoa se nkehang habonolo sa tlhahlobo ea bohloeki ba khase ea SF6 setšeng se ntlafalitsoeng ke k'hamphani ea rona.
-
GDSF-311WP SF6 Dew Point le Purity Tester
GDSF-311WP ke sesebelisoa se loketseng ha ho hlokahala ho etsa liteko tsa metsi le bohloeki ba khase ea SF6.Karolo ea mantlha ke li-sensor tsa DRYCAP tse hlahisoang ke k'hamphani ea Vaisala ea Finland.
-
GDP-8000CM SF6 Gesi Dew Point Tester (Mokhoa oa Seipone se Chilled)
GDP-8000CM Portable Chilled Mirror SF6 Gas Dew Point Tester e etselitsoe ka ho khetheha ho bona SF6 ea mongobo o monyane oa khase o sebelisoang sebakeng sohle sa mocheso oa indasteri ea matla, e ipapisitseng le sehatsetsi sa Stryn le molao-motheo oa ho lekanya seipone se pholileng.
-
GDWS-311RC SF6 Khase Dew Point Tester
GDWS-311RC ke sesebelisoa se loketseng ha ho hlokahala ho etsa tlhahlobo ea metsi a khase ea SF6.Karolo ea mantlha ke li-sensor tsa DRYCAP tse hlahisoang ke k'hamphani ea Vaisala ea Finland.Ka li-chips tsa profeshenale le li-algorithms tsa software tse ntle haholo tsa STMicroelectronics, re hlahisitse moloko o mocha oa sesebelisoa sa tlhahlobo ea mongobo oa khase.