GDP-311CAW 3-in-1 SF6 Quality Analyzer
GDP-311PCAW SF6 analyzer ea boleng ba khase ke sesebelisoa se nkehang habonolo se etselitsoeng ho lekanya bohloeki ba khase ea SF6, ntlha ea phoka, sebopeho, litaba tsa CF4 le litaba tsa moea.
-
GDQC-16A(mini) SF6 Vacuum Pumping le Sesebelisoa sa ho Tlatsa
GDQC-16A Gas Vacuum Pumping and Filling Device e sebelisoa haholo e le lisebelisoa tse thusang tsa lisebelisoa tsa khase GCBT, GIS, SF6 nakong ea ho kenya, ho lokisa le ho lokisa lik'hamphani tse fapaneng tsa phepelo ea motlakase, lik'hamphani tsa boenjiniere ba phetisetso ea matla, lifeme tsa motlakase, phetisetso ea motlakase o phahameng haholo, khase ea SF6. fektheri ea tlhahiso ea lisebelisoa tsa motlakase le mafapha a mang.
-
GDQH-601-50 SF6 Mochini oa ho Hlakola Khase
Moetso oa GDQH-601-50 ke mochini o ikhethileng oa vacuumizing le sesebelisoa sa ho tlatsa.E loketse lisebelisoa tsa motlakase tsa SF6, moetsi oa GIS lelipatlisisosetsi.
-
GDQH-31H Sesebelisoa sa Pholiso ea Khase ea SF6 e nkehang
GDQH-31W Portable SF6 Gas Recovery Device (MINI) e sebelisoa femeng ea tlhahiso ea lisebelisoa tsa motlakase tse kentsoeng ka khase ea SF6 le mafapha a ts'ebetso le lipatlisiso tsa mahlale ho tlatsa lisebelisoa tsa motlakase ka khase ea SF6 le ho khutlisa khase ea SF6 lisebelisoa tsa motlakase tse sebelisitsoeng kapa tse lekiloeng.
Ka nako e ts'oanang, e hloekisoa le ho hatelloa ebe e bolokoa ka tanka ea polokelo.E loketse marang-rang a kabo ea marang-rang a ring ka tlase ho 50kV.
-
GDQH-31W Sesebelisoa sa Pholiso ea Khase ea SF6 e nkehang
GDQH-31W Portable SF6 Gas Recovery Device (MINI) e sebelisoa femeng ea tlhahiso ea lisebelisoa tsa motlakase tse kentsoeng ka khase ea SF6 le mafapha a ts'ebetso le lipatlisiso tsa mahlale ho tlatsa lisebelisoa tsa motlakase ka khase ea SF6 le ho khutlisa khase ea SF6 lisebelisoa tsa motlakase tse sebelisitsoeng kapa tse lekiloeng.
Ka nako e ts'oanang, e hloekisoa le ho hatelloa ebe e bolokoa ka tanka ea polokelo.E loketse marang-rang a kabo ea marang-rang a ring ka tlase ho 50kV.
-
GDWG-IV SF6 Gas Leak Detector(IR Series)
GDWG-IV SF6Gas Leak Detector ke sesebelisoa sa ho lutla sa mofuta o mofubelu oa infrared (NDIR technology).Ke ponts'o ea 'mala oa OLED mme e bonts'a mahloriso a SF6 ka nako ea nnete.
-
GDWG-V SF6 Gas Leak Detector (mofuta oa IR, Pontšo e habeli)
GDWG-V SF6 Gas Leak Detector ke mochine o mofubelu oa mofuta o mofubelu oa infrared (NDIR technology) e nang le pontšo e habeli.Ke pontšo ea mebala ea INCELL TFT mme e bonts'a mahloriso a SF6 ka nako ea 'nete.
-
GDPDS-341 SF6 Motlakase Insulation State Analyzer Comprehensive
Hajoale, boemo ba motlakase oa UHV oa 110KV ho ea holimo bo sebelisa SF6 e kentsoeng ka khase ea GIS e le lisebelisoa tsa mantlha tsa setsi, tlhahlobo ea boemo ba GIS ea ho kenella ka hare e fihlelleha haholo-holo ka mokhoa oa ho lemoha ha karolo e tsoang le mokhoa oa SF6 oa tlhahlobo ea lik'hemik'hale tsa khase lapeng. le kantle ho naha.
-
GDSF-411CPD SF6 Gas Comprehensive Analyzer
Tlhaloso: GDSF-411CPD SF6Gas comprehensive analyzer ke sesebelisoa se nkehang habonolo se etselitsoeng ho lekanya SF6phoka ea khase, bohloeki le sehlahisoa sa ho bola.
-
GDSF-311WPD 3-In-1 SF6 Analyzer ea Khase
GDSF-311WPD (GDSF-411WPD) ke sesebelisoa se loketseng ha ho hlokahala ho hlahloba metsi, ho hloeka le lihlahisoa tsa ho bola ha khase ea SF6.Karolo ea mantlha ea tlhahlobo ea phoka ke li-sensor tsa DRYCAP® tse hlahisoang ke k'hamphani ea Vaisala ea Finland.
-
GLF-314 SF6 Gas Infrared Imaging Leak Detector
SF6 infrared imaging leak detector ke sesebediswa se sa amaneng le kgase ya ho dutla ha kgase se ka kgonang ho lemoha ho dutla ha kgase ka dimithara tse mmalwa kapa mashome a metso.E ka khona ho hlahloba sebaka se seholo sa ho lemoha kapele 'me ea fumana ho lutla ka nepo ka nako ea nnete.
Sets'oants'o sa ho lemoha ha khase se khona ho bona ho lutla kapa ho tsoa ho sa hlophisoeng ha lintho tse feto-fetohang, 'me se ntse se na le ts'ebetso e ntle le bakeng sa ho lutla ha khase e nyane haholo.
Tšebeliso ea ho lemoha ha khase ea khase ke tharollo e sebetsang hantle le e ka tšeptjoang, e ka bonang ho tsoa ha lihlahisoa tsa khase ea tlhaho lihokelong tse fapaneng tse kang lipalangoang, polokelo le tlhahiso, e le ho eketsa polokeho le ho boloka litšenyehelo.
-
GDP-713PM SF6 Gas Dew Point Tester (Chilled Seipone Mokgwa)
GDP-713PM Portable Chilled Mirror SF6 Gas Dew Point Tester e etselitsoe ka ho khetheha bakeng sa ho lemoha mongobo o monyane oa khase ea SF6.Motsoako o phethahetseng oa sensor ea phoka ea boleng bo holimo le thekenoloji e bohlale ea taolo ea elektronike e etsa hore e sebelisoe ka katleho tekanyong e nepahetseng ea phoka tlas'a maemo a fapaneng a tikoloho.
Tekanyo ea ntlha ea phoka e itšetlehile ka molao-motheo oa seipone se pholileng.Mouoane oa metsi ka har'a khase e lekantsoeng o koaheloa hore e be metsi kapa serame holim'a seiponeng ka semiconductor e batang ea reactor e pholileng.Ha tekanyo ea mekhahlelo e 'meli ea metsi ka khase e fihla, mocheso oa seiponeng o lekanngoa ka nako ena, ke sebaka sa phoka kapa ntlha ea serame.
Ha ho bapisoa le mefuta e meng ea metara ea phoka, seipone sa phoka se pholileng se lekanya mocheso oa phoka ka mokhoa o nepahetseng haholoanyane, 'me ka nako e ts'oanang se na le litšobotsi tsa ho pheta-pheta hantle ha tekanyo, liphetho tse tsitsitseng le tse ka tšeptjoang tsa tekanyo, le ts'ebetso e bonolo.
GDP-713PM portable cooling method SF6 gas dew point meter ke sesebelisoa se tloaelehileng sa tekanyo ea mongobo masimong a matla a motlakase, khase, meteorology, lisebelisoa tsa elektroniki, petroleum, indasteri ea lik'hemik'hale, tekanyo, joalo-joalo Ke khetho e nepahetseng bakeng sa ho theha maemo a mongobo. sesebelisoa.