GDYZ-302 Wireless Zinc Oxide Surge Arrester Tester
GDYZ-302 Zinc Oxide Arrester Live Tester ke sesebelisoa se khethehileng se sebelisetsoang ho hlahloba ts'ebetso ea motlakase ea Zinc Oxide Arrester.
-
GD-610B Mofuputsi oa Liphoso tsa Insulator
GD-610B ea mohlala e sebelisetsoa ho bona liphoso tsa li-insulators le ho fumana liphoso setsing sa motlakase, setsing sa motlakase ntle le ho khaola matla.E ka boela ea sebelisoa bakeng sa ho lemoha PD, ho lemoha ha corona discharge, ho sibolloa ha lisebelisoa tsa motlakase.
-
GDJW-40B Wireless Insulator Tester
GDJW-40B e ka sebelisoa ho lekola likhakanyo tsa kabo ea insulator e emisitsoeng e qosoang kapa tlhahlobo ea laboratori ea insulator e emisitsoeng, le ho thusa ho bona ka nepo bothata ba kahare bo patiloeng ba insulator, ho ntlafatsa ts'epahalo ea ts'ebetso ea sistimi ea grid ea matla, le ho ntlafatsa. bokhabane ba ho sebetsa ba basebetsi ba etsang tlhahlobo e phelang.
-
Online Monitoring System bakeng sa Metal Oxide Arrester
Hangata ho na le mekhoa e 'meli ea ho beha leihlo boemo ba ho kenya letsoho ba lisebelisoa tsa motlakase tse phahameng ka har'a li-substations: ho lekola marang-rang le ho lemoha (ho nkehang) inthaneteng.
-
GDUD-PTM Ultrasonic Flaw Detector Bakeng sa Tora ea Matla a Motlakase
Ultrasonic Flaw Detector ke sesebelisoa sa tlhahlobo se sa senyeheng se sebelisetsoang tlhahlobo ea bofokoli ba thepa le sebaka, tekanyo ea botenya ba lebota, joalo-joalo, 'me se loketse lisebelisoa tse fapaneng tse kholo tsa mosebetsi le litlhoko tsa tekanyo e phahameng ea qeto.
-
GDYZ-302W Metal Oxide Arrester (MOA) Tester
GDYZ-302W Metal Oxide Arrester Tester e entsoe ka moamoheli, mohloekisi, le molamu oa insulating.Moamoheli le mohloela ba amohela puisano e se nang mohala, sebaka sa puisano ke limithara tse 30, moamoheli a ka bula kapa a koala hlooho ea motsu ho phethela ts'ebetso ea tlhahlobo, 'me moamoheli a ka bonts'a boleng ba tlhahlobo ea hajoale le boemo ba clamp. hlooho ka nako ea sebele.Mohloli o sebelisa enjene e nyane ho khanna ho bula kapa ho koala hlooho ea clamp.Hlooho ea clamp e entsoe ka permalloy e sebetsang hantle haholo, e nang le bokhoni bo matla ba ho thibela tšitiso ebile ha e amehe haholo ke matla a khoheli a kantle.Qeto e phahame joalo ka 1uA.Sesebelisoa se ka hokeloa le molamu o sireletsang bakeng sa tlhahlobo ea li-surge arresters tsa zinc oxide meleng ea motlakase o phahameng.Metara e ka boela ea sebelisoa e le meter ea hona joale ea ho lutla e phahameng haholo.
-
GDYZ-301 Zinc Oxide Surge Arrester Tester
GDYZ-301 Lightning Arrester Tester ke lisebelisoa tse khethehileng tsa ho hlahloba ts'ebetso ea motlakase ea zinc oxide arrester.E loketse ho lekola maemo a fapaneng a motlakase oa zinc oxide arrester ka motlakase kapa ntle le motlakase, ka hona ho lemoha likotsi tse ka hare ho sesebelisoa tse bakoang ke ho kenngoa ha metsi kapa botsofali ba metal oxide varistor (MOV).
-
GDYZ-301A Zinc Oxide Surge Arrester Tester
GDYZ-301A Automatic Zinc Oxide Surge Arrester Tester e na le mesebetsi e meraro e ka tlase:
Teko ea hona joale e hanyetsanang
Tekanyo ea mithara ea hajoale ea mochini
Counter action test of monitor
-
GDUD-PBI Ultrasonic Flaw Detector bakeng sa Thepa ea Motlakase
Ultrasonic Flaw Detector ke sesebelisoa sa tlhahlobo se sa senyeheng se sebelisetsoang ho bona tšenyo e ka hare ea mochini bakeng sa lisebelisoa tsa motlakase.