GD-2136H Cable Fault Locating System
GD2136H Cable Fault system ke sesebelisoa sa bohlokoa sa ho boloka mefuta eohle ea likhoele.E sebelisa mekhoa e fapaneng ea ho bona ho lekola liphoso tsa cable, tse loketseng maemo a fapaneng a lithapo tsa motlakase le likhoele tsa puisano.
Sistimi e na le likarolo tse latelang:
1. GD-2131H Impulse Jenereithara
2. GD-2132 Cable Fault Locator
3. GD-2133 Cable Fault Tester
4. Lisebelisoa tse ling
Jenereithara ea GD-2131H Impulse Jenereithara
E sebelisetsoa ho hlahisa tšusumetso ea HV ha u sebelisa mokhoa oa flashover oa impulse ho bona phoso e phahameng ea impedance.
●Bokhoni bo matla ba ho chesa, matla a max.burning ke 1000W, ntlha ea ho senya e ka chesoa ka nako e khutšoanyane mme ho hanyetsa ha ntlha ea ho senya ho fokotsehile.
●Haeba o sebetsa 'moho le GD-2133 Cable Fault Tester, ho na le litsela tse peli tsa ho fumana:
a.Low voltage pulse: Haeba feela u sebelisa GD-2133, potoloho e bulehileng le liphoso tse fokolang tsa cable li ka fumanoa, 'me bolelele ba cable bo ka lekanyetsoa kapa lebelo la maqhubu a cable le ka fumanoa.
b.High voltage flashover: The dischaging pulse voltage wave form of fault point e nkuoa ka ho ntša lekhalo la sphere, le ka fumanang sebaka sa phoso.
●Hlahisa tšusumetso ea maqhubu a tsitsitseng.Haeba o sebetsa 'moho le GD-2132 Cable Fault Locator, ho na le mesebetsi e latelang:
a.Mokhoa oa molumo o sebelisoa ho phethela sebaka se nepahetseng sa lintlha tse akaretsang tse hanyetsanang le li-flashover.
b.Ho supa tsela ea thapo, khetha thapo e khethehileng.
c.Bakeng sa ho senyeha ha metallic(dead grounding), ho sebelisa tekanyo ea magnetic field ho fumana sebaka ka nepo.
●E ka boela ea sebelisoa ho DC HV standstand test.
●Matla a kenang: AC 220V, 50Hz
●Matla a tsoang: DC 0-32kV (e ka fetoloang)
●Matla a lekantsoeng: 2000VA
●Max.energy: 2048J, 4uF
●DC flashover voltage: 32kV
●DC Flashover ea hona joale: 63mA
●Max.impulse hona joale: 500mA
●Mokhoa oa ho lahla: DC HV, nako e le 'ngoe, potoloho
●Nako ea ho qeta nako: metsotsoana e 3-6
●Mocheso oa tikoloho: 0-40 ℃
●Mongobo: <75% RH
●Boima: <1000m
●Boemo ba Insulation: A
●Boima: 430 * 540 * 410mm
●Boima ba 'mele: hoo e ka bang 31kg.
Ho kenyeletsoa transmitter, receiver, Inductive probe, monyetla oa ho fumana mofutaframe.E loketse ho leka mefuta eohle ea thapo ea matla ka mokhanni oa tšepe.
Mosebetsi oa eona o ka sehloohong ke ho fumana sebaka se fokolang sa ho kenya letsoho, ho lemoha potoloho lebotebo ba thapo ya matla.
●Boikutlo bo phahameng
●Ho hoholeha ho tlase
●Ho nepahala ho phahameng hoa sebaka
●Khahlanong le tšitiso
●LCD skrine ho bonts'a lets'oao le boemo
●Betri ea Li e hahelletsoeng ka hare
●Sebaka sa ho batla le ho se fumana: thapo ea lehae 3km, thapo e 'ngoe ho fihla ho 20km
●Sebaka sa sebaka sa impedance: 0-5MΩ.
●Ho fumana ho nepahala: ≤± 10cm.
●Botebo ba cable ea ho lemoha: <3m.
E ka leka liphoso tsa flashover e phahameng ea impedance, e tlase haholoresistance grounding, short-circuit, cable disconnection, kgokelo e mpebakeng sa mefuta eohle ea likhoele tsa matla (voltage degree 1kV-35kV),thapo ea lehae, mohala oa puisano, mohala oa coaxial le mohala o ka holimo oa tšepe.
E ka boela ea lekanya bolelele ba cable le lebelo la phatlalatso la lebelo la maqhubu a motlakase holim'a thapo.
●Teko e bolokehileng, e potlakileng le e nepahetseng.E sebelisa mokhoa oa LV impulse le ho lemoha HV flashover, e lekang mefuta eohle ea liphoso tsa cable.Haholo-holo bakeng sa flashover le liphoso tse phahameng tsa impendance tsa lithapo, e ka lekoa ka ho toba ntle le ho chesa;haeba e na le sebaka sa ho metha acoustic, boemo bo nepahetseng ba phoso bo ka khethoa ka nepo.
●Ho sebelisa theknoloji ea sampole ea data e potlakileng.Lebelo la lisampole la A/D ke 100Mhz, ho etsa qeto ea ho bala ea sesebelisoa ke 1m mme sebaka se sa boneng se bonoang ke 1m.
●Foromo ea Wave le data li hlaha ka bo eona skrineng se seholo sa LCD.
●Sebopeho sa wave le polokelo ea parameter, hopola ts'ebetso.
●Mosebetsi oa ho bapisa tlhahlobo ea waveform ea cable fault le waveform e tloaelehileng.
●Mosebetsi oa ho atolosa Wave form.
●Hlahisa ka ho toba ntlha ea phoso le sebaka sa teko sebaka se tobileng kapa sebaka se lekanyelitsoeng.
●Fetola lebelo la phatlalatso ka nako efe kapa efe ho latela likhoele tse fapaneng tsa tlhahlobo.
●Betri e hahelletsoeng ka har'a eona.E nyane, e nkehang habonolo.
●Bolelele ba teko: 15km(Thapo e butsoeng ho fihla ho 100km).
●Ho lemoha ha bofofu: 1m
●Qeto: 1m
●Tšebeliso ea matla: 5VA
●Mocheso oa tikoloho: 0-40℃(moeli o lekanyelitsoeng oa mocheso: -10℃-50℃)
●Mongobo o amanang: 40℃(20℃90)%RH
●Khatello ea sepakapaka: 86-106Kpa
●Boholo: 275 * 220 * 160mm
●Boima ba 'mele: 1.8kg
Lisebelisoa tse ling li kenyelletsa AF Stethoscope, Li-headphones, Grounding Pin, PD Locating Rack, RF Tracking Rod.