GD-4136H Cable Fault Locating System
GD4136H Cable Fault system ke sesebelisoa sa bohlokoa sa ho boloka mefuta eohle ea likhoele.E sebelisa mekhoa e fapaneng ea ho bona ho lekola liphoso tsa cable, tse loketseng maemo a fapaneng a lithapo tsa motlakase le likhoele tsa puisano.
Sistimi e na le likarolo tse latelang:
Sesebelisoa sa 1.GD-2131H Impulse Jenereithara
2.GD-4132 Cable Fault Locator
3.GD-4133 Multi-pulse Cable Fault Detector
4.GD-4133S Multi-pulse Coupler
5.Lisebelisoa tse ling
Jenereithara ea GD-2131H Impulse Jenereithara
E sebelisetsoa ho hlahisa tšusumetso ea HV ha u sebelisa mokhoa oa flashover oa impulse ho bona phoso e phahameng ea impedance.
●Bokhoni bo matla ba ho chesa, matla a maholo a ho chesa ke 1000W, ho senyehantlha e ka chesoa ka nako e khuts'oane mme ho hanyetsa ha ntlha ea ho senyeha hoa fokotseha.
●Haeba o sebetsa 'moho le GD-4133 Cable Fault Tester, ho na le litsela tse peli tsa ho fumana:
a.Low voltage pulse: Haeba feela u sebelisa GD-4133, potoloho e bulehileng le liphoso tse fokolang tsa cable li ka fumanoa, 'me bolelele ba cable bo ka lekanyetsoa kapa lebelo la maqhubu a cable le ka fumanoa.
b.High voltage flashover: The dischaging pulse voltage wave form of fault point e nkuoa ka ho ntša lekhalo la sphere, le ka fumanang sebaka sa phoso.
●Hlahisa tšusumetso ea maqhubu a tsitsitseng.Haeba o sebetsa 'moho le GD-4132 Cable Fault Locator, ho na le mesebetsi e latelang:
a.Maqhubu a molumo: fumana litšitiso tse phahameng, liphoso tsa flash-over.
b.Ho supa tsela ea thapo, khetha thapo e khethehileng.
c.Ho senyeha ha metallic(dead grounding), ho sebelisa tekanyo ea matla a khoheli ho fumana sebaka ka nepo.
●E ka boela ea sebelisoa ho DC HV standstand test.
●Matla a kenang: AC 220V, 50Hz
●Matla a tsoang: DC 0-32kV (e ka fetoloang)
●Matla a lekantsoeng: 2kVA
●Max.energy: 2048J, 4uF
●DC flashover voltage: 32kV
●DC Flashover ea hona joale: 63mA
●Max.impulse hona joale: 500mA
●Mokhoa oa ho lahla: DC HV, nako e le 'ngoe, potoloho
●Nako ea ho qeta nako: metsotsoana e 3-6
●Mocheso oa tikoloho: 0-40 ℃
●Mongobo: <75% RH
●Boima: <1000m
●Boemo ba Insulation: A
●Boima: 430 * 540 * 410mm
●Boima ba 'mele: hoo e ka bang 31kg.
Ho kenyeletsoa yuniti ea mantlha, sensor ea acoustic le makenete, li-headphone tse thibelang lerata le tjhaja.
E loketse ho leka mefuta eohle ea thapo ea matla ka mokhanni oa tšepe.
Mosebetsi oa eona o ka sehloohong ke ho fumana sebaka se fokolang sa ho kenya letsoho, ho lemoha potoloho le botebo ba thapo ea matla.
●Acoustic Magnetic e amohela ka nako e le 'ngoe.
●Bokhoni bo matla ba ho thibela tšitiso.
●Ka li-headphone tse thibelang lerata.
●Pontšo ea 320 * 240 LCD skrineng.
●E hahelletsoeng ka har'a betri ea Li-betri, e nang le tjhaja e potlakileng.
●Pontšo ea waveform ea acoustic le Magnetic, pontšo le lerata li bonolo ho khetholla.
●U sebelisa sesupa ho lekanya ho lieha hoa acoustic le makenete, fumana ka nepo ntlha ea phoso.
●Ho ea ka polarity ea pele ea magnetic.waveform, e ka fumana le ho lemoha tsela.
1. Ho fumana mosebetsi
a.Sehlopha sa phetisetso ea lets'oao la acoustic: frequency frequency 400Hz, bandwidth 200Hz
b.Phaello ea matšoao: 80dB
c.Ho nepahala ha sebaka: 0.1m
2.Phepelo ea Matla
a.E hahiloeng ka har'a Li-betri, motlakase oa lebitso 7.4V, matla a 3000mAH.
b.Tšebeliso ea matla: 300mA, nako e tsoelang pele ea ho sebetsa 9hours.
c.Chaja: kenya AC220V±10%, 50Hz.Phallo ea lebitso 8.4V, DC 1A
d.Nako ea ho tjhaja: 4hours
3. Boemo: 270mm * 150mm * 210mm
4. Boima ba 'mele: 1.5kg.
5. Sebelisa boemo
Mocheso -10 ℃--40 ℃, mongobo 5-90%RH, bophahamo ba <4500m
GD-4133 Cable Fault Detector e sebelisoa ho metha
sebaka pakeng tsa liphoso tsa cable.Ho bonolo ho
sebetsa le ka segokanyimmediamentsi sa sebolokigolo.
E ka sebelisoa e le mong tlas'a mokhoa o tlaase oa motlakase oa pulse.U
tlas'a mokhoa oa pulse current, e hloka ho sebetsa le GD-2131
jenereithara e phahameng ea motlakase. Tlas'a mokhoa oa ho otla ka bongata, GD-4133S
coupler e lokela ho sebetsa hammoho.Kamora ho fumana sebaka se hole, sebaka sa liphoso sa GD-4132 se lokela ho sebelisoa bakeng sa ho supa phoso.Lihlahisoa tsena li ka kopanngoa ho
sete ea ts'ebetso e phahameng le sistimi e ncha ea tlhahlobo ea phoso ea cable.
●7inch LCD skrine, botsoalle segokanyimmediamentsi sa sebolokigolo.
●Mekhoa e mengata ea ho fumana sebaka:
Mokhoa o tlase oa pulse: o loketse ho fumana phoso e tlase ea ho hanyetsa, phoso ea potoloho e khuts'oane, phoso ea potoloho e bulehileng.E ka boela ea sebelisoa ho lekanya bolelele ba thapo, manonyeletso a mahareng, manonyeletso a T, le kopanelo ea ho emisa mohala.Mokhoa ona o ka boela oa sebelisoa ho lokisa lebelo la maqhubu.
Mokhoa oa hona joale oa Pulse: E loketse tekanyo ea sebaka sa phoso e phahameng ea ho hanyetsa, phoso ea ho senyeha.Ho sebelisa coupler ea hona joale ho bokella matshwao ho tswa ho terata ya lefatshe, e etsa hore mosebedisi a be hole le matla a phahameng.Mokhoa ona o bolokehile ebile o ka tšeptjoa.
Multiple pulse/ Ketso ya ho otlana: tsela e tsoetseng pele ya ho metha sebaka.Ho bonolo ho khetholla sebopeho sa wave 'me ho nepahala ho phahame.
●200MHz sampole ea nako ea nnete.Max.0.4m tekanyo qeto.E na le sebaka se senyane se shoeleng 'me e khethehile bakeng sa thapo e khuts'oane le thapo e haufi ea fault.
●Thetsa skrine ebe o tobetsa konopo ea ts'ebetso
●PIP kopi (setšoantšo.polokelo ea nakoana)
Ho tla ba le fensetere e kholo 'me lifensetere tse tharo tsa polokelo ea nakoana li ka sheba mefuta e meraro ea maqhubu hammoho.
●Sistimi ea ts'ebetso e hahiloeng kahare
Tsamaiso e khethehileng ea software bakeng sa ho ntlafatsa, ho boloka le ho tsosolosa software.
●Mosebetsi oa sekala
Sebaka sa ho qala, likhokahano tse 10, phoso e le 'ngoe ea cable le bolelele bo le bong bo felletseng li ka beoa.
Bontša sekhahla le sebopeho sa wave sa liteko hammoho
●Waveform polokelo le puisano le khomphuta.
Polokelo ea ka hare ea maqhubu a maqhubu.
Ka USB, ho jarolla kapa ho kenya data
Puisano le khomphuta
●Tsamaiso ea matla
Leseli le ka morao lea fokola haeba ho se ts'ebetso ka mor'a 2mins 'me le tima ka mor'a 10mins haeba ho se na ts'ebetso.
Betri e hahiloeng ka har'a Polymer Lithium-ion.
Nako ea ho sebetsa e fihla ho lihora tse 5 bakeng sa tšebeliso ka 'ngoe.
Nyeoe e matla, e bonolo ho e jara.
Mekhoa ea ho fumana sebaka | Mokhoa o tlase oa motlakase oa motlakase Mokhoa oa hona joale oa Impulse Mekhoa e mengata ea tšusumetso haeba e tsamaisana le GD-4133S |
Max.Sampling frequency | 200MHz |
Fumana mefuta | 0-70dB |
Matla a tlase a matla a motlakase | 30V |
Qeto | 0.4m |
Max.Sebaka sa sebaka | 100km |
Sebaka se shoeleng | 2m |
Betri | Nickel-metal hydride rechargeable libetri, nako ea mamello ho feta lihora tse 5 |
Khokahano ea puisano | USB |
Phepelo ea motlakase | Kenya AC220V, 50Hz, 2A ea hajoale, tjhaja lihora tse 8 |
Lefifi. | 274×218×81mm |
Boima ba 'mele | 3.5kgs |
Mocheso oa ho sebetsa | -10 ℃-40 ℃ |
Mongobo | 5-90%RH |
Phahamiso | <4500m |
E sebetsa 'moho le GD-4133 Cable Fault Detector,e sebelisetsoa ho bona phoso e phahameng ea ho lutla, phoso ea flashover,lefats'e le tlase la impedance le phoso e bulehileng ea lithapo tsa motlakase.
GD-4133S e fane ka lets'oao la ho kopanya pulse bakeng sa GD-4133 lee arole lisebelisoa tse phahameng tsa motlakase.
●Ho sebelisa thekenoloji e tsoetseng pele ka ho fetisisa ea ho leka-lekana ha multiple pulse le pulse.Leqhubu le bonts'itsoeng le bonolo ho le tseba.
●Ka ts'ireletso ea HV e sireletsehileng, potoloho ea ho lekanya le matla a phahameng a matla a motlakase a arotsoe ka motlakase.
●Wiring e bonolo, e bolokehile ebile e ka tšeptjoa.
●Pulse voltage: 300V (PP)
●Voltage e lumellehang ea ho kenya: <35kV
●Matla a kenang a lumelletsoeng: <2000J
●Kenyelletso ea matla: 220V AC, 50Hz
●Boima: 560 * 230 * 220mm
●Boima: 7kg.