GD-7018A Optical Fiber Identifier
The GD-7018 series optical fiber pipeline identifier e ka fumana le ho lekanya botebo ba liphaephe tse ka tlas'a lefatše, lithapo le likhoele tsa optical tlas'a boemo ba ntle le ho cheka, 'me ka nepo li fumane lintlha tse senyehileng tsa lesela la kantle la liphaephe tse ka tlas'a lefatše le sebaka sa lintlha tsa phoso tsa cable ka tlas'a lefatše.Sesebelisoa se kenyelletsa mahlale a tsoetseng pele haholo joalo ka filthara ea "ultra-narrow band", puisano e se nang mohala ea Bluetooth, boemo ba GPS, 'mapa oa data o ikemetseng ka software ea tlhahlobo ea data le tlhahiso ea othomathike ea litlaleho tsa liteko.Ho lemoha le ho hlahloba mefuta e fapaneng ea lipeipi tsa tšepe, tsamaiso le tlhokomelo ea liphaephe, moralo le kaho ea masepala, tlhahlobo ea lipeipi tsa phepelo ea motlakase le mafapha a mang ke e 'ngoe ea lisebelisoa tse hlokahalang bakeng sa likarolo tsa tlhokomelo ea lipeipi.
(1) Mesebetsi e mengata
1. Ts'ebetso ea Transmitter: E na le mekhoa e meraro ea ts'ebeliso ea matšoao ea mokhoa oa induction, mokhoa o tobileng le mokhoa oa clamp, o loketseng liketsahalo tse fapaneng.
2. Ts'ebetso ea moamoheli: E sebelisoa ho lekanya sebaka, tataiso, botebo ba lepato le mokelikeli oa liphaephe le likhoele tse ka tlas'a lefatše.
3. Metsu e behang ka ho le letšehali le ka ho le letona e bontša sebaka sa pipeline e lebisitsoeng, 'me sebaka sa sebaka se potlakile ebile se nepahetse;metsu e ka pele le e ka morao le boleng ba dB bo bontša sebaka le boholo ba sebaka sa tšenyo ea lera le thibelang ho bola.
4. Ka ts'ebetso ea backlight, e loketseng bakeng sa pholoso ea tšohanyetso bosiu.
5. Mosebetsi oa ho beha sebaka sa GPS, 'mapa oa liphaephe oa othomathike.
6. Software ea setsebi sa tlhahlobo ea data, tlhahiso e itekanetseng ea tlaleho ea teko.
7. Mesebetsi e ikhethang ea moamoheli oa 7018E: E sebelisetsoa ho fumana liphoso (ho hloleha ha lipeipi ho bolela ho senyeha ha lera le ka ntle la anti-corrosion, ho hloleha ha cable ho bolela ho senyeha ha lera le sireletsang ka ntle), le ho lemoha tšenyo ea ho senya. ea liphaephe tse ka tlas'a lefatše.
8. Tekanyo ea hona joale: lekanya hona joale ho sebelisoa ke transmitter ho pipeline tlas'a teko.
9. Mosebetsi oa Multimeter: o ka lekanya motlakase o tsoang, motlakase oa mohala, mohala oa mohala, impedance le matla.Lekola tsoelo-pele le boleng ba ho kenya letsoho pele le ka mor'a ho batla phoso ea cable.
10. Letlapa la ho kenya ka ntle: le loketse sebaka seo lets'oao le ke keng la kopanngoa ka ho toba ha le lemoha mohala.
(2) Ho nepahala ha boemo bo phahameng
1. Mefuta e fapaneng ea litekanyo bakeng sa boemo ba liphaephe (mokhoa oa phula, mokhoa oa tlhōrō, mokhoa o pharaletseng oa tlhōrō, mokhoa oa tlhōrō ea motsu) o ka netefatsoa ka bobeli ho netefatsa ho nepahala ha boemo ba lipeipi.
2. Mokhoa o phahameng ka ho fetisisa: mokhoa oa tlhōrō, mokhoa o pharaletseng oa tlhōrō, mokhoa oa motsu oa tlhōrō o ka sebelisoa ho lekanya phetoho ea motsoako o otlolohileng ((HX)) kapa gradient e otlolohileng (△HX), le ho fumana ho ea ka boemo ba boleng ba eona bo phahameng;
3. Mokhoa o fokolang: Sebelisa mokhoa o ka tlaase ho fumana boemo ba boleng ba bonyane ka ho lekanya phetoho ea karolo e otlolohileng (HZ).
(3) Ho na le mekhoa e mengata ea molumo
1. Mefuta e fapaneng ea mekhoa ea ho lemoha e ka khethoa ka mokhoa o ikemetseng 'me e ka netefatsoa ka bobeli.
2. Mokhoa oa ho bala ka ho toba ka likhoele tse peli tse rapameng.
3. Mokhoa o le mong oa coil 80%, mokhoa oa 50%.
4. 45 mokhoa oa likhato.
(4) Khahlanong le tšitiso e matla
1. Mekhahlelo e mengata ea ho shebella: ka bobeli motsoako o otlolohileng (HX), motsoako o otlolohileng (HZ) le gradient e otlolohileng (△HX) e ka lekanyetsoa.
2. Matla a ho fetisa a phahameng: Matla a tsoang ho transmitter a fihla ho 10W 'me a lula a fetoha.E ka khethoa ka boikhethelo ho latela litlhoko.
3. Maqhubu a mangata a ho sebetsa:
Khafetsa ea transmitter: 128Hz, 512Hz, 1KHz, 2KHz, 8KHz, 33KHz, 65KHz, 83KHz.
Khafetsa ea ho amohela: seea-le-moea, 50Hz, 100Hz, 512Hz, 1KHz, 2KHz, 8KHz, 33KHz, 65KHz, 83KHz.
4. Ho ea ka litšoaneleho tsa phaephe e reretsoeng (thepa, sebopeho, botebo bo patiloeng, bolelele, joalo-joalo), khetha nako e loketseng ea ho sebetsa.
(5) Ho sebetsa habonolo
1. Intuitive: Pontšo ea litšoantšo e sebelisetsoa ho tsoela pele le ka nako ea sebele ho bonts'a mekhahlelo e sa tšoaneng le matla a pontšo nakong ea ts'ebetso ea ho lemoha.
2. Ka ho iketsa: Fetola ka mokhoa o itekanetseng ho mokhoa oa li-antenna tse peli 'me u fetole ka mokhoa o itekanetseng ho utloahala ha moamoheli ha u lekanya botebo, e le hore u finyelle pontšo e ntle ka ho fetisisa ea ho lekanya,' me u khutlele ka mokhoa o itekanetseng mokhoa oa ho sebetsa pele u qeta.
(6) Nako e telele e tsoelang pele ea ho sebetsa le litšenyehelo tse tlaase tsa tšebeliso
Transmitter e na le pakete e kholo ea lithium battery pack, e ka finyellang litlhoko tsa phepelo ea motlakase ea letsatsi le le leng la tšimo bakeng sa ho lemoha tšimo ka tefiso e le 'ngoe,' me e ka sebelisoa hape, e leng ho fokotsang haholo litšenyehelo tsa ho lemoha.
(7) Transmitter --AC le DC tse sebelisoang habeli
Maemong a tloaelehileng, haeba betri ea transmitter e tletse, sebelisa sephutheloana sa betri se hahelletsoeng kahare ho fana ka matla.Haeba nakong ea ts'ebeliso, betri ea transmitter e le tlase, empa mosebetsi oa ho lemoha ha o e-s'o phethoe, o ka hokahanya ka ho toba adaptara ea matla e inehetseng, sesebelisoa se ka sebelisoa ka tloaelo, ntle le ho emela hore sesebelisoa se qosoe ka botlalo pele se sebelisoa.
Tekheniki Parameter | Aletoto | Bletoto | Cletoto | Dletoto | Eletoto |
Maqhubu a ho Fumana | 5 | 6 | 7 | 8 | 10 |
Khafetsa | 512,1K,33K,83K | 512,1K,33K,83K | 512,1K,33K, 83K | 512,1K,33K,65K,83K | 512, 1K, 2K, 33K, 65K, 83K |
Maqhubu a Patsi | 50Hz | 50Hz 100Hz | 50Hz 100Hz radio | 50Hz 100Hz radio | 50Hz 100Hz radio |
Sefe ea Matla | × | × | √ | √ | √ |
Maqhubu a Phoso | × | × | × | × | 2 |
Ho fumana phoso | × | × | × | × | √ |
Betri ea lithium ion | √ | √ | √ | √ | √ |
A Frame | × | × | × | × | √ |
Ho fumana botebo(m) | 6 | 6 | 6 | 6 | 6 |
Polokelo ea data | × | × | × | √ | √ |