GDKH-12 Motlakase oa Battery ea Lead Acid
Sesebelisoa ke sesebelisoa se ikhethileng bakeng sa ho kenya betri ea lead-acid e laoloang ke valve e nang le matla a betri a 2V, 6V, kapa 12V le bokhoni ba morao ka lebaka la crystallization ea sulfide ea poleiti ea electrode.Ka "activation" le "check discharge", "automatic charger" le mesebetsi e meng ea betri.
Thepa ena e amohela melaoana ea hajoale ea tlhahlobo e tsoetseng pele ea tlhahlobo, 'me e entse letoto la likhatelopele lipatlisisong le ts'ebelisong ea mahlale a macha, lisebelisoa tse ncha, lisebelisoa tse ncha le lits'ebetso tse ncha.E ka etsa liteko tsa ho ntša cheke bakeng sa boemo ba 'nete ba libeteri tse fapaneng tse khutlelang morao,' me mehato e meraro ea ho tjhaja othomathiki kapa li-cycle tse ngata li behiloe ho tjhaja le ho ntša betri ka makhetlo a mangata, e le hore thepa e sebetsang e hlōlehang ho sebetsa poleiti ea betri e kenngoe hape, 'me matla a betri e ka morao a eketseha.E boetse e na le software ea ts'ebeliso ea PC ho kenya data e bokelletsoeng komporong bakeng sa litlhahlobo tse fapaneng.
Sesebelisoa se na le matla a phahameng, boholo bo nyane, boima bo bobebe, le software e felletseng ea taolo ea data bakeng sa komporo e amohelang.Sehokelo sa tšebelisano se bonolo le se bonolo sa tšebeliso ea motho le mochini se fokotsa haholo mosebetsi oa letsatsi le letsatsi oa tlhahlobo le tlhokomelo ea betri mme ke mothusi ea molemo ka ho fetisisa bakeng sa tlhokomelo ea betri.
●Sesebelisoa se amohela ts'ebetso ea skrineng sa touch, mme sebopeho se ka sebetsoa ka kotloloho ho sebelisa pene ea ho ama kapa monoana.Ho na le mekhoa e 'meli ea ho boloka data: polokelo ea kahare le polokelo ea karete ea SD kantle.
●E na le matla a mangata, a fetelletseng hona joale, ho futhumatsa ho feta tekano le mesebetsi e meng ea ts'ireletso.
●Tshebetso ya ho kenya tshebetsong: Ha betri e le offline, betri e le nngwe e ka kenngwa tshebetsong.Pele o kenya ts'ebetsong, beha palo ea lipotoloho tsa ts'ebetso, tefiso e le 'ngoe ea ts'ebetso le nako ea ho qeta nako, matla a tšireletso le li-parameter tse ling, sesebelisoa se tla iketsetsa mosebetsi oa ho kenya;le ho bonts'a matla a betri, tjhaja / ho lahla hona joale, matla a ho tjhaja / ho lahla, nako ea ho tjhaja / ho lahla le lintlha tse ling ka nako ea nnete;Kamora hore potoloho ea ts'ebetso e seng e phethetsoe kapa ts'ebetso e felisoe ka letsoho, ts'ebetso ea ts'ebetso e ka emisoa.
●Ts'ebetso ea ho lahla: Ha betri e le sieo inthaneteng, sebelisa mojaro o bohlale oa bohata ho etsa tlhahlobo e sa khaotseng ea tlhahlobo.Beha "discharge current", "discharge time", "discharge capacity", "termination voltage" le li-parameter tse ling, 'me sesebelisoa se tla iketsetsa mosebetsi oa ho ntša, pontšo ea nako ea sebele ea hona joale, matla a betri, matla a betri, nako ea ho qeta nako. le lintlha tse ling;ha betri e fihla maemong a seng a behiloe a ho emisa kapa ho emisa ts'ebetso ka maiketsetso ho ka emisa tlhahlobo ea ho tsoa.
●Tshebetso ya ho tjhaja: Ha betri e phaphametse inthaneteng kapa e le sieo inthaneteng, betri e ka tjhajwa ka bo yona.Beha li-parameter tse kang "charging current", "charging time", le "termination voltage", 'me sesebelisoa se tla iketsetsa mosebetsi oa ho tjhaja.'Me ponts'o ea nako ea sebele ea ho tjhaja hona joale, matla a betri, matla a betri, nako ea ho tjhaja le lintlha tse ling, ha betri e fihla maemong a ho tjhaja a seng a ntse a behiloe kapa ho felisoa ha ts'ebetso ka maiketsetso ho ka emisa ho tjhaja.
●Ts'ebetso ea tlhahlobo e potlakileng ea ho hanyetsa ka hare: (ka boikhethelo) ka mor'a hore pakete ea betri e lokolloe tsamaisong, ho nka metsotso e 1 ho isa ho e 2 feela ho lekanya matla a ho lekanya betri, ho hanyetsa ka hare, joalo-joalo.
●Skrine sa LCD sa mebala e khanyang haholo.
●Software ea taolo ea data ea komporo e amohelang e matla ebile e mosa.E fana ka taolo ea data, khatiso, tlhahlobo, lipalo-palo tsa tlaleho, tlhahiso ea tlaleho ea tlhahlobo ea othomathike le mesebetsi e meng.
Mofuta o le mong oa selekanyo sa motlakase oa sele | 2V/6V/12V |
Lethathamo la selekanyo sa motlakase o le mong | 2V: 0~3V 6V/12V: 0~16V |
Qeto ea motlakase oa sele e le 'ngoe | 2V: 0.001V;6V/12V: 0.001V |
Ho nepahala ha tekanyo ea motlakase | 0.5% |
Ho lefisa / ho ntša sebaka sa hajoale | 2V: 1A~100A 6V: 1A~ 30A 12V: 1A~ 30A |
Ho lefisa / ho lahla ho nepahala ha taolo ea hajoale | 1% |
Sebaka sa ho lekola boholo ba betri | 2V: 20Ah ~ 1000Ah 6V: 20Ah ~ 300Ah 12V: 20Ah ~ 300Ah |
Matla a sebetsang | AC 220±15% |
Phetiso ea mocheso | Pholiso ea moea e qobelloang |
Tikoloho ya mosebetsi | Mocheso: 0 ℃ ~ 40 ℃ mongobo: 20% ~ 80RH |
Maemo a polokelo | -20 ℃ ~ + 70 ℃ polokelo e pakiloeng |
Pontšo | Leseli la LCD le khanyang haholo |
Boemo | 401mm * 176mm * 273 limilimithara |
Boima ba 'mele | 15kg |