GDBT-8610P Battery Impedance Tester
GDBT-8610P Battery Tester e sebelisoa haholo libakeng tse latelang:
● Telecom: Ofisi e Bohareng, litsi tsa ho sebetsana le data le Libaka tse Hole
● Tšebeliso ea Matla: Switchgear, Power Station le Power Plant
● Mekhatlo ea Lichelete: Litsi tsa Boitsebiso ba K'hamphani
● Petrochemical: Mekhoa ea ho laola mekhoa
● Li-platform tsa Offshore
● 'Muso: Sebaka le libaka
● Litsi tsa Ts'ebetso ea Lekhetho le Lekeno
● Tšireletso ea Lehae, Likolo, Sesole le Sesole sa Metsing
● Mehaho ea Sesole sa Moeeng, Mekhatlo ea Mollo le Sepolesa
●Sistimi ea UPS ea sepetlele
● Bafani ba likoloi tsa motlakase
● Baetsi ba betri ea SLA
● Mefuta e mengata ea teko: 5 ~ 6000Ah, e lumellana le sele e le 'ngoe ea 1.2V, 2V, 6V le 12V
●Sesebediswa se tshwerweng ka letsoho se bohlale le se nkehang habobebe, se matsutla-tsutla ebile ho bonolo ho se tsamaisa
●Skrine sa ho thetsa se mebala-bala se nang le lisebelisoa tsa boikhethelo tsa keyboard
● Teko ka nako e le 'ngoe bakeng sa motlakase, ho hanyetsa le ho hakanngoa bokhoni ba libeteri
● Tekanyo ea Inthaneteng, ha ho hlokahale hore u tlose betri le khoele ho tloha tsamaisong ea eona bakeng sa tlhahlobo, e sireletsehileng le e loketseng
● Teko e potlakileng ea betri le likhoele ka metsotsoana ka ho boloka data ka boiketsetso
● Tšitiso e matla ea ho thibela ho kena-kenana ka nako e phahameng e nang le ts'ebetso e tsitsitseng le e nepahetseng
● Maqhubu a ho lekola a ka tlase ho 10 Hz, ho qoba tšitiso ea capacitive ea betri ka boeona
● USB drive e tobileng bakeng sa ntlafatso ea software le phetiso ea data ho PC bakeng sa tlhahlobo e eketsehileng
● Software e matla ea taolo ea PC, e loketseng ho boloka le ho hlahlobisisa data
● Khopotso e kholo ea ho lekola polokelo ea data ea lisele tse fetang 3000
● Mosebetsi oa Alarm ea Buzzer le ts'ireletso e fetang ea motlakase, e sireletsehileng ho sebelisoa
● Ts'ebetso ea ho lekanya ka boits'oaro pele ho etsoa tlhahlobo, e ntlafatsa ho nepahala ha tlhahlobo
● Mosebetsi oa ho hlahloba hape le oa matšeliso: ts'ebetso leha e le efe e fosahetseng kapa ho siuoa ho ka hlahlojoa hape ka ho tobetsa hanngoe feela
●Boitsebiso bo hlahang ka har'a memori bakeng sa papiso ea tlhahlobo ea hau, le litšupiso tse itlhalosang li fumaneha
Boemo ba ho hanyetsa | 0.00mΩ ~ 100mΩ | Sebaka sa motlakase | 0.000V ~16V* |
Qeto e nyane ea teko-Palo ea li-volts -ho hanyetsa
| 1 mv 0-999μΩ: 1 μΩ 1-9mΩ: 10μΩ(0.01mΩ) 10-99mΩ: 100 μΩ(0.1mΩ) | Ho nepahala ha teko -voltage -ho hanana
| ± 0.2%rdg ±6dgt 0μΩ-250μΩ: 8%±6DGT 250μΩ-500μΩ: 3%±6DGT 500μΩ-100mΩ: 1%±6DGT |
Phepelo ea motlakase | 7.2V 2400mAhBetri ea Li-ion | Nako ea ho sebetsa | Ho feta lihora tse 5 kamora tefiso e felletseng |
Ho lekanya memori ya data | 3000 lisele | Tikoloho ea ts'ebetso | 0 ℃ ho isa ho 40 ℃90% RH |
Pontšo ea LCD | 320 * 240 pixel TFT touch screen | Boemo(yuniti e kholo) | L210*W110*H60 limilimithara |
Boima bo kahare(sephutheloana) | 2 kg | Com port | USB e nyane |