GDP-311CAW 3-in-1 SF6 Quality Analyzer
GDP-311PCAW SF6 analyzer ea boleng ba khase ke sesebelisoa se nkehang habonolo se etselitsoeng ho lekanya bohloeki ba khase ea SF6, ntlha ea phoka, sebopeho, litaba tsa CF4 le litaba tsa moea.Karolo ea mantlha e nang le sensor ea NDIR e hlahisoang ke k'hamphani ea sensor ea Europe ho lekola bohloeki ba khase ea SF6, sensor ea RC e hlahisoang ke Vaisala, Finland ho leka phoka ea phoka, sensor ea NDIR e hlahisoang ke Smartgas, Jeremane ho leka sehlahisoa sa ho bola ha khase ea SF6 - CF4.sensor ea moea e sebelisa theknoloji ea itg.Ntle le moo, re boetse re amohela li-chips tsa profeshenale le li-algorithms tsa software tse ntle haholo tsa STMicroelectronics.
●SF6 tlhahlobo ea tsamaiso ea matla
●Teko ea boleng ba khase ea SF6 cylinder gas
●Teko ea boleng ba khase ea SF6 bakeng sa ho hlaphoheloa le ho sebelisoa hape
●Tlhahiso e phahameng ea khase e hloekileng
●Phepelo ea khase e omileng indastering ea semiconductor
●Tšebeliso ea lipatlisiso le nts'etsopele
●Ka sensor ea boleng bo holimo e tsoang kantle le ts'ebetso ea ho itekanya, liphetho tsa liteko li nepahetse selemo ho pota.
●Ka moralo oa thepa ea polymer ho pholletsa le lipeipi tsa khase ho tloha Legris, Camozzi le Swagelok, etsa bonnete ba hore ha ho na boemo ba ho khomarela lebota, le lebelo la tlhahlobo le potlakileng.
●Valve e laolang tšepe e sa hloekang e se nang oli e amoheloa ho netefatsa ho nepahala ha tlhahlobo.
●Algorithm e tsoetseng pele ea software e ntlafatsa ho nepahala ha liteko tsa li-sensor tse tsoang kantle ho naha.
●Ka tlhophiso ea linyeoe tse feto-fetohang.Mosebelisi a ka kopanya likarolo tse setseng habonolo.
●Matla a ho lemoha, ha ho hlokahale ho oscillation.
●Phetoho ea mocheso le tokiso ea data ea khatello.
●Theknoloji ea khomphutha e makatsang.
●Sistimi ea phepelo ea matla a matla a phahameng a lithium e ka khona ho fana ka matla a mabeli a AC DC.Ha ho na tlhoko ea phepelo ea motlakase ea AC setšeng.Betri ea lithium e ka sebetsa ka nako e telele ho feta lihora tse 8 feela.
●Moralo oa potoloho ea tšitiso ea anti-electromagnetic, ho netefatsa ho ts'epahala ha lihlahisoa.
●Puisano ea USB, likhokahano tsa serial le li-module tsa puisano tse se nang mohala li ka atolosoa ho hlokomela puisano ea PC le mesebetsi ea khatiso.(ka boikhethelo)
●Polokelo ea bongata, e ka hlokomelang mosebetsi oa polokelo oa lihlopha tse 1000 tsa data.
●Ts'ebetso ea ts'ebetso ea pele ea khase e ka hloekisa liphaephe tsa tlhahlobo pele ho ts'ebetso ea tlhahlobo ea tšimo, e khutsufatsang nako ea tlhahlobo.(ka boikhethelo)
●Ka ts'ebetso ea ts'ireletso ea tikoloho.Sesebelisoa se na le ts'ebetso ea tlhahlobo ea khase, e ka sebelisang khase e lekantsoeng ea sulfur hexafluoride.(ka boikhethelo)
●Ho nepahala ha tekanyo ea bohloeki ke 0.5% ka botlalo, e ka sebelisoang ho lekanya khase e phahameng ea SF6 le khase ea 70% SF6.
●Pontšo ea sebaka se setle ka ho fetisisa sa phallo ea teko e hlakile ebile e utloahala.Basebedisi ba ka fetola phallo ea khase ka ho toba le ka potlako.
●Mohaho o kenang moeeng o amohela moralo oa motsoako o monyenyane oa ho itšireletsa, kahoo tsela e lekantsoeng ea moea e ke ke ea tsoa ha e robeha.