GDP-311IR SF6 Setekoli sa Bohloeki ba Khase (Mokhoa oa IR)
Teko ea bohloeki ba khase ea GDP-311IR SF6 ke sesebelisoa se nkehang habonolo sa tlhahlobo ea bohloeki ba khase ea SF6 setšeng se ntlafalitsoeng ke k'hamphani ea rona.Sensor ea tlhahlobo ea khase ea infrared SF6 e entsoeng ke European Sensor Company e sebelisetsoa ho leka bohloeki ba khase ea SF6.Ka li-chips tsa profeshenale le li-algorithms tsa software tse ntle haholo tsa STMicroelectronics, re hlahisitse moloko o mocha oa SF6 ea ho hloekisa khase.
●Tlhahlobo ea bohloeki ba thepa ea motlakase ea khase ea SF6 bakeng sa matla a motlakase
●Teko ea boleng ba khase ea SF6 cylinder gas
●Teko ea boleng ba khase ea SF6 bakeng sa ho hlaphoheloa le ho sebelisoa hape
●Tlhahiso e phahameng ea khase e hloekileng
●Phepelo ea khase e omileng indastering ea semiconductor
●Tšebeliso ea lipatlisiso le nts'etsopele
●Tlhokomelo ea kamore e hloekileng / ntlo e omileng
●Li-sensor tsa boleng bo holimo tse tsoang kantle tse nang le ts'ebetso ea ho itekanya, li netefatsa botsitso le ts'epahalo ea data ea ho lemoha bohloeki selemo ho pota.
●Tsela eohle ea khase e nang le moralo o phahameng oa polymer, e netefatsa hore ha ho na lerako le leketlileng la metsi mme e netefatsa lebelo la tlhahlobo.
●Valve e laolang 'mele oa tšepe e se nang oli e se nang oli e sebelisoa ho netefatsa ho nepahala ha boleng bo lekantsoeng.
●Li-algorithms tsa software tse tsoetseng pele li ntlafatsa ho nepahala ha liteko tsa li-sensor.
●Tharollo ea tlhophiso ea chassis e kopantsoeng, basebelisi ba ka kopanya lisebelisoa le lisebelisoa tse amanang habonolo.Pakete e akaretsang e etsoa, e etsang hore mosebelisi a be le boiphihlelo bo khutsitseng.
●Teko ea ho qala, ha ho hlokahale hore e sisinyehe.
●Phetoho ea mocheso le tokiso ea data ea khatello.
●Theknoloji ea khomphutha e makatsang.
●Matla a matla a matla a betri ea lithium, hlokomela phepelo ea matla a mabeli a AC le DC.Ha ho na motlakase oa AC o hlokahalang sebakeng sa marang-rang.Phepelo ea matla a betri ea lithium e ntse e tsoela pele ho sebetsa lihora tse fetang 8 ntle le tlhoko ea matla a kantle.
●Moralo oa potoloho ea litšitiso tsa anti-electromagnetic ho netefatsa ts'epahalo ea sehlahisoa.
●Mohopolo o nang le bokhoni bo boholo, o ka hlokomelang lihlopha tse 1000 tsa mesebetsi ea polokelo ea data.
●Ho nepahala ha tekanyo ea bohloeki ke 0.5% ka botlalo.E ka sebelisoa ho lekanya khase e phahameng ea SF6 le 70% ea khase ea SF6.
●Sebaka se setle ka ho fetisisa sa phallo ea teko se bontša hore mosebedisi a ka fetola phallo ea khase ka mokhoa o hlakileng le ka potlako.Fokotsa nako ea teko.
●Mohaho o kenang moeeng o entsoe ka motsoako o monyenyane oa ho itšireletsa, 'me tsela ea moea e lokelang ho lekoa e ke ke ea tsoa ha tsela ea moea e khaotsoe.
●E ka holisa puisano ea USB, puisano ea serial, module ea puisano e se nang mohala, le ho hlokomela mesebetsi ea puisano le khatiso ea komporo e holimo.(ka boikhethelo)
●Ts'ebetso ea ho lokisa tsela ea khase e ka sebelisoa ho hloekisa lipeipi tsa tlhahlobo pele ho mosebetsi oa tlhahlobo ea masimong, e khutsufatsang nako ea teko.(ka boikhethelo)
●Sesebelisoa se na le ts'ebetso ea tlhahlobo ea khase ho khutlisa khase ea tekanyo ea sulphur hexafluoride.Sireletsa tikoloho ea tlhaho.(ka boikhethelo)
Mokhoa oa ho lekanya | Molao-motheo oa Tekanyo ea Infrared (NDIR series sensors) |
Tikoloho ya mosebetsi | -20 ℃ ~ +60 ℃ |
Lekhalo la ho lekanya | 0 ~ 100% SF6 |
Nako ea ho arabela | [90%] 60s |
Ho nepahala | ± 0.5% FS |
Pheta-pheta | ± 0.5% |
Qeto | 0.01% |
Pontšo yuniti | % |
Sekhahla sa phallo ea khase | 400 ~ 600ml / min |
Pontšo ea sekhahla sa phallo | 0 ~ 1000mL ho kenya phallo ea dijithale |
Khatello e bonolo ea khase | ≤1MPa |
Mongobo wa tikoloho | 90% RH |
Tšusumetso ea boleng ba tekanyo | Ha ho phello ea khatello le phallo |
Phepelo ea motlakase | AC 220V±10%, 50Hz / DC Battery ka hare e ka sebetsa bonyane lihora tse 8 |
Boemo | 395*295*155mm |
Boima ba 'mele | hoo e ka bang 2kg. |