GDPQ-300E Mohlahlobi oa Boleng ba Matla
GDPQ-300E Power Quality Analyzer ke sesebelisoa se nkehang habonolo sa liteko le ho sekaseka boleng ba ts'ebetso ea sistimi ea matla.E hlokomela le ho bokella lintlha ka nako e telele, hape e fana ka tlhahlobo ea harmonic le tlhahlobo ea boleng ba matla.Ho sa le joalo, e hlomella ka software ea tlhahlobo ea data, eo data ea tekanyo e ka romelloang ho PC.
●ARM le DSP, memori ea 16M byte.
●Thepa skrineng, e bonolo le e bonolo haholoanyane.
●Ho lekanya le ho boloka data, ho ka romelloa ho PC.
●Sebopeho sa module, moralo o utloahalang le ts'ebetso e ka tšeptjoang.
●Ho bonolo ebile ho bonolo ho ntlafatsa software.
●Tlhahlobo e qaqileng ea tekanyo ea data ka software ea tlhahlobo ea data ea boleng ba matla ho PC.
Mesebetsi ea ho lemoha metha
No | Lintho | Tlhaloso |
1 | Voltage/Hajoale/Frequency | E ka metha tharo-phase voltage, zero line voltage, three phase current, zero line current, frequency. E ka bonts'a RMS, boleng ba tlhoro, karo-karolelano ea maqhubu / tlhoro, waveform, lichate tsa Trend joalo-joalo. |
2 | Htekanyo ea maqhubu a armonickelello | E ka metha leqhubu la motheo la motlakase le hona joale le2 ~ 50 linako tse ling li-harmonicsleqhubu.Liphetho tsa litekanyo li kenyelletsa katleho ea li-harmonic, litaba tsa harmonic, litaba tsa harmonic, le ho sotha ho felletseng (THD).Histograms le mekhoa lichate, joalo-joalo. |
3 | Tekanyo ea interharmonic | E ka lekanya 0.1 ~ 19.9 linako li-interharmonics tsa motlakase le tsa hona joale.Liphetho tsa litekanyo li kenyelletsa likarolo tsa interharmonic le litekanyetso tse sebetsang tsa subset, tekanyo ea interharmonic content. etc. e ka bonts'a li-histograms, lichate tsa feshene, joalo-joalo. |
4 | Tekanyo ea matla | E ka metha tharo-mohato terata e mene/mohato wa boraro-tharo matla a bonahalang (matla a motlakase), matla a sebetsang (matla a motlakase), matla a sebetsang (matla a motlakase), ntlha ea matla etc., e ka bonts'alichate tsa mekhoa; e ka metha tlhokeho of 1, 5, 10, 15, 30 60 metsotso. |
5 | Mekhahlelo e meraro ea ho se leka-lekane | E ka khonalekanya methati e meraro ea mehala ea terata e mene / mehato e meraro ea matla a motlakase a terata e meraro le karolo ea hona joale ea tatelano e nepahetseng, karolo e mpe ea tatelano, karolo ea tatellano ea zero, tekanyo e mpe ea ho se leka-lekane ha tatellano, tekanyo ea ho se leka-lekane ha tatellano ea zero;phase angle ea motlakase oa mekhahlelo e meraro le ea hona joale,vector, mokhoa lichate. |
6 | Flicker | Motsotso o le 1, lebelo le khuts'oane la metsotso e 10, tekanyo ea nako e telele ea lihora tse 2 |
7 | Ho ruruha ha Voltage / Dip / Khatiso | E lemoha lelikutu ho ruruha ha motlakase, ho fokotseha le ho senyeha diketsahalo. |
8 | Shlohlelletsa hona joale | Ho sibolla le li-log tšubuhlellano diketsahalo tsa jwale |
9 | Matla a Harmonic | E khona ho bona 2-30 linako matla a harmonic, a ka bonts'a histogram, mokhoalichate, joalo-joalo. |
10 | Leqhubu la matla | Clekanya phetoho e potlakileng ea matla (matla a sebetsang, a sebetsang, a bonahalang) ho latela nako e behiloeng (metsotso e 1 ~ 5) |
11 | Li-transients | CHo bona hore motlakase o nka nako e telele ho feta 20 microseconds |
8 | Rekoto ea ho beha leihlo | E ka rekota liparamente tsa boleng ba matla a boemo bo tsitsitseng ka nako e telele, ho kenyeletsoa voltage / hajoale / frequency, harmonics, matla, ho se leka-lekane ha mekhahlelo e meraro, ho feto-fetoha ha maemo / flicker, mme nako ea ho rekota e ka fetoloa ho tloha metsotsoana e 3 ho isa ho metsotso e 30. |
9 | Digital oscilloscope | Sheba mofuta oa maqhubu a motlakase / hona joale |
Lenane le leng le le leng la ho nepahala bakeng sa mesebetsi ea ho lemoha
Ntho | Lekhalo la mefuta | Lekanya ho nepahala | Ela hloko |
Voltage/jwale /frequency | Three phase voltage: 1000V (boleng bo sebetsang) ZEro line voltage: 70V (boleng bo sebetsang) Three phase hajoale: 6000A (boleng bo sebetsang, 1000A sensor ea hajoale bakeng sa boikhethelo) Zero line current : 25A (boleng bo sebetsang) FTlhaloso: 40-70Hz | Palo ea li-volts:0.1%rdg±0.05%fs Hona joale: 0.2%rdg±0.05%fs Frequency/ Ketso ya ho bala: ho bala±0.01Hz | HEre, re sebelisa A phase voltage frequency joalo ka tekanyo ea frequency |
Harmonic wave tekanyo | VHarmonic ea khale: THD +Leqhubu la motheo+ 2-50 linako tse ling leqhubu la harmonic. Charmonic ea morao-rao: THD+Leqhubu la motheo+ 2-50 linako tse ling leqhubu la harmonic. | Voltage harmonic wave: Uh≥1% UN±5% Uh; Uh<1% UN±0.05% UN Leqhubu la hona joale la harmonic: Ih≥3% HO±5% Ee; Ih<3% HO±0.15% HO | |
Inter harmonicleqhubulekanya | Voltage harmonic: 0.1 ~ 19.9 linako tse lingInterharonictsokotsane . Charmonic ea morao-rao: 0.1 ~ 19.9 linakoInterharonicleqhubu | Palo ea li-voltsInterharonicwave: Uih≥1% UN,5% Uena; Uih<1% UN,0.05% UN; Hona joaleInterharonicwave: Iih≥3% HO,5% Ee; Iih<3% HO,0.15% HO | |
Petsoe / Matla a motlakase | Amatla a sebetsang: 700kVA Rmatla a sebetsang: 700kVAR Ntho ea matla: 0.00 ~ 1.00 Amatla a sebetsang: 10000kWh Amatla a bonahalang a matla: 10000kVAh Rmatla a sebetsang a matla: 10000kVARh Akarolelano ea matla a matla: 0.00-1.00 | Active: ho bala±0.5% Aparent/ Ketso ya ho bala: ho bala±0.5% Reactive: ho bala±0.5% Power factor/ Ketso ya ho bala: ho bala±0.005 | |
Three phase ho se leka-lekane | Fmatla a tlase: 1000V (boleng bo sebetsang) Fundamental current: 6000A (boleng bo sebetsang) Fmaqhubu a tlase: 40-70Hz Pangle ea hae: 0-360degree Uho leka-lekana: 0.0% -100% | Vboholo: 0.1%rdg±0.05%fs Cea morao-rao: 0.2%rdg±0.05%fs Frequency/ Ketso ya ho bala: ho bala±0.01Hz PHase angle/ Ketso ya ho bala: ho bala±0.3 degree Voltage unbalance/ Ketso ya ho bala: ho bala±0.2% Current unbalance/ Ketso ya ho bala: ho bala±0.2% | Mona, re sebelisa A phase voltage frequency e le kakaretso ea litekanyo tsa frequency |
Voltage Flicker | Metsotso e 1, nako e khuts'oane, ho panya ha nako e telele | Motsotso o 1 o panya-panya:±5.5% Metsotso e 10 e khuts'oane:±5% Lihora tse 2 tsa nako e telele:≤±5% | |
Voltage e ruruha, qoelisa le ho emisa | Lekola le ho rekota ho ruruha ha motlakase oa mokhahlelo o le mong / oa mekhahlelo e mengata, ho putlama ha motlakase le ho tima ha nakoana | Half-wave RMS, nako ea ho qala, nako, phoso ea nako ea ho qetela ± 10ms | Ho fihlela ho lirekoto tsa liketsahalo tse 40 |
Surge Current | Lekola le ho rekota maqhubu a maqhubu a mokhahlelo o le mong/mehato e mengata | Half-wave rms value, nako ea ho qala, nako, phoso ea nako ea ho qetela ± 10ms | Emisa ho metha ha o nka ketsahalo |
Matla a maqhubu a Harmonic | Kakaretso ea linako tsa matla a harmonic: 1 ~ 30th Harmonic kakaretso ea matla a sebetsang:∑P Harmonic total reactive matla:∑Q Positive harmonic ka kakaretso matla a sebetsang: +∑P Matla a sebetsang a negative a harmonic: -∑P Positive harmonic total reactive matla: +∑Q Negative harmonic total reactive matla: -∑Q | Ho bala matla a Harmonic: ± 0.5% | |
Leqhubu la matla | E ka bona bolelele ba metsotso e 1, 3, 5 ea matla a sebetsang, a sebetsang, a bonahalang a le halofo ea maqhubu, mokhoa oa ho rekota oa phetoho ea matla. | Half-wave matla a ho bala: ± 0.5% | |
Nakoana | Li-transients tsa motlakase tse ipapisitseng le boleng bo ikhethileng bo fetang 120% | 1.tbonyane nako ea liketsahalo tse ka lekanngoang ke ho feta 20 microseconds 2.monyetla oa ho hapa ketsahalo 98.7% | Liketsahalo tse 20 li ka bolokoa ka tekanyo e le 'ngoe |
Monitoring record | Rliparamente tsa ecord li kenyelletsa voltage, hajoale, maqhubu, maqhubu a motlakase / maqhubu a hona joale a harmonic (kakaretso ea harmonic + 1-25 linako tsa harmonic), t.ho se leka-lekane ha mekhahlelo e meraro;matla a sebetsang / a sebetsang / a bonahalang, matla a matla;fluctuation/ Boetsuwa | Nako ea ho boloka data: 3s ~ 30min Nako ea nako ke 3s, 'me nako eohle ea ho shebella ke 16h; Nako ea nako ke 30min, mme kakaretso ea nako ea ho beha leihlo ke 960h. | |
Doscilloscope ea igital | Three phase voltage, three phase current, zero line voltage le zero line current wave form form | Max.maqhubu a mohlala: 200kHz Min.maqhubu a mohlala: 100Hz |
●Loop ea ho kenya lets'oao la motlakase:
Ho fihlella ka kotloloho, ho sitisoa ho kenya: 1MΩ, 20pF
Lethathamo la tekanyo: boleng bo sebetsang ba voltage 1000V
Tšebeliso ea matla: tlase ho 0.5VA / mohato
●Loop ea hona joale ea ho kenya:
Phihlello e sa tobang
Lethathamo la litekanyo: Boleng ba hajoale bo sebetsang 1A, 5A, 10A, 100A, 500A, 1000A, 3000A (khetha kutlo e tsamaisanang ea hajoale)
Tšebeliso ea matla: Ka tlase ho 0.5VA / mohato
●Lekanya lebelo la maqhubu a lets'oao: 40Hz-70Hz
●Pontšo ea skrine: 5.7 inch 640 * 480 mmala LCD le skrine thetsana
●Polokelo ea memori: 128M byte FLASH
●Boema-kepe bo ka ntle: USB ( plug ho USB disk)
●Phepelo ea motlakase e sebetsang: Betri ea Li-chargeable, 5-6hours nako ea ho sebetsa bakeng sa tefo e felletseng
●Phepelo ea matla: AC100-240V/DC 16.8V-1A adaptara ea matla / tjhaja
Mohlahlobi | 1 sete |
5A Letlapa la hona joale | 3 likotoana |
Mohala oa tlhahlobo ea motlakase | 1 sengoathoana |
Adapter ea matla | 1 sengoathoana |
Fetola terata | 1 sengoathoana |
QC e feta | 1 khopi |
Buka ea Mosebelisi | 1 khopi |
Tlaleho ea tlhahlobo ea fektheri | 1 khopi |
Lenane la ho paka | 1 khopi |