GDOT-100D 100kV Insulation Oil Tester
Sistimi ea matla, sistimi ea terene le likhoebo tse kholo tsa indasteri ea petrochemical kaofela li na le lisebelisoa tse ngata tsa motlakase, ho kenella ka hare ho eona hangata ke mofuta o tlatsitsoeng ka oli.
Teko ea matla a dielectric bakeng sa oli e sireletsang ke teko e tloaelehileng e tla lekanngoa.
E le ho finyella litlhoko tsa 'maraka.Khamphani ea rona e iketselitse le ho hlahisa GDOT letoto la dielectric matla tester bakeng sa oli ea insulation ho latela maemo a naha a GB/T5072002, standard standard ea indasteri DL429.991 le standard ea morao-rao ea indasteri ea matla a motlakase DL/T846.7- 2004.
Sesebelisoa se sebelisa microcomputer e le 'ngoe e le motheo, ho fihlela tlhahlobo e felletseng ea othomathike le tekanyo e nepahetseng e phahameng, e ntlafatsa haholo ts'ebetso ea mosebetsi le ho fokotsa matla a basebetsi haholo.
●Ka microprocessor, linoelo tse tharo ho e le 'ngoe, ka bo eona e tlatsa matlafatso, ho ts'oara, ho sisinyeha, ho lokolla, ho bala le ho hatisa.
●E nolofalletsa ho tsamaisa oli e potolohang ho mamella teko ea voltage ho tloha 0-100KV.
●Pontšo e kholo ea LCD skrineng.
●Ho bonolo ho sebetsa, ka bohona ho tlatsa lisampole tsa oli tse 1-3 ho latela tlhahlobo ea voltage ho latela litlhophiso.Sampole e 'ngoe le e 'ngoe ea oli e tla bolokoa ka bo eona bakeng sa boleng bo bong le bo bong ba ho senyeha ha motlakase le nomoro ea potoloho.Kamora hore tlhahlobo e phethoe, mochine oa khatiso o futhumatsang o ka hatisa boleng ba motlakase oa ho senyeha le boleng ba karolelano ea sampole ka 'ngoe ea oli.
●Letoto lena le na le ts'ebetso e matla, eseng feela e ka sebelisoang lilaboratori, empa hape e sebelisoa masimong a ka ntle.Sesebelisoa se boetse se na le bokhoni bo matla ba ho thibela ho kena-kenana le ho kena-kenana le ho sebetsa ka mokhoa o tloaelehileng tikolohong e matla ea tšimo ea motlakase.E loketse haholo ho sebelisoa mafapheng a nang le lisampole tse ngata tsa oli le nako ea teko e thata.
●Ka ts'ebetso ea ts'ireletso ea over-voltage, over-current, zero return return, e ka netefatsa polokeho ea basebelisi le sesebelisoa ts'ebelisong e tloaelehileng.
●Ho eketsa lebelo ho ka behoa ho latela maemo a fapaneng a teko.
Matla a tsoang | 0-100kV |
Sekhahla sa ho sotha matla | <3% |
Voltage e eketsa lebelo | 2.0,2.5,3.0,3.5kV/s (e ka feto-fetoha) |
Phoso ea tekanyo ea motlakase | ±3% |
Bokhoni | 1.5kVA |
Ho kenya matla | AC220V± 10%, 50Hz±1Hz |
Matla | <200W |
Mocheso o sebetsang | 0 ℃-+40 ℃ |
Bophahamo ba senoelo sa oli | 200mL (400mL ha u khetha) |
Sekheo sa elektrode | 2.5 limilimithara |
Mongobo | <80%RH |
Boemo | 470*430*480mm |
Boima ba 'mele | 49 lik'hilograma |