GDCY-20B 20kV Impulse Voltage Tester (Mofuta oa Motheo)
GDCY-20B Programmable Automatic Impulse Voltage Tester e thehiloe haholo-holo ho TB/T 2653, GB/T 17627, GB/T 16927, GB14048, GB7251, GB/T 16935, IEC 61730, GB4706, JB8 7 tse ling tse tloaelehileng le JB3048 ditlhoko.E sebelisoa haholo bakeng sa ts'ebetso ea ts'ireletso (dielectric performance) ho lemoha lisebelisoa tsa motlakase tse nang le matla a tlase, li-switches tse phahameng le tse tlase tsa motlakase, matla a letsatsi, limithara tsa motlakase, li-relay, li sireletsang ho lutla, joalo-joalo. Tlhahiso e ka laoloa ke komporo le tlhahlobo. tlaleho e ka hatisoa le ho hlahisoa.
●Mokhoa oa matsoho / o ikemetseng / o hlophisitsoeng: Mokhoa oa letsoho o fetola motlakase oa motlakase ka letsoho ka ho lokisa knob;Mokhoa oa othomathike o ikamahanya le motlakase oa motlakase ka bohona ka sistimi;Mokhoa o ka sebelisoang o sebelisa komporo ho laola motlakase oa motlakase ka bo eona.
●Automatic mode le programmable mode li na le automatic voltage constant system, e ka laolang impulse output voltage ka nepo mme ha e amehe ke nako ea nako.
●Ts'ebetso ea taolo e hlophisitsoeng e fana ka sebopeho sa puisano sa 485 le protocol ea taolo ea lenaneo.Sistimi ea tlhahlobo e ka hlophisoang e ka hlophisoa ho latela tlhoko.Impulse voltage le li-parameter tse fapaneng (programmable trigger) li ka laoloa ke komporo kapa marang-rang a hlophisitsoeng.
●Ka software ea ho laola lenaneo la khomphutha, tlhahlobo ea motsoako oa batch e ka phethahala, joalo ka makhetlo a 2KV3, makhetlo a 4KV3, makhetlo a 6KV3, linako tse -2KV3, linako tse -4KV3, linako tse -6KV3, joalo-joalo Ho ka phethahala lihlopha tse 50 tsa tlhahlobo ea motsoako, 'me liphetho tsa liteko tse kang linako tsa ho senyeha le motlakase oa ho senyeha li ka khutlisetsoa khomphuteng.Khomphuta e ka hlahisa liphetho tsa maikutlo ka mokhoa o hlakileng ho etsa hore kahlolo e be bonolo haholoanyane.
●Tlaleho ea teko e ka hatisoa le ho hlahisoa ke k'homphieutha, 'me data ea teko e kang tlhōrō ea boleng, palo ea tšusumetso le nako ea nako e ka bontšoa.
●Ts'ebetso ea ho ahlola ka boiketsetso ea liphetho tsa liteko e ka ahlola ka bo eona hore na tlhahlobo e tšoaneleha kapa che ho latela boholo le attenuation degree ea impulse current e hlahisoang nakong ea tlhahlobo.
●E fana ka sebopeho sa "impulse divider" bakeng sa oscilloscope ho lekola sebopeho sa maqhubu a motlakase le ho lekola motlakase o tsoang.
●128 * 64 LCD ponts'o, e bonts'ang motlakase oa DC, motlakase oa motlakase, nako ea nakoana, le palo ea tšusumetso.
●Likonopo tsa ho ama, taolo ea PC, phanele ea Senyesemane le menu ea lenaneo lia fumaneha.
●Polarity e ntle le e mpe e entsoe ke sistimi e habeli ea mohloli oa motlakase o phahameng le mohloli o mobe oa motlakase o phahameng.Sehlahisoa se tsitsitse haholoanyane, motlakase o phahame 'me katleho e phahame.
●Ts'ebetso ea mantlha ea tekanyo e felletseng, ho nepahala ho felletseng ho molemo.
●E hahelletsoeng ka har'a li-parameter tse ngata tse tloaelehileng tsa calibration, phoso e ka lokisoa neng kapa neng.
●DC le impulse dual output.
●Phello ea tlhōrō ea tlhōrō ea motlakase: 20kV (4kV-12kV), ho nepahala: + 3%;
Tlhophiso e tobileng ea mefuta e mengata ea motlakase ka mokhoa o itekanetseng le mokhoa o ka khonehang: 4kV-20kV;
Mohato oa Voltage: 1V;
●Impulse voltage waveform: wave front time 1.2μs ± 30%;
leqhubu halofo-tlhōrō nako 50μs±20%;
●Kahlolo ea ho senya: hona joale ho lutla: 30mA-1200mA e ka behoa;
attenuation ea motlakase: 0-99% e ka behoa;
●Nako ea nakoana: 1-9999S;
●Palo ea tšusumetso: 1-9999 / e sa feleng e tsoelang pele;
●Polarity: Positive / Negative / Positive le Negative beha ka tsela e fapaneng;
●Boima: 450mm * 380mm * 240mm;
●Boima ba 'mele: hoo e ka bang 12 kg;
●Ts'ehetso ea Tsamaiso ea Katoloso ea Boikhethelo: WinXP Win7.
Impulse Voltage Tester: 1 sengoathoana
Lithapo tsa teko ea matla a phahameng le a tlaase: 1 set
Cable ea puisano ea 485-USB converter: 1 sengoathoana
DB9 Serial koung katoloso ya thapo: 1 sengoathoana
Software ea mantlha ea sistimi ea taolo: 1 sete