GD-2134E ke mokhoa o phahameng oa ho lemoha lipeipi tsa tšepe tse ka tlas'a lefatše tse entsoeng ka li-transmitters le li amohelang.E ka sebelisoa bakeng sa ho lemoha tsela, tlhahlobo ea lipeipi le tekanyo ea botebo ba lipeipi tsa tšepe le lithapo tse ka tlas'a lefatše.E ka etsa boitsebahatso bo ikhethang ka lisebelisoa tse fapaneng tse khethiloeng, hammoho le ts'enyo ea ho kenya liphaephe le ho batla mefuta e meng ea liphoso tsa cable.
●Pontšo ea Compass: Ka nepo e bonts'a sebaka sa lipeipi le litsela tse ka ho le letšehali le tse nepahetseng.
●Ho latela lintlha tsa 'nete le tsa bohata: tekanyo ea tataiso ea hajoale, ho latela likeletso tse nepahetseng tsa liphoso, ho tlosa tšitiso ea mohala (maqhubu a mang).
●Litekanyo tse tebileng le tsa hona joale, li ka bonts'a lekhalo la nalane la matla a lets'oao.
●Ts'ebetso ea sampole e nepahetseng ka botlalo ea dijithale: e tsitsitse ebile e ka tšeptjoa, kutlo e phahameng haholo, e tšesaane ea ho amohela li-passband, bokhoni bo matla ba ho thibela tšitiso, e ka hatella ka botlalo maqhubu a matla le tšitiso ea harmonic ea likhoele tse tsamaeang le liphaephe tse haufi.
●Ho lemoha ha cable e mathang: li-clamp tsa phetisetso tse sebetsang hantle haholo, lets'oao le phahameng la coupling ho thapo e sebetsang.
●Boitsebiso ba cable / pipe: Li-clamp tse feto-fetohang (ho ikhethela) li bonolo ho li sebelisa 'me li fana ka liphetho tsa boitsebiso ka ho hlaka;stethoscopes (ho ikhethela) e ka sebelisoa ha ho se bonolo ho sebelisa li-clamp.
●Ho fumana phoso e tlase: HV booster (ka boikhethelo) e nyolla matla a phahameng a motlakase ho fihla ho 1000V, e sebelisa foreimi ea A (ho ikhethela) ho fumana libaka tsa ho robeha ha liphaephe, ha ho na tlhoko ea ho fetola zero.Motsu o bonts'a tataiso ea ntlha ea phoso.
●Maqhubu a mangata a ho lemoha: ho lemoha ka mafolofolo le ho lemoha feela.
●Mefuta e fapa-fapaneng ea tlhahiso ea pontšo ea transmitter: tlhahiso ea khokahanyo e tobileng, tlhahiso ea ho kopanya li-clamp, tlhahiso ea mahlaseli.
●Phallo e phahameng ea matla a transmitter, tlhahiso e ngata e ka feto-fetoha, ho tsamaisana le ts'ireletso ea othomathike.
●Sehlopha sa betri sa lithium ion se hahiloeng ka har'a matla a maholo, se tla tima ka boiketsetso kapa se sa sebetse nako e telele,
●Mokotla o matsutla, o bobebe ebile oa nkeha.
Phetiso
●Mekhoa ea tlhahiso: tlhahiso e tobileng ea khokahanyo, tlhahiso ea mahlaseli, tlhahiso ea ho kopanya li-clamp (ho ikhethela), phoso ea ho fumana HV booster (ho ikhethela).
●Khafetsa ea tlhahiso: 640Hz (maqhubu a motsoako), 1280Hz (maqhubu a motsoako), 10kHz, 33kHz, 82kHz, 197kHz.
●Matla a ho tsoa: Max.10W, li-gear tse 10 tse ka feto-fetohang, li-impedance tsa othomathike tse tsamaellanang.
●Khokahano e tobileng ea motlakase: boholo ba 150Vpp.
●Tšireletso e feteletseng le e khutšoanyane ea potoloho.
●Sehokelo sa mochini oa motho: ponts'o ea LCD ea 320 x240 dot matrix.
●Betri e hahiloeng ka hare: 4 karolo ea 18650 lithium ion betri, lebitso la 7.4V, 6.8Ah.
Moamoheli
●Mokhoa oa ho kenya: Khoeli e hahelletsoeng ka hare, li-CTs tse flexible clamp-on(boikhethelo), Stethoscope(ka boikhethelo), Sesebelisoa sa mofuta oa ho bona phoso(ho ikhethela).
●Khafetsa ea ho fumana:
Nako ea ho lemoha e sebetsang bakeng sa Lipeipi: 640Hz, 1280Hz, 10kHz, 33kHz, 82kHz, 197kHz.
Maqhubu a ho lemoha maqhubu a matla: 50Hz/60Hz le 250Hz/300Hz (mosebelisi a ka lokisoa).
Leqhubu la ho lemoha ha RF: maqhubu a bohareng ke 10kHz, 33kHz, 83kHz ka ho latellana.
●Mokhoa oa ho lemoha lipeipi: Mokhoa o pharalletseng oa tlhoro, mokhoa o moqotetsane oa tlhoro, mokhoa oa Phula ea molumo.
●Mokhoa oa ho tsebahatsa thapo: boitsebahatso bo feto-fetohang ba clamp-on CTs(ka boikhethelo) le tekanyo ea hajoale, boitsebahatso ba stethoscope(ka boikhethelo).
●Pontšo ea 320 * 240 LCD, e bonts'a amplitude ea pontšo, tataiso e ka letsohong le letšehali / le letona, pontšo e nepahetseng / ea bohata, lekhalo la histori la matla a pontšo, botebo, hona joale le sephetho.
●Battery e hahiloeng, karolo ea 2 18650 lithium ion betri, e lekantsoeng 7.4V, 3.4Ah.
Ba bang
●Boima: Transmitter 280 * 220 * 90mm.Moamoheli 680*270*120mm.
●Boima ba 'mele: Transmitter 2.2kg.Moamoheli 3.5kg.
●Charger: AC100-240V input, 50/60Hz, tlhahiso DC 8.4V, 2A/3A.
●Boemo ba ho sebetsa: Mocheso -10-40 ℃, Mongobo 5-90% RH, bophahamo <4500m.
Phetiso
Transmitter ka kakaretso | Keybhoto ea ho fetisa |
1. Pontšo ea LCD 2. Keyboard 3. Sokete e hlahisoang 4. Sokete ea ho tjhaja | 5. Matla ON/OFF 6. Senotlolo sa ho ntša hape 7/8.Ho fokotsa matla a ho ntša/ho eketsa senotlolo 8/9.Ho fokotsa makhetlo a mangata/ho eketsa senotlolo |
Moamoheli
| |
Moamoheli ka kakaretso | Keybhoto ya moamohedi |
1. Pontšo ea LCD 2. Keyboard 3. Itloaetse ho itloaetsangkotola 4. Sokete ea ho tjhaja 5. Sesebelisoa sa ho kenya lisebelisoa | 6. Switch/Ho homola senotlolo 7. Senotlolo sa mode 8. Senotlolo sa ho fokotsa maqhubu 9. Senotlolo sa ho eketsa khafetsa 10. Senotlolo sa calibration 11. Senotlolo sa ho lekanya |
Lisebelisoa tse tloaelehileng
Che. | Lebitso | Litšoantšo le litaelo | Qty. |
1 | Cable ea khokahanyo ea transmitter | 1 | |
2 | Ho cheka fatše | 2 | |
3 | Mohala oa katoloso ea mobu | 1 | |
4 | Charger | Tstandard, transmitterlemoamoheli o tlameha ho lefisoa ka thoko | 2 |
Lisebelisoa tseo u ka li khethang (Hlalosa ha u odara, maemo a sa hlalosoang ha a khethoa)
Che. | Lebitso | Litšoantšo le litaelo | Ela hloko |
1 | Cthapo ea onnecting bakeng sa moamohelilisebelisoa. | Plaka e putsoa ea 6-core | |
2 | Connecting cable bakeng salisebelisoa tsa transmitter. | Plaka e khubelu ea 5-core | |
3 | Clamp-on CT bakeng sa transmitter | ||
4 | Flexible CT bakeng sa moamoheli | ||
5 | Aforeimi | ||
6 | Matlafatso ea HV ea ho lemoha liphoso | ||
7 | Stethoscope e nyane | ||
8 | Stethoscope ea kutu e telele | ||
9 | Molamu oa ho lemoha bakeng sa lstethoscope ea kutu |