GDPD-306M Portable Ultrasonic Partial Discharge Detector
GDPD-306M e sebelisoa haholo tlhahlobong e sa lekanyetsoang ea lisebelisoa tsa motlakase.Ho kenyeletsoa li-switchgear tse phahameng tsa motlakase, li-ring mains, li-voltage/transformer tsa hajoale, transformer (e kenyelelitse mofuta o omileng oa transformer), GIS, mehala e holimo, likhoele, le lisebelisoa tse ling tsa tlhahlobo ea boemo ba lisebelisoa.
Matšoao a latelang a sebelisoa ho lekanya tekanyo ea ho tsoa ha lisebelisoa tsa motlakase:
Ho lemoha ha karolo e itseng ea matla a ho ntša matla: Ka ho lekanya letšoao la ho tsoa ka potoloho ea matla a maqhubu a matla, matla a ho ntša karolo e itseng a khetholloa ho ea ka boleng bo phahameng (dB) ka tatellano ea pulse ea discharge.
Ho lemoha ka mokhoa o sa fellang oa ho ntša metsi: Sesebelisoa se lekanya letšoao la ho tsoa ka har'a potoloho ea matla a matla, se ntša maqhubu a ho ntša metsi 'me se khetholla makhetlo a mangata a ho tsoa ha karolo ho latela palo ea likhahla tse tsoang.
●Ka li-sensor tse fapaneng ho fihlela tlhahlobo e sa lekanyetsoang ea lisebelisoa tsohle tsa motlakase.
●Fana ka mekhoa e mengata ea ho lahla e kang nako-domain waveform, PRPD, PRPS, joalo-joalo, ho hlokomela tlhahlobo ea mefuta e fapaneng ea ho tsoa.
●Sehokelo sa mochini oa motho se sebetsang hantle se thusa taolo ea data ea lisebelisoa tse fapaneng, ho kenyeletsoa ho lateloa ha mekhoa ea phetoho ea data ea nalane, tlhahlobo ea data e otlolohileng le e otlolohileng, le ho lemoha tlhahlobo e felletseng ea 360 ° ea sesebelisoa se lekiloeng.
●Sensor e hahelletsoeng ka har'a ultrasonic le voltage ea lefatše ea nakoana (eo ka morao e bitsoang TEV) sensor, e ka hokahanngoa le li-sensor tse khethehileng tsa kantle tsa li-transformer, GIS, mela e holimo le likhoele.
●E sebelisa mokhoa oa ho lemoha o sa tsitsang, ha ho na tlhoko ea ho tima nakong ea tlhahlobo, ha ho na tlhoko ea ho hlophisa mohloli o eketsehileng oa motlakase o phahameng, ho bonolo ho o sebelisa ho feta sebui sa ho ntša karolo ea pulsed partial discharge.
●Lebelo la bandwidth ea teko ke 30kHz ~ 2.0GHz, e loketseng melao-motheo ea ho lemoha ea lihlopha tse fapaneng tsa maqhubu.
Tekanyo ea TEV | Tekanyo ea UHF | ||
Tekanyomefuta-futa | 0-60dBmV | Sehlopha sa maqhubu a ho lemoha | 300 ~1500MHz |
Qeto | 1dB | Lekhalo la litekanyo | -75-0dBmV |
Ho nepahala | ±1dB | Ho nepahala | <1dBmV |
Max. pulse ka potoloho | 1400 | Sensor frequency band | 300-2000MHz |
Leqhubu la tekanyo ea tekanyo | 1~ 100MHz | ||
AA tekanyo | Tekanyo ea AE | ||
Lekhalo la litekanyo | -6dBμV~68dBμV | Lekhalo la litekanyo | -6dBμV~68dBμV |
Qeto | 1dB | Qeto | 1dB |
Ho nepahala | ±1dB | Ho nepahala | ±1dB |
Sensor center frequency | 40kHz | Sebaka sa maqhubu | 40-200kHz |
Tekanyo ea HFCT | |||
Sensor phetisetso impedance | 5mV/mA | ||
Khafetsa ea ho lemoha | 1 ~ 30MHz | ||
Kutloisiso | ≤50pC | ||
Lisebelisoa | |||
Khetla | ABS | ||
Pontšo | 4.0inch RGB LCD skrine | ||
Cmolebeli | ARM | ||
Sehokedi | Sehokelo sa USB (kou ea tjhaja), WIFI e se nang mohala 3.5mm headphone jack stereo, benchmark ea khokahano e se nang mohala Kenyelletso ea sensor ea kantle ea ultrasonic | ||
Li-headphone | 8 ohm bonyane | ||
Karete ea SD | Standard 16G | ||
Betri e hahiloeng | 3.7V/1Ah, betri ea lithium | ||
Nako ea ho sebetsa | About8lihora | ||
Charger | AC 90-264V kapa DC 5V | ||
Lithempereichara tse sebetsang | -20~+50℃ | ||
Mongobo | 20 ~ 85% mongobo o lekanyelitsoeng | ||
Boemo, boima | 210*100*35(mm), 0.4kg (yuniti e kholo) |
Sehlopha se seholo | 1 | Stloaelehileng |
EXternal Ikopanye le ultrasonic sensor | 1 | Fkapa khetho, e sebelisetsoang li-transformer, GIS, motors |
USensor ea HF | 1 | Fkapa khetho, e sebelisetsoang GIS |
HFCT | 1 | Fkapa khetho, e sebelisetsoang thapo ea motlakase |
Test cable | 1 | Stloaelehileng |
Charger | 1 | Stloaelehileng |
Mohala oa USB | 1 | Fkapa ho tjhaja le puisano ka PC |
Utataiso ea ser | 1 | |
Ftlaleho ea teko ea actor | 1 |