Tekong ea 'nete le tlhahlobo ea boleng ba matla a marang-rang a matla, ho hlokahala mohlahlobi oa boleng ba matla.Sesebelisoa sena se sebelisoa haholo ho lekanya boleng ba matla 'me se tumme haholo har'a basebetsi ba matla a motlakase.Sehloohong sena, HV Hipot e tla fana ka kenyelletso e khutšoane ea sesebelisoa sena
HV Hipot GDPQ-300A Mohlahlobi oa Boleng ba Matla
Boleng ba matla bo bolela boleng ba matla a AC a fuoang basebelisi ka marang-rang a sechaba.Ka kakaretso, e bua ka boleng ba matla a lithapo tsa marang-rang.Mathata a boleng ba matla a bakoa haholo-holo ke lehlakore la thepa ea motlakase.Mohlala, tšusumetso ea mojaro o sebetsang e tla etsa hore motlakase oa grid o fetohe ka matla le ho fokotsa boleng ba phepelo ea motlakase.
Ka nts'etsopele ea theknoloji ea elektronike ea matla, ha e tlise feela likarolo tse ntle tsa ho boloka matla le phetolo ea matla ho indasteri ea morao-rao, empa e boetse e tlisa mathata a macha le a tebileng ho boleng ba matla ka lebaka la ts'ebeliso e pharaletseng ea lisebelisoa tsa motlakase tsa motlakase likarolong tsohle tsa bophelo.Tšenyo e fetohile mohloli o ka sehloohong oa tšilafalo ea harmonic ea marang-rang a matla.Palo ea li-rectifier, li-frequency converter, libono tsa motlakase tsa arc, literene tse kentsoeng motlakase le lisebelisoa tse fapaneng tsa motlakase le tsa elektroniki marang-rang a phepelo bakeng sa bareki ka bomong tsamaisong ea grid ea eketseha.ama kapa a silafatsa marangrang a matla.Baka ho se tsitse ha motlakase, overvoltage, tlhahiso ea harmonic, joalo-joalo Harmonics e fokotsa katleho ea tlhahiso ea matla, phetisetso le tšebeliso, e etsa hore lisebelisoa tsa motlakase li chese haholo, li hlahise ho sisinyeha le lerata, ho koala lilemo, ho khutsufatsa bophelo ba tšebeletso, esita le ho hlōleha kapa ho chesa.Harmonics e ka boela ea etsa hore resonance ea lehae e tšoanang kapa letoto la li-resonance tsa sistimi ea matla, e holisang litaba tsa harmonic mme e etse hore lisebelisoa tse joalo ka li-capacitor li che.
Litšobotsi tsa ho se lekane, ho ts'oha le ho se leka-lekane ha tšebeliso ea matla ea meroalo ena e baka tšilafalo e kholo boleng ba phepelo ea motlakase.Ka hona, ho felisoa ha li-harmonics tse phahameng tsamaisong ea phepelo ea matla le kabo ea matla ho na le moelelo o motle haholo bakeng sa ho ntlafatsa boleng ba matla le ho netefatsa ts'ebetso e bolokehileng, e tsitsitseng le ea moruo ea sistimi ea matla.Ka lehlakoreng le leng, lisebelisoa tsa motlakase tsa basebelisi ba sejoale-joale ba indasteri, khoebo le bolulo li ela hloko boleng ba motlakase mme li beha litlhoko tse phahameng tsa boleng ba phepelo ea motlakase.Hajoale, li-harmonics, tšitiso ea motlakase le phokotso ea matla li thathamisitsoe e le likotsi tse tharo tse kholo tsa sechaba tsa sistimi ea matla.
Ha boleng ba matla a marangrang a motlakase bo ferekanngoa kapa bo silafatsoa ’me bo hloleha ho finyella litekanyetso tse amehang tsa ntlafatso ea naha, hoa hlokahala ho ntlafatsa tsamaiso ea boleng ba matla a thekenoloji ea marang-rang a matla ka mokhoa o lebisitsoeng.E le hore u utloisise maemo a sebele a ho sebetsa a boleng ba matla a marang-rang a matla, ho hlokahala hore ho be le lisebelisoa tse lumellanang le ho hlahloba lintlha tsa taolo le tlhahlobo.Ho ea ka maemo a sebele a bophelo naheng ea heso, k'hamphani ea rona e ka hlahisa le ho nts'etsapele lisebelisoa tsa tlhahlobo ea boleng ba matla ka nako e loketseng bakeng sa maemo a rona a naha.Lintlha tse latelang ke tlhaloso e qaqileng ea ts'ebetso e khethehileng, litekanyetso, le tšebeliso ea mokhoa ona oa mohlahlobi oa boleng ba matla.
Analyzer ea boleng ba matla ke sesebelisoa sa profeshenale se sebelisoang ke basebetsi ba matla a motlakase ho sekaseka le ho lekola boleng ba matla mosebetsing oa nnete.E tumme haholo har'a basebetsi ba matla a motlakase, kahoo bohle ba hloka ho e tseba hantle.
Nako ea poso: Jun-01-2022