GDBT-1000kVA Transformer Test Benche

Ntho ea Tlhahlobo:
22.9kV Li-transformer tsa Mokhahlelo o le Mong le li-transformer tse khethehileng,matla a motlakase le a hona joale: AC 0-650V/78A, AC 0-1200V/29A, AC 0-2400V/14.6A
Tšitiso ea transformer e lekiloeng e ka har'a 7%, lehlakore la HV ke 23kV, 11kV, 6kV.Lehlakore la LV ke 0.05kV-2.4kV.
Benche ena ea liteko e ka etsa liteko tse latelang:
1. Teko ea ho se be le moroalo ho kenyelletsa tahlehelo ea ho se be le moroalo, peresente ea ho se be le moroalo hona joale ho rated ea hajoale.
2. Teko ea mojaro ho kenyelletsa tahlehelo ea moroalo, peresente ea voltage ea impedance, phetoho ea mocheso o itekanetseng le teko ea tahlehelo ea mojaro tlas'a 30% kapa ka holimo ho nako e tletseng.
3. Teko ea motlakase e kentsoeng.
●Lintlha tsa tlhahlobo ea rekoto ka letsoho ebe u li boloka polokelong ea litaba.
●Lintlha tsa tlhahlobo ea No-load li ka lokisoa ka sebopeho sa waveform le voltage e lekantsoeng ka bo eona.
●Lintlha tsa tlhahlobo ea Load li ka lokisoa ka mocheso (75 ℃, 100 ℃, 120 ℃, 145 ℃) le ho lekantsoe hajoale.
●Tekong ea No-load, voltage ea lehlakoreng la LV e ka beoa leihlo.
●Tekong ea Load, HV side current e ka behoa leihlo.
●Mesebetsi eohle ea liteko le ts'ebetso ea liteko li ka khethoa le ho laoloa ke likonopo tsa phanele e ka pele.
●Liphetho tsohle tsa liteko li lokisoa ho latela tlhoko ea GB1094, IEC60076 kapa ANSI C57.
●Mokhoa oa ho etsa liteko o ka etsoa ka software ea PC.
●Lintlha tsohle li ka bolokoa le ho hatisoa.
●Ka ts'ireletso ea zero, ts'ireletso ea hona joale le ts'ireletso e feteletseng ea motlakase.
●CT/PT mefuta e fapaneng e fetoha ka bo eona.
●Benche ea liteko e tla laola ka botlalo potoloho eohle ea loop le ho lekola tekanyo.
●Sistimi ea alamo ea polokeho.
Transformer Load le No-load Tester (Feela bakeng sa litšupiso, mohlala oa ho qetela ke Fluke Norma 4000)
Matla a matla: 0-1000V
Sebaka sa hona joale: 0.25-20A, ho nepahala 0.2%.
Ho nepahala ha matla 0.3%.
Ntho ea matla 0.050-1.000, ho nepahala 0.3%
Khafetsa 40-70Hz, ho nepahala 0.1%.
Matla P
Ha ho na moroalo hona joale Io, %
No-load tahlehelo Po
Lata thoto Pk
Matla a impedance Uk
Matla Po
Karolelano ea motlakase oa mohala Un
Karolelano ea hajoale ea In.
Litlhaloso tsa HV CT
Matla a matla: 3kV
Lethathamo la ho lekanya: 0.25A-110A
Ho nepahala 0.05%
Karolelano ea ho fetoha ke 100,50,30,20,10,5,2.5/1A
Litlhaloso tsa PT
Mofuta oa motlakase: 0.1kV-3kV(50Hz-400Hz)
Ho nepahala 0.05%
Karolelano ea ho fetoha ke 3,2,1,0.5kV/0.1kV
Phepelo ea Matla a Fetohang
Matla a kenang: Karolo e le 'ngoe ea AC380V, 60Hz
Lebelo la ho lekanya: 0-800V
E lekantsoe matla: 30kVA
Nako ea tlhahiso: 0-37.5A
Khafetsa ea tlhahiso: 180Hz, 240Hz, 400Hz± 2%
Transformer ea Mahareng
Matla: 40kVA
Matla a Kenang: Mokhahlelo o le mong oa 500V
Phallo ea Matla: 0-650V-1200V-2400V
100kVA Single Phase Regulator
Matla a kenang: Mokhahlelo o le mong 380V / 60Hz, motlakase o hlahisoang ke 20-650V.
Max.Mojaro oa hajoale: 154A
Ha se taolo ea ho ikopanya le batho, ho bonolo ho e sebelisa.
Ha motlakase oa ho kenya o lula o le teng, o ka fetola motlakase hantle ka mojaro.E entsoe ka lebelo le lekantsoeng la 60Hz.
Tlhokahalo ea Moqapi
Liteko tsohle tse hlokahalang li hlomelloa bencheng e le 'ngoe, mosebetsi o mong le o mong o ikemetse.Liteko tsohle li iketselitse.
Teko ea Sebopeho sa Transformer(Teko ea Ha ho Mojaro le Mojaro)
E laoloa ke PC 'me e fanoa ka motlakase oa motlakase oa 100kVA, transformer ea mahareng 40kVA.
Re ka etsa mefuta e fapaneng ea litekanyetso ho latela tlhoko ea 'nete.