GDZJ-10S Return-to-turn Surge Tester
GDZJ-10S e sebelisetsoa ho lekola matla a motlakase a fetohang a le mong, karolo ea 3-mohato, enjene e nyane, enjene e khethehileng, enjene ea motlakase, transformer (ho kenyeletsoa le sesebelisoa sa phepelo ea motlakase), relay le lisebelisoa tsa motlakase tse tsoelipanang.
-
GDPD-306M Portable Ultrasonic Partial Discharge Detector
GDPD-306M e sebelisoa haholo tlhahlobong e sa lekanyetsoang ea lisebelisoa tsa motlakase.Ho kenyeletsoa li-switchgear tse phahameng tsa motlakase, li-ring mains, li-voltage/transformer tsa hajoale, transformer (e kenyelelitse mofuta o omileng oa transformer), GIS, mehala e holimo, likhoele, le lisebelisoa tse ling tsa tlhahlobo ea boemo ba lisebelisoa.
-
Mokhoa o sa Lekaneng oa Ts'ebetso ea Ts'ebetso ea Marang-rang ea Lijenereithara
Ka kakaretso, ho tsoa ha karolo e itseng ho etsahala sebakeng seo thepa ea thepa ea dielectric e sa tšoaneng.
-
Sistimi ea Teko ea Impulse Voltage - Lisebelisoa tsa Teko ea Voltage e Phahameng
GDCY series Impulse Voltage Generator e ka hlahisa mefuta e mengata ea motlakase le matla a ho etsisa maqhubu a maqhubu a kang lehalima, leqhubu la lehalima le phunyeletsoeng, ho fetola maikutlo joalo-joalo, ho etsa hore ho khonehe ho etsa liteko tsa mefuta e sa tšoaneng bakeng sa lisebelisoa tse phahameng tsa motlakase, ho sebelisana le ho phahama. sesebelisoa se ka etsa liteko tse matla tsa maqhubu ho insulator (khoele ea insulator).
-
GD6900 Capacitance le Dissipation Factor Tester
GD6900 e lekanya matla le dielectric loss factor (tgδ) ea lisebelisoa tsa motlakase tse phahameng.Ke sebopeho se kopantsoeng, borokho ba tlhahlobo ea tahlehelo ea dielectric e hahelletsoeng, phepelo ea motlakase e feto-fetohang, e matlafatsang transformer le SF6 capacitor e tloaelehileng.
-
GDZRC Series DC Winding Resistance Tester (GDZRC-10A)
GDJRC-10A
GDJRC series DC winding resistance testere etselitsoe ho lekanya khanyetso ea DC ea inductivelisebelisoa, joalo ka li-transformer le li-inductors tsa motlakase.
E na le likarolo tsa tekanyo e potlakileng, boholo bo nyanele ho nepahala ho phahameng hoa tekanyo, e leng lisebelisoa tse loketsengea ho metha transformer matsoelintsoeke le DC khanyetso ealisebelisoa tse kholo tsa ho kenya matla. -
GDYD-2030A 30kVA.200kV Automatic AC/DC Hipot Test Set
GDYD-2030A Automatic AC/DC Hipot Test Set e entsoe ka yuniti ea taolo ea othomathike le transformer ea tlhahlobo ea khase (HV unit) e ntšang motlakase oa AC kapa DC hantle.Ho sa le joalo, e na le mesebetsi e mengata ea ho beha leihlo le ho sireletsa.
-
GDYD-53D 50kV AC DC Dielectric Test Equipment
Teko ea hi-pot ea AC ke mokhoa o sebetsang le o otlolohileng oa ho lekola matla a ho koala lisebelisoa tsa motlakase, lisebelisoa kapa mechini.E hlahloba mefokolo e kotsi e netefatsang lisebelisoa tsa motlakase hore li tsoele pele ho sebetsa.
-
GDZG-300 DC High Voltage Jenereithara
GDZG-300 letoto la DC high voltage tester e ntse e leka DC high voltage bakeng sa zinc oxide lighting arrester, magnetic blowing arrester, lithapo tsa matla, jenereithara, li-transformer, li-switch le lisebelisoa tse ling, tse loketseng lekala la matla a motlakase, lefapha la matla la lifeme, likarolo tsa lipatlisiso tsa saense, terene, indasteri ea lik'hemik'hale, limela tsa motlakase.
-
GDJS-65 Insulation Materials Hipot Test Set
E sebelisetsoa ho hlahloba ts'ebetso ea ho kenya lisebelisoa bakeng sa li-gloves, lieta, mats, likatiba, molamu, Electroscope joalo-joalo E ka hlahloba li-gloves / boots tsa 6pcs ka nako e le 'ngoe, hape le lithupa tsa 5pcs tsa ho pata.
-
GDYD-D AC Dielectric Test Equipment Ka Setsi sa Taolo ea Matsoho
Teko ea AC Hipot ke mokhoa o sebetsang le o otlolohileng oa ho lekola matla a ho koala lisebelisoa tsa motlakase, lisebelisoa kapa mechini.E hlahloba mefokolo e kotsi e netefatsang lisebelisoa tsa motlakase hore li tsoele pele ho sebetsa.
-
GD6800 Capacitance le Dissipation Factor Tester
GD6800 keka ho feletseng 10teko ea kV insulation power factor/dissipation factor (tan∂).ere etselitsoeng tlhahlobo ea boemo ba ho kenya motlakase ka har'a lisebelisoa tse phahameng tsa motlakase tse kang li-transformer, bushings, li-circuit breaker, lithapo, lintho tse thibelang lehalima le mechini e potolohang.