HV-OWS-63 Oscillating Wave Test System (OWTS) bakeng sa PD Diagnostics of Cables
1. Letoto la HV-OWS ke mokhoa o kopantsoeng oa teko ea ho ntša metsi ka mokhoa o sa fellang, o sebelisoang haholo-holo bakeng sa tlhahlobo e sa fellang ea lithapo tsa motlakase tse mahareng.Maqhubu a tlhahlobo ea sistimi ke 50Hz ho makholo a 'maloa a Hz damping AC voltage, matla a damping a AC a hlahisoang ke sistimi nakong ea ts'ebetso ea liteko a ka fihla ho 60kV, mme a kopantsoe le lisebelisoa tse tsoetseng pele tsa sistimi le software ea sistimi bakeng sa tlhahlobo.
●Theknoloji ea morao-rao ea elektroniki ea semiconductor ea matla
●Theknoloji ea morao-rao ea ho laola laser
● Mochine o tsoetseng pele oa lisebelisoa tsa digital le theknoloji ea ho sefa
● Theknoloji e tsoetseng pele ea ho laola marang-rang a se nang mohala.
2. Software ea ho lekanya le ho hlahloba e ka etsa tlhahlobo ea data e hōle tlas'a boemo ba marang-rang.
3. Sebopeho sa ts'ebetso ea Senyesemane se feletseng, se khonang ho hatisa maqhubu a maqhubu a oscillating le li-waveforms tse sa fellang, le ho etsa matheba a nako ea sebele nakong ea khatello ea maikutlo;
4. Bontša ka tsela e iketsang bophara ba maqhubu, amplitude le sampling nako ea oscillating voltage waveform.
5. E ka itlhahloba ka bo eona katoloso ea waveform ea lets'oao le lekiloeng la ho ntša karolo e itseng.
6. Bontša ka mokhoa o itekanetseng boleng ba tlhahlobo ea tahlehelo ea dielectric.
7. Iketsetse 'mapa oa sebaka sa ho hlakoloa ka mokhoa o itekanetseng, 'me u hlahise litlaleho tsa lipalo-palo, 'me u iketsetse 'mapa oa lipalo-palo o sa fellang.
Matla a tsoang | Boholo: ± 60kVtlhoro |
Lebelo la maqhubu a oscillation | 20Hz ~ 850Hz |
Inductance | 1.0H~2.1H (boikhethelo) |
Tlhahlobo ea lintlha | Tlhahlobo ea matsoho, tlhahlobo ea othomathiki (analog le filthara ea dijithale) |
Boholo ba bokhoni bo lokelang ho lekanyetsoa | 0.05~5uF |
Mohala o phahameng oa ho tjhaja motlakase | 10mA |
Karolo ea teko ea ho ntša metsi | 10pC ~ 200nC |
Ho nepahala ha tekanyo | ±0.1pC (sampole 14bits) |
Leqhubu la lebelo | 50-300m / rona |
Ho fumana ho nepahala | ±0.1m |
Phoso ea ho fumana sebaka | ≤1%× bolelele ba cable |
Ho fumanoa ha boemo ba PD | Ho latela IEC60270 |
PD e fumana bandwidth | 100kHZ ~ 50MHZ khetho ea boiketsetso kapa ea matsoho |
boleng ba tahlehelo ea dielectric tan δ | 0.1%~10% |
Matla a phepelo | 180V ~ 250V, AC 50Hz |
Mocheso oa ho sebetsa | -120 ℃~ + 60 ℃ |
Boima ba 'mele | Hoo e ka bang 88kg |
Boholo | Diameter 650mm, bophahamo 980mm |
Sehokedi | WLAN (IEEE802.11g)/100M karete ea Ethernet |
Che. | Lebitso | Qty. |
1 | HV-OWS-63 oscillating wave test system unit unit ea mantlha | 1 sete |
2 | Khomphutha ea li-notebook (e nang le tlhahlobo e kenyellelitsoeng ea ho hlakoloa ha karolo ea oscillating le sistimi ea tlhahlobo ea software) | 1 sete |
3 | Capacitor ea matšeliso ea kantle | 1 sete |
4 | Jenereithara e phahameng ea matla a pulse calibration | 1 sete |
5 | Cable e phahameng ea teko ea motlakase | 1 sete |
6 | Cable e hokelang matla a phahameng (e kopanyang li-capacitor tsa matšeliso) | 1 sete |
7 | Cable ea jenereithara ea pulse (e 'ngoe e khubelu le e' ngoe e ntšo) | 2pcs |
8 | Laola thapo ya ho reka | 1pc |
9 | Cable ea puisano ea marang-rang (e nang le kou ea marang-rang ho ea ho mofuta oa c) | 1pc |
10 | Mohala o fatše | 1pc |
11 | Molamu oa fatše | 1pc |
12 | Motlakase oa motlakase | 1pc |
13 | Lisebelisoa tsa terata pakete | 1pc |
14 | Buka ea ts'ebetso | 1 kopi |
15 | Setifikeiti / Karete ea tiisetso | 1 kopi |
16 | Lenane la ho paka | 1 kopi |