GDZRC-40U (GDJRC-50U) DC Winding Resistance Tester
GDZRC-40U (GDJRC-50U) DC Winding Resistance Tester e etselitsoe ho lekanya khanyetso ea DC ea lisebelisoa tsa inductive, tse kang li-transformer le li-inductors tsa motlakase.E na le likarolo tsa tekanyo e potlakileng, boholo bo nyane, boima bo bobebe, tlhahiso e kholo ea hona joale, ts'ebetso e phethahetseng ea ts'ireletso, bokhoni bo botle ba ho pheta-pheta, bokhoni bo botle ba ho thibela ho kena-kenana, ho nepahala ho phahameng, e leng se etsang hore e be thepa e loketseng ea ho lekanya khanyetso ea DC ea transformer winding le holimo. lisebelisoa tsa ho kenya letsoho.
●E laoloa ke k'homphieutha e le 'ngoe ea lebelo le holimo, e itirisang haholo ebile e bonolo ho e sebetsa.
●E amohela theknoloji e ncha ea phepelo ea motlakase e nang le mehato e mengata ea hajoale le mefuta e mengata ea litekanyo, e loketseng tekanyo ea khanyetso ea DC ea li-transformer tse kholo le tse mahareng.
●Mesebetsi e phethahetseng ea ts'ireletso, e khona ho sireletsa sesebelisoa ho tsoa tšusumetsong ea counter EMF, ka ts'ebetso e tšepahalang haholoanyane.
●Alamo ea ho ntša molumo, pontšo e hlakileng ea ho tsoa, ts'ebetso e fokolang e fosahetseng.
●Lebelo la karabelo e potlakileng, mochini o kenang ka har'a moifo o ka fetoloa ka kotloloho maemong a tekanyo, 'me sesebelisoa se khatholla data ka bo eona.
●Theknoloji e bohlale ea taolo ea matla.Sesebelisoa se lula se sebetsa ka matla a fokolang, a bolokang matla le ho fokotsa mocheso ka katleho.
●65K 'mala oa' nete oa LCD oa bonyane lipikselse tse nyane tse 320X240.
●E na le oache ea khalendara le ts'ebetso ea polokelo ea data ea ho se sebetse, e ka bolokang lisebelisoa tse 1000 tsa data ea liteko mme e ka hlahlojoa nako efe kapa efe.
●E na le RS232 (sehokelo se bolokiloeng) le sebopeho sa USB (bakeng sa polokelo ea USB).
Sephetho sa hajoale | <5mA, 2.5A, 5A, 10A, 20A, 40A | |
Min.qeto | 0.1μΩ | |
Lekhalo la litekanyo | (GDZRC-50U: 40μΩ~400mΩ) 50μΩ~500mΩ 100μΩ~1Ω 500μΩ~2Ω 1mΩ~4Ω 2mΩ~8Ω 10Ω~20KΩ | (GDZRC-50U: 50A) 40A 20A 10A 5A 2.5A <5mA |
Ho nepahala | ±(0.2%+2 linomoro) | |
Mocheso oa ts'ebetso | 0 ~ 40℃ | |
Mongobo | <90%RH (nocondensing) | |
Boholo | 325mm×240mm×275mm (L×W×H) / GDZRC-50U: 400mm×225mm×350mm (L×W×H) | |
Boima ba 'mele | 15kg (ntle le terata ea teko) / GDJRC-50U: 17kg (ntle le terata ea teko) lebokose la mohala oa teko: 3kg |
Mohlahlobi | 1 sete |
Thapo ea matla | 1 sengoathoana |
Teko terata (e khubelu e ntšo e 'ngoe le e 'ngoe e nang le clamp) | 2 likotoana |
Pampiri ea ho hatisa | 2 meqolo |
Fuse | 2 likotoana |
232 serial terata | 1 sengoathoana |
Shunt/ | 1 sengoathoana |
Buka ea Tataiso | 1 sengoathoana |
QC e feta | 1 sengoathoana |
Lenane la ho paka | 1 sengoathoana |
Tlaleho ea tlhahlobo ea fektheri | 1 sengoathoana |