GDYZ-301 Zinc Oxide Surge Arrester Tester
1. 800 * 480 'mala oa LCD touch screen, e nang le mochine oa khatiso oa mocheso o phahameng.
2. Pontšo ea litšoantšo, sebopeho se hlakileng, se bonolo ho sebetsa le ho se sebelisa sebakeng sa marang-rang.
3. Phetiso ea waelese ea sebaka se selelele.PT signal wireless phetiso sebaka se fetang 400m (2000m ka customized).
4. E loketse ho hlahlojoa maemong a fapaneng joalo ka sets'oants'o sa lehalima se nang le motlakase kapa se se nang motlakase, laboratori.
5. Leka likarolo tse tharo tsa hona joale, motlakase oa mekhahlelo e meraro ka nako e le 'ngoe, e sebetsang hantle haholoanyane.
6. Ha ho na motlakase o matla ka hare, motlakase o sa feteng 12V.Li-sensor tsa hajoale le tsa voltage li arohane ka botlalo, li bolokehile ebile li ka tšeptjoa.
7. Ts'ehetsa sampole e fapaneng ea motlakase: 1. Wired;2 wireless;3. Non-voltage;
A. Wire: phetiso ea lets'oao la dijithale ka thapo eo lets'oao le tsoang ho PT metering winding;
B. Wireless: digital signals transmission wireless eo lets'oao le tsoang ho PT metering winding;
C. Non-voltage: ha ho hlokahale ho fumana letšoao ho tloha ho li-terminals tsa PT.Sebelisa lipalo tsa software ho fumana maemo a voltage.
8. Li-betri e hahiloeng ka har'a matla a phahameng, e loketseng sebaka sa ho fana ka matla.
9. E amohela sethala sa hardware se kentsoeng le sistimi e kentsoeng ea ts'ebetso, e ka holisa mesebetsi ea ho bapala ea molumo le video le mesebetsi ea boithabiso ea papali.
10. Sesebelisoa se ka fetoloa le ho tima ka nako leha e le efe, e tsitsitseng ho feta sesebelisoa se nang le k'homphieutha ea indasteri e le sethala sa hardware, 'me ha ho bonolo ho senya le ho oa ha tsamaiso.
11. E na le boema-kepe ba USB ho ts'ehetsa thomello ea data ho tsoa ho disk ea U.
12. Karete ea SD ea 4GB e hahiloeng ka hare, e ka boloka boitsebiso bo bongata ba tlhahlobo, 'me e na le mesebetsi e kang ho laola le ho boloka boitsebiso.
13. Potlako e phahameng ea sampuli ea lebelo, theknoloji e tsoetseng pele ea ho sebetsana le matšoao a digital, ts'ebetso e matla ea ho thibela ho kena-kenana, liphello tse phahameng tsa tekanyo e nepahetseng.
14. Ka lebokose le tiisitsoeng la polasetiki, le sa keneleng metsi, le thibelang ho bola, le nang le boholo bo bonyenyane, boima bo bobebe, bo bonolo ho jara.
1. Phepelo ea Matla
Ts'ehetsa adaptara ea matla a kantle (12V / 2A) le mokhoa oa ho fana ka matla a betri ea kahare;
2. Lebala la ho lekanya
Leakage Current (RMS) 0-10mA (scalable);
Voltage (RMS) 30-100V (scalable).
3. Ho lekanya ho nepahala
Hona joale: kakaretso ea hona joale> 100μA, ± 2% ea ho bala ± 1digit;
Voltage: Reference voltage signal> 30V
Wired: ± 2% ea ho bala ± 1 digit;
Wireless: ± 5% ea ho bala ± 1 digit;
4. Mekhahlelo ea ho lekanya
Boemo ba hona joale ba maqhubu a lutla, maqhubu a mantlha a RMS, boleng ba tlhoro.
Resistive component fundamental wave RMS ea leakage current, 3, 5, 7 times RMS.
Boleng ba tlhōrō ea karolo e hanyetsanang ea ho lutla ha hona joale, ho kenyeletsoa boleng ba tlhoro e nepahetseng Ir+, boleng ba tlhoro e mpe Ir-.
Capacitive current fundamental wave, total voltage, full current phase angle difference.
Motlakase oa RMS.
Tšebeliso ea matla ea sebono.
5. Reference voltage signal sampling mokhoa
Khokahano ea mohala: 20m (e ka atolosoa);
Khokahano e se nang mohala:> 400m (e ka atolosoa);
6. Parameter ea betri
Nako ea ho tjhaja> lihora tse 6
Nako e tsoelang pele ea ho sebetsa> lihora tse 4
Nako ea nakoana ea ho sebetsa> lihora tse 8
7. Boemo:360 * 260 * 140mm (Moamoheli);420 * 330 * 200mm ( Nyeoe ea lisebelisoa);
8. Boima ba 'mele:5kg (Moamoheli);9kg ( Nyeoe ea sesebedisoa);
Setšoantšo sa 1 Host Panel
1. Boema-kepe ba ho theola 2. 0-2mA ea hajoale 3. 2-10mA ea hajoale
4. Antenna sucker 5. Wireless synchronization port 6. Wire synchronization port
7. Konopo ea ON/OFF 8. Kou ea ho tjhaja 9. Letšoao la matšoao
10. Pontšo ea matla 11. Fan 12. Khokahano ea USB 13. Thepa ea 'mala oa LCD skrine 14.Printer
Setšoantšo sa 2 PT Voltage Emitter
1. Konopo ea ON / OFF 2. Boema-kepe ba ho tjhaja 3. Letšoao la matla
4. Antenna sucker 5. Letšoao la pontšo 6. Boema-kepe
7. Boema-kepe ba fatše 8. Kou ea puisano pakeng tsa moeti le PT voltage emitter 9. PT voltage input
Moamoheli | 1pc |
Nyeoe ea lisebelisoa | 1pc |
PT e emitter ea motlakase | 1pc |
Cable ea hajoale ea liteko | 3pcs |
Cable ea tlhahlobo ea motlakase | 1pc |
Cable ea fatše | 2pcs |
Puisanothapo | 1pc |
Antenna | 2pcs |
Charger | 2pcs |
Pampiri ea khatiso | 2 rolls |
Mosebedisi'smselemo | 1pc |
Tlaleho ea teko | 1pc |