GDWS-311RC SF6 Khase Dew Point Tester
GDWS-311RC ke sesebelisoa se loketseng ho lekola phoka ea khase ea SF6.Karolo ea mantlha ke li-sensor tsa DRYCAP tse hlahisoang ke k'hamphani ea Vaisala ea Finland.Ka li-chips tsa profeshenale le li-algorithms tsa software tse ntle haholo tsa STMicroelectronics, re hlahisitse moloko o mocha oa sesebelisoa sa tlhahlobo ea mongobo oa khase.
●Tlhokomelo ea mongobo ea thepa ea motlakase ea khase ea SF6 bakeng sa matla a motlakase
●Teko ea boleng ba khase ea SF6 cylinder gas
●Tlhahiso e phahameng ea khase e hloekileng
●Phepelo ea khase e omileng indastering ea semiconductor
●Tšebeliso ea lipatlisiso le nts'etsopele
●Tlhokomelo ea kamore e hloekileng / ntlo e omileng
●Sebaka sa phekolo ea mocheso oa tšepe le ho lemoha mongobo oa khase ea laboratori ea indasteri, joalo ka moea, CO2, N2, H2, O2, SF6, He, Ar le likhase tse ling tse sa sebetseng.
●E betere ho feta ±2℃ ho nepahala ha tekanyo.
●Litsela tsohle tsa khase ke moralo oa thepa ea polymer, e netefatsa hore ha ho na letho le leketlileng la metsi mme e netefatsa lebelo la tlhahlobo.
●Valve e laolang 'mele oa tšepe e se nang oli e se nang oli e sebelisoa ho netefatsa ho nepahala ha boleng bo lekantsoeng.
●Li-algorithms tsa software tse tsoetseng pele li ntlafatsa ho nepahala ha liteko tsa li-sensor.
●Tharollo ea tlhophiso ea chassis e kopantsoeng, basebelisi ba ka kopanya lisebelisoa le lisebelisoa tse amanang habonolo.Pakete e akaretsang e etsoa, e etsang hore mosebelisi a be le boiphihlelo bo khutsitseng.
●Qala tlhahlobo, ha ho na tlhoko ea ho futhumatsa le ho oscillate.
●Phetoho ea mocheso le tokiso ea data ea khatello.
●Theknoloji ea khomphutha e makatsang.
●Matla a matla a matla a betri ea lithium, hlokomela phepelo ea matla a mabeli a AC le DC.Ha ho na motlakase oa AC o hlokahalang sebakeng sa marang-rang.Phepelo ea matla a betri ea lithium e ntse e tsoela pele ho sebetsa lihora tse fetang 8 ntle le tlhoko ea matla a kantle.
●Moralo oa potoloho ea litšitiso tsa anti-electromagnetic ho netefatsa ts'epahalo ea sehlahisoa.
●Mosebetsi oa ho tsosolosa khase, o sebelisana le tikoloho.
●Lintlha tsa tlhahlobo li tsitsitse 'me li ka fana ka litekanyetso tse tloaelehileng tsa phoka le boleng ba phoka bo fetotsoeng ho 20℃.
●Sebaka se setle ka ho fetisisa sa phallo ea teko se bontša hore mosebedisi a ka fetola phallo ea khase ka mokhoa o hlakileng le ka potlako.Fokotsa nako ea teko.
●Mohaho o kenang moeeng o entsoe ka motsoako o monyenyane oa ho itšireletsa, 'me tsela ea moea e lokelang ho lekoa e ke ke ea tsoa ha tsela ea moea e khaotsoe.
●Mokhoa oa ho lekanya: Molao-motheo oa tekanyo ea Resistive le Capacitive
●Litekanyo: ntlha ea phoka -80℃--+20℃(support ppmv)
●Ho nepahala: ±2℃
(ha mocheso oa phoka o le ka tlase ho 0 ℃, tlhahiso ea sensor ke ntlha ea serame)
●Nako ea ho arabela: 63% [90%]
+20→-20℃ Td 5s[45s]
-20→-60℃ Td 10s[240s]
●Qeto: 0.01 ℃
●Pheta-bokhoni: ± 0.5℃
●Pontšo: ℃, ppm, ℃P20 (boleng bo fetotsoeng ho 20 ℃)
●Phallo ea khase: 400-600ml / min
●Pontšo ea ho phalla: 0-1000mL digital flow meter
●Mohlala oa khatello ea khase: ≤1MPa
●Phepelo ea matla: 220VAC ± 10%, 50Hz, tšebeliso ea AC/DC, ho sebetsa ho tsoelang pele ha ho ka tlase ho lihora tse 8.
●Sebelisa mocheso oa tikoloho: -20-+60℃
●Mongobo wa tikoloho: 90%RH
●Tšusumetso ea boleng ba tekanyo: Ha ho na tšusumetso ea khatello le phallo
●Boima: 395 * 295 * 155mm
●Boima ba 'mele: hoo e ka bang 2kg
Sehlopha se seholo | 1 sengoathoana |
Adapter | 1 beha |
Pipe ea Teflon (e kenyelletsa valve ea phetoho ea phallo le sehokelo se potlakileng) | 1 beha |
Pipe ea mohatla | 1 beha |
Likarolo tsa tlatsetso | 1 beha |
Charger | 1 sengoathoana |
Mosebedisi's Tataiso | 1 kopitsa |
Tlaleho ea Tlhahlobo | 1 kopitsa |