GDP-8000CM SF6 Gesi Dew Point Tester (Mokhoa oa Seipone se Chilled)
GDWS-311CM ke sesebelisoa se loketseng ha ho hlokahala ho etsa tlhahlobo ea metsi a khase ea SF6.Sensor ea karolo ea mantlha e hlahisoa ke k'hamphani ea GE.Ka li-chips tsa profeshenale le li-algorithms tsa software tse ntle haholo tsa STMicroelectronics, re hlahisitse moloko o mocha oa sesebelisoa sa tlhahlobo ea mongobo oa khase.
●Tlhokomelo ea mongobo ea thepa ea motlakase ea khase ea SF6 bakeng sa matla a motlakase.
●Teko ea boleng ba khase ea SF6 cylinder gas
●Tlhahiso e phahameng ea khase e hloekileng
●Phepelo ea khase e omileng indastering ea semiconductor
●Tšebeliso ea lipatlisiso le nts'etsopele
●Tlhokomelo ea kamore e hloekileng / ntlo e omileng
●Sebaka sa phekolo ea mocheso oa tšepe le ho lemoha mongobo oa khase ea laboratori ea indasteri, joalo ka moea, CO2, N2, H2, O2, SF6, He, Ar le likhase tse ling tse sa sebetseng.
●E betere ho feta ±2℃ ho nepahala ha tekanyo.
●Moralo oohle oa thepa ea mochini oa polymer, o netefatsa hore ha ho na letho le leketlileng la metsi mme o netefatsa lebelo la tlhahlobo.
●Valve e laolang 'mele oa tšepe e se nang oli e se nang oli e sebelisoa ho netefatsa ho nepahala ha boleng bo lekantsoeng.
●Li-algorithms tsa software tse tsoetseng pele li ntlafatsa ho nepahala ha liteko tsa li-sensor.
●Tharollo ea tlhophiso ea chassis e kopantsoeng, basebelisi ba ka kopanya lisebelisoa le lisebelisoa tse amanang habonolo.Pakete e akaretsang e etsoa, e etsang hore mosebelisi a be le boiphihlelo bo khutsitseng.
●Qala tlhahlobo, ha ho hlokahale hore u be le preheat lesisinya.
●Phetoho ea mocheso le tokiso ea data ea khatello.
●Theknoloji ea khomphutha e makatsang.
●Matla a matla a matla a betri ea lithium, hlokomela phepelo ea matla a mabeli a AC le DC.Ha ho na motlakase oa AC o hlokahalang sebakeng sa marang-rang.Phepelo ea matla a betri ea lithium e ntse e tsoela pele ho sebetsa lihora tse fetang 8 ntle le tlhoko ea matla a kantle.
●Moralo oa potoloho ea litšitiso tsa anti-electromagnetic ho netefatsa ts'epahalo ea sehlahisoa.
●E ka holisa puisano ea USB, puisano ea serial, module ea puisano e se nang mohala, le ho hlokomela mesebetsi ea puisano le khatiso ea komporo e holimo.
●Mohopolo o nang le bokhoni bo boholo, o ka hlokomelang lihlopha tse 1000 tsa mesebetsi ea polokelo ea data.
●Ts'ebetso ea ho lokisa tsela ea khase e ka sebelisoa ho hloekisa lipeipi tsa tlhahlobo pele ho mosebetsi oa tlhahlobo ea masimong, e khutsufatsang nako ea teko.(ka boikhethelo)
●Sesebelisoa se na le ts'ebetso ea tlhahlobo ea khase ho khutlisa khase ea tekanyo ea sulphur hexafluoride.
●Lintlha tsa tlhahlobo li tsitsitse 'me li ka fana ka litekanyetso tse tloaelehileng tsa phoka le boleng ba phoka bo fetotsoeng ho 20℃.
●Sebaka se setle ka ho fetisisa sa phallo ea teko se bontša hore mosebedisi a ka fetola phallo ea khase ka mokhoa o hlakileng le ka potlako.Fokotsa nako ea teko.
●Mohaho o kenang moeeng o entsoe ka motsoako o monyenyane oa ho itšireletsa, 'me tsela ea moea e lokelang ho lekoa e ke ke ea tsoa ha tsela ea moea e khaotsoe.
Mokhoa oa ho lekanya | Chilled Seipone Mokhoa |
Lekhalo la litekanyo | phoka -110℃--+20℃(support ppmv) |
Ho nepahala | ± 2 ℃ (ha mocheso oa phoka o le ka tlase ho 0 ℃, tlhahiso ea sensor ke ntlha ea serame) |
Nako ea ho arabela | 63% [90%] +20→-20℃ Td 5s[45s] -20→-60℃ Td 10s[240s] |
Qeto | 0.01℃ |
Pheta-pheta | ± 2 ℃ |
Pontšo yuniti | ℃, ppm, ℃P20(boleng bo fetotsoeng ho 20 ℃) |
Phallo ea khase | 400-600ml / min |
Pontšo ea ho phalla | 0-1000mL phallo ea dijithale |
Mohlala oa khatello ea khase | ≤1MPa |
Phepelo ea motlakase | 220VAC ± 10%, 50Hz, ts'ebeliso ea AC/DC, ts'ireletso ea tefiso e feteletseng, ho sebetsa ho tsoelang pele ha ho tlase ho feta 8hours. |
Sebelisa mocheso oa tikoloho | -20-+60 ℃ |
Mongobo wa tikoloho | 90% RH |
Tšusumetso ea boleng ba tekanyo | Ha ho na tšusumetso ea khatello le phallo |
Boemo | 395*295*155mm |
Boima ba 'mele | hoo e ka bang 2kg |