GDW-102 Oil Dew Point Tester (Coulometric Karl Fischer Titrator)
Theknoloji ea Coulometric Karl Fischer e sebelisoa ho lekanya ka mokhoa o nepahetseng ho latela mohlala oa mongobo oo sampole e lekantsoeng e nang le eona.Theknoloji e sebelisoa haholo bakeng sa ho nepahala le litšenyehelo tse theko e tlaase tsa teko.Moetso oa GDW-102 o lekanya ka nepo mongobo lisampoleng tsa mokelikeli, tse tiileng le tsa khase ho latela theknoloji.E sebelisoa ka motlakase, petroleum, lik'hemik'hale, lijong joalo-joalo.
●Sebelisa potoloho e ntlafalitsoeng ea electrolysis ea PWM ho fokotsa ho felloa ke matla ha sesebelisoa.
●Letšoao le phahameng le nepahetseng la ho lekanya li-electrode le tlhahlobo ea potoloho li etsa qeto ea ho qetela ea electrolytic kapele le ka mokhoa o nepahetseng ka bokhoni bo matla ba ho thibela tšitiso.
●Sebelisa mekhoa ea matšeliso a hona joale a se nang letho a electrolyte le puseletso ea electrolyte balance drift ho rala sephetho sa tlhahlobo.
●E hahiloe ka mekhoa e meraro ea lipalo ho hlahisa tlaleho ka bo eona.
●Likonopo tse laolang lebelo la ho kopanya li na le lebelo le leshome (0 ~ 9speed).
●Lekanya phoso ea "electrode open-circuit" le phoso ea potoloho e khuts'oane ka bo eona.
●E ka boloka lirekoto tsa nalane tse 256 ka nako.
●Oache ea khalendara e nang le thempereichara e ka boloka letsatsi le nako ea tlhahlobo ka nepo, e ka sebetsang lilemo tse 10 holimo ha motlakase o theohile.
●Ha sesebelisoa se sa sebetse nako e telele, skrine ea LCD e tla koala ka boeona ho sireletsa skrine le ho boloka bophelo ba skrine.Tobetsa likonopo life kapa life ho tlohela ts'ireletso ea skrineng.
●Ho na le RS232 segokanyimmediamentsi sa sebolokigolo ho hokela le PC le mini-printer habonolo.
Electrolysis hona joale | Max.400mA |
Electrolysis e phahamenglebelo | Max.2.4mg/min |
Lekhalo la ho lekanya | 10ug~100mg |
Kutloisiso | 0.1ug |
Nepahalo | ±3ug bakeng sa 10ug~1mg RSD 0.3% kapa ka tlase ho 1mg kapa ho feta |
Ambient Mocheso | 5~35℃ |
Mongobo wa tikoloho | ≤85% RH |
Phepelo ea motlakase | AC220V±20% 50HZ±10% ,40VA |
Litekanyo | 270×210×125(mm) |
Boima ba 'mele | 5kg |
Boholo ba tšebeliso ea matla | 30W |
Sehlopha se seholo | 1 sengoathoana |
Electrolysis electrode | 1 sengoathoana |
Electrode ea tekanyo | 1 sengoathoana |
Nate e hlohlelletsang | 2 likhomphutha |
Karolo ea silika ea gel | 1 sengoathoana |
Matheba a silika a gel | 10 likhomphutha |
0.5μl Mohlala oa ente | 1 sengoathoana |
50μl ente ea mohlala | 1 sengoathoana |
1ml ente ea mohlala | 1 sengoathoana |
Ho omisa tube | 1 sengoathoana |
Thapo ea matla | 1 sengoathoana |
Setlolo sa vacuum | 1 sengoathoana |
Electrolyte | 1 sengoathoana |
Tataiso ea mosebelisi | 1 khopi |
Tlaleho ea tlhahlobo ea fektheri | 1 khopi |