GDSF-311WPD 3-In-1 SF6 Analyzer ea Khase
GDSF-311WPD (GDSF-411WPD) ke sesebelisoa se loketseng ha ho hlokahala ho hlahloba metsi, ho hloeka le lihlahisoa tsa ho bola ha khase ea SF6.Karolo ea mantlha ea tlhahlobo ea phoka ke li-sensor tsa DRYCAP® tse hlahisoang ke k'hamphani ea Vaisala ea Finland.Sensor ea tlhahlobo ea khase ea infrared SF6 e entsoeng ke European Sensor Company e sebelisetsoa ho leka bohloeki ba khase ea SF6.Sensor ea electrochemical e entsoeng ke K'hamphani ea Mombabo naheng ea Switzerland e sebelisoa e le sesebelisoa sa ho lemoha tlhahlobo ea lihlahisoa tsa SF6 tsa ho bola.Ka li-chips tsa profeshenale le li-algorithms tsa software tse ntle haholo tsa STMicroelectronics, re hlahisitse moloko o mocha oa 3-in-1 analyzer ea khase.
SF6Mongobo
●Mokhoa oa ho lekanya: Molao-motheo oa tekanyo ea Resistive le Capacitive
●Litekanyo: ntlha ea phoka -80℃--+20℃(support ppmv)
●Ho nepahala: ±1℃
(ha mocheso oa phoka o le ka tlase ho 0 ℃, tlhahiso ea sensor ke ntlha ea serame)
●Nako ea ho arabela: 63% [90%]
+20→-20℃ Td 5s[45s]
-20→-60℃ Td 10s[240s]
●Qeto: 0.01 ℃
●Pheta-pheta: ± 0.5 ℃
●Pontšo: ℃, ppm, ℃P20 (boleng bo fetotsoeng ho 20 ℃)
●Phallo ea khase: 400-600ml / min
●Pontšo ea ho phalla: 0-1000mL digital flow meter
●Mohlala oa khatello ea khase: ≤1MPa
SF6Bohloeki
●Mokhoa oa ho lekanya: Molao-motheo oa Tekanyo ea Infrared (NDIR series sensors)
●Lethathamo la ho lekanya: 0 ~ 100% SF6
●Nako ea karabelo: [90%] 60s
●Ho nepahala: ± 0.5%FS
●Pheta-pheta: ± 0.5%
●Qeto: 0.01%
●Pontšo: %
SF6Lihlahisoa tsa ho bola
●Mokhoa oa ho lekanya: Molao-motheo oa Tekanyo ea Electrochemical (Li-sensor tsa Electrochemical series)
●Lethathamo la tekanyo: H2S: 0 ~ 200ppmv
SO2: 0 ~ 200ppmv
CO: 0 ~ 500ppmv
HF: 0 ~ 50ppmv
●Ho nepahala: H2S: 10ppmv ±3%
SO2: 10ppmv ±3%
CO: 50ppmv ±4%
HF: 10ppmv ±3%
●Pheta-pheta: H2S: 10ppmv ± 2%
SO2: 10ppmv ±2%
CO: 50ppmv ±2%
HF: 10ppmv ±2%
●Qeto: 0.01ppmv
●Sesebelisoa sa pontšo: ppmv
●Phepelo ea motlakase: 220VAC ± 10%, 50Hz, ts'ebeliso ea AC/DC, ts'ireletso ea tefiso e fetelletseng, ts'ebetso e tsoelang pele ha e tlase ho 8hours.
●Sebelisa mocheso oa tikoloho: -20-+60℃
●Mongobo wa tikoloho: 90%RH
●Tšusumetso ea boleng ba tekanyo: Ha ho phello ea khatello le phallo
●Boima: 395 * 295 * 155mm
●Boima ba 'mele: hoo e ka bang 2kg.
Tlhaloso: GDSF-411WPD SF6Lihlahisoa tsa ho bola
●Ho nepahala: H2S: <10ppmv ± 0.3ppmv;>10ppmv ±3%
SO2: <10ppmv ± 0.3PPmv;>10ppmv ±3%
●Pheta-pheta: H2S: <10ppmv ± 0.2ppmv;>10ppmv ±2%
SO2: <10ppmv ± 0.2PPmv;>10ppmv ±2%
●Mosebetsi oa ho tsosolosa le ho tlatsa: kamore ea ho tsosolosa 2L,nako ea ho tsosolosa ≤ 5min
Ka mosebetsi oa ho omisa khase
●Boima: 395 * 295 * 315mm
●Boima ba 'mele: hoo e ka bang 5kg.
Mohlahlobi ea ka Sehloohong | 1 sengoathoana |
Adapter | 1 beha |
Pipe ea Teflon (e kenyelletsa valve ea phetoho ea phallo le sehokelo se potlakileng) | 1 beha |
Pipe ea mohatla | 1 beha |
Likarolo tsa tlatsetso | 1 beha |
Charger | 1 sengoathoana |
Mosebedisi's Tataiso | 1 sengoathoana |
Tlaleho ea Tlhahlobo | 1 sengoathoana |