GDOT-80C Insulation Oil Breakdown Tester 80kV
Ho na le palo e kholo ea lisebelisoa tsa motlakase tsamaisong ea matla, tsamaiso ea literene le merafong e meholo ea limela tsa petrochemical le likhoebo, ho kenella ka hare ho tsona hangata ho tletse oli.Matla a dielectric a oli e sireletsang ke teko e tlamang ea tloaelo.E le ho fihlela litlhoko tsa 'maraka, k'hamphani ea rona e ntlafalitse le ho hlahisa letoto la lisebelisoa tsa ho hlahloba matla a dielectric oli dielectric ho latela maemo a IEC156 "Insulating oil-determination of dielectric strength" le boemo ba indasteri ea naha DL-474 · 4-92DL/T596 -1996 "Khoutu e thibelang ea teko ea lisebelisoa tsa motlakase".
Sesebelisoa sena se nka microcomputer e le 'ngoe e le motheo, e hlokomela boiketsetso bohle ba tlhahlobo, e na le ho nepahala ha tekanyo e phahameng, e ntlafatsa haholo ts'ebetso ea mosebetsi,' me e fokotsa haholo matla a basebetsi.Ka nako e ts'oanang, sesebelisoa se na le ponahalo e kopanetsoeng 'me se loketse ho jara.
●E amohela microprocessor hore e phethe ka bo eona ts'ebetso ea ho matlafatsa, ho ts'oara, ho sisinyeha, ho tsitsisa, ho bala, ho hatisa, joalo-joalo, 'me e ka tsamaisa phepelo ea oli e mamella tlhahlobo ea voltage ho 0-80 kV.
●Senoelo sa oli sa sesebelisoa se thehoa ka nako e le 'ngoe ea ho lahlela khalase e khethehileng, e thibelang tšitiso e kang ho tsoa ha oli.
●Moralo o ikhethileng oa lisampole tse phahameng tsa sesebelisoa o lumella boleng ba tlhahlobo ho kenya converter ea A / D ka kotloloho, ho qoba liphoso tse bakoang ke potoloho ea analog, le ho etsa hore liphetho tsa tekanyo li nepahale haholoanyane.
●Litekanyetso tsa ho etsa liteko tsa lisebelisoa li kenyelletsa maemo a indasteri, maemo a naha le maemo a kantle ho naha, mme ts'ebetso e bonolo ebile e bonolo.
●E nang le matla a mangata, over-current, limit le ts'ireletso e 'ngoe ho netefatsa polokeho ea basebetsi.'Me e na le bokhoni bo matla ba ho thibela ho kena-kenana le ts'ebetso e ntle ea motlakase.
●Matla a tsoang: 0-80kV
●Sekhahla sa ho sotha matla: <1%
●Matla: 1.5kVA
●Mohope oa oli: 240ml
●Ho nepahala ha tekanyo: ± 3%
●Voltage e eketsehasekhahla: 2kV/s, 3kV/s boikhethelo, phoso: 0.2kV/s
●Kenyelletso ea matla: AC220V± 20%, 50Hz±5Hz
●Matla: <200W
●Mocheso o sebetsang: 0-40 ℃
●Mongobo: <85%RH
●Boima: 430 * 350 * 370mm
Sesebelisoa sa GDOT-80C | 1 sengoathoana |
Komiki ea oli (250ml) | 1 sengoathoana |
Thapo ea matla | 1 sengoathoana |
Cable ea fatše | 1 sengoathoana |
Fuse e se nang letho | 2 sengoathoana |
Nate e hlohlelletsang | 2 sengoathoana |
E tloaelehileng 2.5mm | 1 sengoathoana |
Tweezer | 1 sengoathoana |
Pampiri ea ho hatisa | 1 meqolo |
Tataiso ea mosebelisi | 1 khopi |
Tlaleho ea tlhahlobo ea fektheri | 1 khopi |
Electrode e 'ngoe ke ea boikhethelo