GDJB-6000M Smart Substation Relay Protection System System
GDJB-6000M Smart Substation Relay Test System ke moloko o mocha oa teko ea tšireletso ea relay e entsoeng ho latela "Smart Substation Relay Protection Technical Specifications" le "Smart Substation Technical Guidelines".E ke ke ea hlokomela feela tlhahlobo e felletseng ea ts'ebetso ea sesebelisoa sa ts'ireletso ea dijithale (IEC61850, seteishene se bohlale sa dijithale), empa hape se etsa tlhahlobo e felletseng ea ts'ebetso ho sesebelisoa sa ts'ireletso sa setso (seteishene se tloaelehileng).
GDJB-6000M ke sehlahisoa se secha se nkehang habonolo se ntlafalitsoeng ka boikemelo ka ts'ebeliso ea mahlale a joalo ka lisebelisoa tse kentsoeng tsa nako ea nnete, li-processor tse kentsoeng tse sebetsang hantle haholo, le lisebelisoa tse kholo tsa logic, tse kopantsoeng le maemo a matla a matla le liphihlelo tse ngata tsa basebelisi ba matla.E sebetsa haholo ho lifeme tsa motlakase, litsi tse nyane, baetsi ba lisebelisoa, likhoebo le litsi, hammoho le litsi tse ling tsa lipatlisiso tse hlokang ho etsa liteko kapa tlhahlobo ea ts'ireletso ea phepelo.
GDJB-6000M e amohela leano la tsamaiso ea boenjiniere ho laola tlhahlobo;tsamaiso ea morero e amohela mohlala oa mekhahlelo e meraro ea thepa ea tšireletso, mofuta oa tšireletso, le ntlha ea teko ho laola teko.Sebopeho se hlakile haholo;E ts'ehetsa tlhahiso ea analog, 'me ka nako e ts'oanang e ka etsa tlhahiso ea bongata ba analog le ho romella le ho amohela melaetsa ea GOOSE;E fana ka mekhoa e mengata ea ho lokisa melaetsa ea SV le GOOSE, ho kenyelletsa le litlhophiso tsa matsoho, ho lemoha marang-rang, le ho kenya lifaele tsa SCL;Molaetsa oa optical digital o na le tlhophiso e feto-fetohang haholo ea transceiver, e ka romellang melaetsa e mengata ea SV le GOOSE ka 1 optical port, 'me melaetsa e tšoanang ea SV le GOOSE e ka romelloa ka li-ports tse ngata tsa optical.
DL/T 860 Series Standard "Substation Communication Network le System"
DL/T 624-2010 "Maemo a Technical bakeng sa Tšireletso ea Relay Tšebeliso ea Lisebelisoa tsa Teko tsa Microcomputer"
GBT 7261-2008 "Mokhoa oa Motheo oa Teko bakeng sa Tšireletso ea Relay le Lisebelisoa tse Ikemetseng tsa Tšireletso"
IEC 60255-24: 2001 "Li-relay tsa motlakase - Karolo ea 24: Sebopeho se tloaelehileng bakeng sa phapanyetsano ea data ea nakoana (COMTRADE) bakeng sa lisebelisoa tsa matla"
●Smart Test Module
Tlhophiso e bohlale ea thempleite ea liteko e ea tšehetsoa.Lintho tsa liteko li ka eketsoa ka mokhoa o sa reroang nakong ea ts'ebetso ea liteko 'me tsa bolokoa e le lifaele tsa projeke tse ka sebelisoang hape ho ntlafatsa katleho ea tlhahlobo mothating oa ho qetela oa tlhahlobo le ho felisa.Mesebetsi e matla ea software.Pontšo ea nako ea sebele ea waveform, max.Tlhōrō le sebaka.Software e ka hlahloba le ho sekaseka mofuta o itseng oa maqhubu.Windows e ka atametsoa kahare le kantle.Lintlha tsa karolo e le 'ngoe li ka hlahlojoa 'me li ka hlahlojoa ka har'a sebopeho sa maqhubu a ho ntša metsi.
●Teko e iketsang
Ka ts'ireletso ea sebaka sa marang-rang le ts'ireletso ea dijithale ts'ebetso ea tlhahlobo ea othomathike, lisebelisoa tsohle tsa tlhahlobo ea sesebelisoa se le seng sa ts'ireletso li ka phethoa ka senotlolo se le seng. Lintlha tsa tlhahlobo le waveform ea phepelo ea phepelo ea nakoana e ka bolokoa ka bo eona kapa ka letsoho.
●Digital/analoge e hlahisoang
E ka leka yuniti e kopanyang, ts'ireletso, tekanyo le lisebelisoa tsa taolo, le liteishene tse bohlale tsa liteishene tse nyane tsa dijithale, hape e ka leka lisebelisoa tse kang ts'ireletso ea analog le yuniti ea transformer.
●Phallo ea nako e le 'ngoe ea bongata ba analog le digital
E ts'ehetsa tlhahiso ea analoge ka nako e le 'ngoe le ho romella le ho amohela molaetsa oa GOOSE.
● Mekhoa e mengata ea ho hlahloba
E ts'ehetsa amplitude, phase, frequency, impedance, vector, tatellano, le matla li etsoa ka tlhahlobo ea matsoho kapa ea othomathiki, hape e ts'ehetsa tlhahlobo ea phetoho ea othomathike ho latela mokhoa oa gradation, slip le synthesis.
● Polokeho le alamo
Ka ho futhumala ho feteletseng le ts'ireletso ea morao-rao, mohloli oa hona joale o na le ts'ireletso ea potoloho e bulehileng le ts'ebetso ea alamo, 'me mohloli oa motlakase o na le ts'ebetso e feteletseng le ts'ireletso ea nako e khutšoanyane.
● Sebopeho sa setšoantšo sa Virtual Terminal
Ts'ehetsa ts'ebetso ea ponts'o ea li-terminal graphical, phallo ea data e hlakile.
●Romela le ho amohela melaetsa ka nako e le nngwe
Ts'ehetso ea IEC61850-9-1, IEC61850-9-2 le GOOSE optical digital message output.Letšoao la GOOSE le ka romelloa le ho amoheloa ka boithaopo, hape le ka romela le ho amohela ka sebopeho sa optical Ethernet le IEC 61850-9-2.
● FT3/E Atolositsoe FT3
Tšehetsa FT3, FT3 e atolositsoeng le tlhahiso ea molaetsa oa DL/T 282, le ho tšehetsa 2M/4M/6M/8M/10M sekhahla sa khouto ea UART le khouto ea 5M/10M/20M ea Manchester.
● Teko e sa tloaelehang
Ka ts'ebetso e sa tloaelehang ea molaetsa oa analog, e ka etsisa ho se tloaelehe ka boleng, ho romella jitter khafetsa, ho lieha ka mokhoa o sa tloaelehang, tahlehelo ea pakete, ho tsoa mohatong, ho tlola nomoro ea serial, mokhoa oa tlhokomelo, phetoho ea maemo le liteko tse ling.
● Ho bapala ka phoso
E ts'ehetsa papiso ea liphoso le ts'ebetso ea ho bapala ea fomate ea COMTRADE.
● Tšebeletso ea MMS
Ka mosebetsi oa ho bala le ho ngola oa MMS, o khona ho bala le ho ngola litlhophiso tse bohlale tsa lisebelisoa tsa IED le lintlha tse ling tsa tlhophiso.
● Kamahanyo ya nako le ho fana ka nako
Ka ts'ebetso ea synchronous trigger, ts'ehetso ea phihlello e tobileng ho GPS / BD antenna bakeng sa khokahano ea nako, e boetse e ts'ehetsa mokhoa oa nako oa IRIG-B, PPS le PTP 1588 mme e ka ts'ehetsa tlhahiso ea kantle ea IRIG-B, PPS le PTP 1588 e fanang ka pontšo.
● Khokahano e thata ea binary input le tlhahiso ea binary
Litlhaloso tse kentsoeng lia sebetsa 'me li sa sebetse feela, 'me mofuta oa ho kenya le motlakase li lemohuoa ka bohona.Likanale li arotsoe ho tse ling, 'me khokahano ea polarity e khutlisetsa morao ka potlako ea alamo.
●Ho amohela le ho sekaseka melaetsa
Ka ts'ebetso ea ho amohela le ho sekaseka molaetsa, molaetsa o amoheloang o ka buloa ka ZHNPA bakeng sa tlhahlobo kapa kantle ho naha.
●Mokhoa o le mong oa fiber
Optical port e ts'ehetsa phetiso ea fiber e le 'ngoe le kamohelo ea fiber e le' ngoe hape e ts'ehetsa tlhahlobo ea matla a mahlo.
●Letšoao le lenyenyane la analoge
E na le segokanyimmediamentsi sa sebolokigolo sa matshwao a manyane, tshehetso ya 12 tsela ya analoge pontsho e nyane ya letshwao, e ka lekanya -7V~ 7V AC voltage, e tshehetsa 12 tsela ya pontsho e nyane ya analoge, mme e ka ntsha -7V~ 7V AC voltage.
●Ts'ebetso ea ho ama
E na le ponts'o e phahameng ea 10.4 inch e tšehetsang ts'ebetso ea ho ama.
●Khokahano e se nang mohala
Fana ka tšebetso ea teko e hole, e nang le mojule oa WiFi, e bonolo ho mosebedisi.
Mohloli oa motlakase oa AC | Range: 6 × 120 V, 120V / 60VA ka tsela Ho nepahala: ± 10mV ho 0.2 ~ 2V;± 0.2% ho 2V ~ 120V Qeto: 1mV |
Mohloli oa hona joale oa AC | Range: 6 × 30A, 30A / 150VA ka tsela Ho nepahala: ± 10mA bakeng sa 0 ~ 500mA;± 0.2% bakeng sa 500mA ~ 30A Qeto: 1mA |
Mokhahlelo oa tlhahiso | Sebaka: 0 ~ 360 ° Ho nepahala: ±0.1° Qeto: 0.1 ° |
Nako ea tlhahiso | Boemo: 0 ~ 1000Hz Ho nepahala:<±0.001Hz (0~65Hz) <±0.01Hz(65~450Hz) <±0.02Hz (450~1000Hz) Qeto: 0.001 Hz |
Mohloli oa motlakase oa DC | Range: 6 tsela, tsela ka 'ngoe 0 ~ 130V / 60VA Ho nepahala: 0.2% |
DC ea hona joale mohloli o hlahisoang | Range: 6 tsela, tsela ka 'ngoe 0 ~ 20A / 100VA Ho nepahala: 0.2% |
Khokahano ea puisano ea IEC 61850 | Palo ea likou: lipara tsa 6 ke 100M adaptive;2 lipara ke 100/1000M adaptive Mofuta oa Sehokelo: LC Wavelength: 1310nm |
Khokahano ea puisano ea IEC 60044 | Palo ea likou: likou tse 6 tse fetisang, tse 2 li amohela likou Mofuta oa Sehokelo: ST Wavelength: 850nm |
Sehokelo sa kamahanyo | Bongata: 1 * GPS / BD ANT;2 *IRIG-B/PPS lets'oao la optical-1 bakeng sa ho beha nako, 1 bakeng sa ho fana ka nako;2 lipara* IRIG-B/PPS matshwao a motlakase-1 para ea nako, para e le 1 ea ho fana ka nako;1 para * IEEE 1588; Mofuta oa li-interface: GPS / BD ANT, IRIG-B / PPS pontšo ea optical;IRIG-B / PPS pontšo ea motlakase;EEE 1588 |
Tekanyo ea nako | Mefuta: 10ms~9999.999s Ho nepahala: 1ms |
Fetosa ho kenya | Palo: lipara tse 8 Matla a sitisang: DC250V/0.5A |
Fetola tlhahiso | Palo: lipara tse 6, tseo lipara tse 2 e leng tsa ho bula kapele |
Khokahano e se nang mohala | Mofuta oa Sehokelo: WIFI |
Khokahano ea mohala (sehokelo sa puisano sa Ethernet) | Palo ea likou: l 2 Mofuta oa sehokelo: 100 megabytes LAN port, RJ45 |
Phepelo ea motlakase | Voltage: AC/DC 220V, ho kheloha ho lumellehang: -20% ~ 15% Fnako: 47 ~ 65 Hz |
Letšoao le lenyenyane la analoge | Palo ea likanale: 12 tsela; Mofuta oa Sebopeho: Plug ea Aviation, AC Voltage |
Sehlahisoa se senyenyane sa analoge | Palo ea likanale: 12 tsela; Mofuta oa Sebopeho: Plug ea Aviation, AC Voltage |
Sehokelo sa USB | Palo: 2 |
Maemo a tikoloho ea mosebetsi | Mocheso o sebetsang: -20°C~70°C Mongobo: ≤95%, ha ho na condensation |
Ba bang | Boima: 15 kg Boholo: 360×480×190(mm) Khokahano ea Marang-rang: RJ45 Pontšo: 10.4 inchskrine se thetsoang1024 * 768 'mala oa' nete oa LCD pontšo |