GDCR3000B Digital Resistance Tester

GDCR3000B Digital Resistance Tester

Tlhaloso e Khutšoanyane:

GDCR3000B Earth Resistance/Soil Resistivity Tester e etselitsoe ka ho khetheha ho lekanya khanyetso ea lefatše, ho hanyetsa mobu, matla a lefatše le motlakase oa AC.Theknoloji ea morao-rao ea digital le micro processing e amoheloa, ho lekanya khanyetso ea lefats'e ka 4-pole, 3-pole kapa 2-pole.

 


Lintlha tsa Sehlahisoa

Li-tag tsa Sehlahisoa

Lintlha tse akaretsang

GDCR3000B Earth Resistance/Soil Resistivity Tester e etselitsoe ka ho khetheha ho lekanya khanyetso ea lefatše, ho hanyetsa mobu, matla a lefatše le motlakase oa AC.Theknoloji ea morao-rao ea digital le micro processing e amoheloa, ho lekanya khanyetso ea lefats'e ka 4-pole, 3-pole kapa 2-pole.Theknoloji ea FFT(Fourer transform), AFC(automatic frequency control) e boetse e fumaneha, e nang le bokhoni bo botle ba ho thibela tšitiso le bokhoni ba ho ikamahanya le tikoloho, ho netefatsa ho nepahala ho phahameng, botsitso bo phahameng le ho tšepahala.E sebelisoa haholo ho lekanya matla a motlakase, mehala, meteorology, lebala la oli, kaho, ts'ireletso ea mabone, lisebelisoa tsa motlakase tsa indasteri.

GDCR3000B e entsoe ka mochini o amohelang, software ea ho beha leihlo, likhoele tsa tlhahlobo, molamu oa mobu o thusang, mohala oa puisano le tse ling.Pontšo e kholo ea LCD ea mochini o amohelang o na le lebone le leputsoa le graph ea bar e bonts'ang hore e ka bonoa ka ho hlaka.Ka nako e ts'oanang e ka boloka lisebelisoa tsa 300 tsa data, ea hlokomela potso ea histori le mesebetsi ea ho shebella nako ea sebele ea inthaneteng ka ho shebella software, pontšo e matla, pontšo ea alamo, ka mesebetsi ea ho bala, ho hlahloba, ho boloka, ho tlaleha le ho hatisa lintlha tsa histori.

Litlhaloso

1. Boemo bo Tloaelehileng le Boemo ba Mosebetsi

  Boemo bo Tloaelehileng Boemo ba Mosebetsi Ela hloko
Mocheso oa tikoloho 23℃±1 -10℃~40 ----
Mongobo oa Tikoloho 40%60% 80% ----
Voltage e sebetsang 9V±0.1V 9V±1.5V ----
Thuso ea ho hanyetsa Lefatše 100Ω 30kΩ rC,rP
Matla a tšitiso ---- 20V ----
Tšitiso ea hona joale ---- 2A ----
Electrode sebaka sa teko ea R a5d a5d ----
Electrode sebaka saρteko a20h a20h ----

2. Litlhaloso Kakaretso

Mesebetsi 2-pole/ 3-pole/ 4-poleTekanyo ea ho hanyetsa lefats'e,resistivity mobu,matla a lefatše, motlakase oa ACtekanyo.
Phepelo ea motlakase DC 9V(Zn-Mn betri e omileng ea R14S 1.5V 6 likotoana,Tsoelang pelenako ea standby300hrs)
Range Ho hanyetsa Lefatše: 0.00Ω30.00kΩ
Ho hanyetsa Mobu: 0.00Ωm9000kΩm
Matla a lefats'e: 0V-600V
Mofuta oa tekanyo 4- palo,3-pole, tekanyo ea 2-pole earth resistance.
Mekhoa ea ho Lekanya Ho hanyetsa lefats'e: Mokhoa oa hona joale oa ho fetola lipalo.Lekola Current Max.20mA
Ho hanyetsa mobu: mokhoa oa lipalo tse 4 (Mokhoa oa Wenner).
Matla a lefats'e : Karolelano ea ho lokisa[P(S)-ES kou]
Maqhubu a Teko 128Hz/111Hz/105Hz/94Hz(AFC)
Teko e Khutšoanyane ea Potoloho ea Hona Joale AC 20mA max
Open Circuit Test Voltage AC 40V boholo
Teko ea Voltage Waveform Leqhubu la Sine
Sebaka sa Bohole ba Electrodes E ka behoa1m-100m
Level Switch Ho hanyetsa Lefatše: 0.00Ω-30.00kΩ Auto switchng.
Ho hanyetsa Mobu: 0.00Ωm-9000kΩm Auto switchng.
Backlight Lebone la morao-rao la skrini se putsoa
Mohlala oa Pontšo Pontšo ea 4 ea dijithale ea LCD, Lebone la morao-rao la skrini se putsoa
Leseli la Pontshi Leseli la LED nakong ea tlhahlobo, Pontšo ea ho bala ha LCD
LCD Dimension 128mm * 75mm
Pontšo ea LCD 124mm * 67mm
Boemo 215mm*190mm*95mm
Mekhoa e Tloaelehileng ea Tlhahlobo e Tsamaisang Kakaretso ea 4 e etella pele: 1 * E khubelu20m, 1* Ntsho20m, 1* Bosehla10m, 1*Botala10m
Litlhahlobo tse Bonolo 2 e etella pele: 1 * E khubelu 1.6m,1*E ntšo 1.6m
Li-Electrode tsa Ground tse thusang Likotoana tse 4:φ10 limilimithara×150 limilimithara
Nako ea Tekanyo Matla a tlase: hoo e ka bang makhetlo a 3 / sec
Ho hanyetsa lefats'e, ho hanyetsa mobu: hoo e ka bang metsotsoana e 5 / nako
Linako tsa Tekanyo Ka makhetlo a fetang 5000 (teko e khuts'oane ea potoloho, teko ea 1, emisa metsotsoana e 30 ebe u leka)
Potoloho ea Voltage Ho leka ka tlase ho AC 600V
Boema-kepe ba puisano Sehokelo sa USB, data e tšoaretsoeng ka hlooho e ka romelloa ho PC ho e boloka le ho e hatisa.
Moetapele wa Puisano USB,1.5m * 1 sekotoana
Polokelo ea Boitsebiso 300 sehlopha,MEMpolokelo e bontša,KHAHLILE”aekhone ho bontša hore polokelo e tletse
Data Hold Ts'ebetso ea ho ts'oara data: "HOLD" pontšo ea letšoao
Lintlha Tse Baloang Mosebetsi oa ho bala data: "BALA" pontšo ea letšoao
Pontšo e Phallang E feta mosebetsi oa ho lekanya oa phallo: "OL" pontšo ea matšoao
Teko ea Tšitiso Lemoha lets'oao la tšitiso ka bohona, wkgohomatla a ho kena-kenanafeta5V,ho na le "LESOA” temoso ya alamo
Teko ea motheo e thusang 0.00KΩ-30kΩ(100R+rC<50kΩ, 100R+rP<50kΩ)
Mosebetsi oa Alamo Ha boleng ba ho metha bo feta boleng ba ho seta alamo, ho na lemolumoalamo
Matla a Battery Ha matla a betri a fokotseha ho fihla ho 7.5V, aekhone e tlase ea matla a betri" ”e tla bonts'a, e hopotsa hotefiso
Tšebeliso ea Matla Ema haufi:ka20mA (backlight e koetsoe)
Backlight: ka 45mA(Lebone la morao le tima 25mA)
Tekanyo:hoo e ka bang 100mA (backlight e koetsoe)
Boima ba 'mele Boima bo felletseng ka mokotla: 4.5kg
Mohlahlobi: 950g (ho kenyeletsoa le betri)
Mehala ea ho LekaLilemo: 1560g
Molamu o thusang oa mobu:935g4PCS)
Mocheso oa Mosebetsi le Mongobo -10 ℃-40 ℃, ka tlase ho 80%rh
Mocheso oa polokelo le mongobo -20 ℃-60 ℃, ka tlase ho 70%rh
Tšireletso e Felletseng Ho lekanya lefats'e ho hanyetsa: lipakeng tsa sebaka ka seng saC(H)-E,P(S)-ES, AC 280V/3 metsotsoana
Khanyetso ea Insulation Fetile20MΩ(pakeng tsa potoloho le sebaka se kampetsoeng ke 500V)
Ho mamella Voltage AC 3700V/rms (Pakeng tsa potoloho le sebaka se koalehileng)
Likarolo tsa Electromagnetic IEC61326(EMC)
Mofuta oa Tšireletso IEC61010-1(CATIII 300V, CAT IV 150V, tekanyo ea tšilafalo2);
IEC61010-031; IEC61557-1(Ho hanyetsa Lefatše);
IEC61557-5(Ho hanyetsa Mobu); JJG 366-2004

3. Phoso ea motheo le ts'ebetso tlas'a boemo bo tloaelehileng

Lintho Lekhalo la litekanyo Ho nepahala Qeto
Kganetso ya lefatshe(R) 0.00Ω30.00Ω ± 2%rdg±3dgt 0.01Ω
30.0Ω300.0Ω ± 2%rdg±3dgt 0.1Ω
300Ω3000Ω ± 2%rdg±3dgt
3.00kΩ30.00kΩ ± 4%rdg±3dgt 10Ω
Ho hanyetsa mobu (ρ)
 
0.00Ωm99.99Ωm Ho latela ho nepahala ha R(ρ=2πaR
ke:1 m-100m;
π=3.14)
0.01Ωm
100.0Ωm999.9Ωm 0.1Ωm
1000Ωm9999Ωm 1Ωm
10.00kΩm99.99kΩm 10Ωm
100.0kΩm999.9kΩm 100Ωm
1000kΩm9000kΩm 1kΩm
Matla a lefats'e AC 0.0600V ±2%rdg±3dgt 0.1V

Maikutlo:1. phoso e eketsehileng: ≤± 3%rdg ± 5dgt tlas'a rC max kapa rP max.(rC boholo: 4kΩ+100R<50kΩ, rP boholo: 4kΩ+100R<50kΩ)
2. phoso e eketsehileng: ≤± 5%rdg ± 5dgt tlas'a motlakase oa 5V oa ho kena-kenana


  • E fetileng:
  • E 'ngoe:

  • Re romelle molaetsa oa hau:

    Ngola molaetsa wa hao mona mme o re romele wona

    Re romelle molaetsa oa hau:

    Ngola molaetsa wa hao mona mme o re romele wona