GDB-P Auto Transformer e Fetola Ratio Tester
Ho latela IEC le litekanyetso tsa naha tse amehang, tlhahlobo ea karo-karolelano ea li-transformer ke projeke e hlokahalang ts'ebetsong ea tlhahiso ea li-transformer tsa motlakase, phepelo ea basebelisi le tlhahlobo ea tlhokomelo.Mokhoa ona o ka lekola ka nepo boleng ba lihlahisoa tsa transfoma fekthering le ts'ebetso ea ts'ebeliso, ho thibela phetoho ea transformer hore e fetole potoloho e khuts'oane, potoloho e bulehileng, phoso ea khokahano, phoso ea kahare kapa phoso ea ho ikopanya le mochine oa ho fetola.
GDB-P Transformer turns ratio tester e na le litšobotsi tsa ts'ebetso e bonolo, ts'ebetso e felletseng, data e tsitsitseng le e tšepahalang.Ho fihlela joale, GDB-P ke ea pele ea Chaena e ka khonang ho etsa litekanyo tse foufetseng (ho etsa hore tekanyo e nepahetseng le tekanyo ea mohato oa ho lekanya ntle le ho tseba mokhoa oa ho hokahanya le boemo ba sehlopha sa transformer e lekiloeng);E ka khahlanyetsa litlhoko tsa liteko tse fapaneng tse kholo, tse mahareng le tse nyane tsa li-transformer (ho kenyeletsoa li-transformer tsa mofuta oa Z, li-transformer tse nchafatsang, li-transformer tsa sebopi sa motlakase, li-transformer tse se nang ntlha tsa ntlha tse fetohang, li-transformer tsa traction, Scott le li-transformer tsa Scott).
GDB-P e amohela LCD e kholo ea mebala e felletseng bakeng sa ponts'o, sebopeho se felletseng sa graphical sa Senyesemane se nang le tlhaiso-leseling, sebopeho sa ponts'o ea li-parameter tse ngata, ponts'o ea graph ea vector le kahlolo ea wiring e fana ka motheo o tšepahalang oa ho lekola ho nepahala ha potoloho.Mokhoa o felletseng oa ts'ebetso ea li-silicone e sebetsanang le keyboard, e sebetsang hantle, e bonolo ho ithuta.E hahiloe ka har'a polokelo ea data e kholo, E ka boloka data ea tlhahlobo ea sebaka sa marang-rang ho fihla ho lihlopha tse 1000.E ka fana ka software ea taolo ea microcomputer ea morao-rao, ea fetisetsa liphetho komporong ka U disk, ea hlahisa litlaleho, ea hatisa, le ho hlokomela taolo ea komporo.
Sesebelisoa se nka khetla ea polasetiki ea boenjiniere, e ntle ebile e sebetsa.
●Teko ea 'nete ea mekhahlelo e meraro: ho kenya matla a mohato o le mong, motsoako oa ka hare oa dijithale oa mekhahlelo e meraro, o hlahisa mohloli oa matla a liteko a mekhahlelo e meraro (ho khopama ho ka tlase ho 0.1%, symmetry e betere ho feta 0.05%) matla a phahameng a ho tšepahala, sephetho sa teko se na le ho lekana ho molemo, 'me ho ke ke ha e-ba le tlhaloso e fosahetseng ea sehlopha.
●E matla: e khona ho etsa litekanyo tsa mohato o le mong, empa hape le tlhahlobo ea othomathike ea mekhahlelo e meraro e ka phethahala.Ho lekanya polarity, angle ea mohato ka karolo e le 'ngoe le e meraro, tekanyo e feletseng ea AB, BC, CA karo-karolelano ea mekhahlelo e meraro le boleng ba angle angle, phoso, le boemo ba pompong, litekanyetso tsa ho tlanya hang-hang, li ka tsebahatsa nomoro ea sehlopha.
●Ts'ebetso ea ho lekanya li-angle tsa mohato: ho lekanya ka nepo sekhahla sa mohato lipakeng tsa lehlakore le phahameng le le tlase la voltage, karo-karolelano le angle ea non-integer transformer e ka lekanyetsoa.
●Ts'ebetso ea ponts'o ea li-angle tse tšeletseng: liphetho tsa liteko li bonts'oa ka palo le setšoantšo sa vector angle tse ts'eletseng, 'me boemo ba sehlopha sa khokahanyo ea transformer bo bonoa ka mokhoa o hlakileng.
●Ts'ebetso ea tlhahlobo e foufetseng: ha ho hlokahale hore u khethe mokhoa oa ho hokahanya le sehlopha sa khokahanyo, ha ho hlokahale hore u tsamaee potoloho e khutšoanyane ea ka ntle ha u lekanya Y / △, △ / Y transformer, mokhoa oa ho hokahanya o ka fetoloa ka bohona ho latela litaba tse khethiloeng tsa teko.Tekanyo ea palo le palo ea sehlopha e ka etsoa ho transformer ntle le nameplate.
●Teko ea ho tlanya: tekanyo e potlakileng ea karo-karolelano le phoso ea karohano sebakeng sa phetoho e 'ngoe le e 'ngoe ea theipi, tekanyo e lekantsoeng e hloka feela ho kenya hanngoe, ha ho hlokahale hore u phete ho kenya ho bala phoso ea karolelano ea boemo bo bong le bo bong ba ho theipi.
●Phetoho ea karo-karolelano le ts'ebetso ea ho lekanya karo-karolelano ea motlakase, tekanyo e sebetsang e ka bonts'a boleng ba 'nete ba karo-karolelano ea motlakase ea transformer tlas'a maemo a sebetsang.
●Khanyetso e ntle ea ho thothomela: ts'ebeliso ea likhokahanyo tsa sesole e ntlafalitse ts'ebetso ea anti vibrate.
●E amohela skrine ea mebala e phahameng ea 5.6 inch, ponts'o ea data le phello ea setšoantšo sa vector lia utloahala ebile lia tiea.
●Mohloli o hlophisitsoeng oa dijithale oa sine oa dijithale, tšitiso e ka tlase ho 0.1%, e sa angoeng ke boleng ba matla a ho sebetsa.
●E loketseng ho jara: molumo o monyenyane, boima bo bobebe.
●Betri e ka nchafatsoang ka hare, tlhahlobo e ka phethoa ntle le phepelo ea motlakase setšeng.
●Karolelano ea tekanyo ea tekanyo: 0.8 ~ 10000
●Lebelo la ho lekanya: tlatsa tlhahlobo ea mekhahlelo e meraro ka metsotso e 1
●Ho nepahala ha ho lekanya: ho nepahala ha voltage ea lehlakore la HV: 0.05%
ho nepahala ha matla a lehlakoreng la LV: 0.1%
ho nepahala ha angle ea mohato: 0.1 °
ho nepahala ha karo-karolelano: 0.1% (0.8-3000)
0.2% (3000-10000)
●Boima: 3kg.
●Phepelo ea matla: 220V ± 10%, 50Hz ± 1Hz
●Mocheso: -20℃ ~40℃
●Mongobo o batlang o lekana: ≤85%, o sa fokotseheng