GD2000D Insulation Resistance Tester
GD2000D tlhahlobo ea khanyetso ea dijithale ea GD2000D e hlahisoang ke k'hamphani ea rona e sebelisa sistimi e kenelletseng ea ts'ebetso ea nako ea nnete ea chip.Pontšo ea "analog pointer" le "digital field code" li kopantsoe hantle.Letoto lena la limithara le na le mefuta e fapaneng ea maemo a phallo ea motlakase (250V, 500V, 1000V, 2500V, 5000V, 10000V), matla a maholo, matla a ho thibela tšitiso, pointer ea analog le ponts'o ea digital, AC le DC ts'ebeliso e habeli, ts'ebetso e bonolo, palo e ikemetseng ea matšoao a fapaneng a ho kenya letsoho (karolelano ea ho monya, index ea polarization), liphetho tse fapaneng tsa litekanyo tse nang le ts'ebetso e khahlanong le ho theola matla, joalo-joalo Ke sesebelisoa se loketseng sa teko bakeng sa ho lekanya ho hanyetsa ha insulation ea li-transformer tse kholo, li-transformer, lijenereithara, tse phahameng- li-motor tsa motlakase, li-capacitor tsa motlakase, lithapo tsa motlakase, le lintho tse thibelang lehalima.
DL/T 474-2006 "Tataiso bakeng sa tlhahlobo ea Insulation setšeng"
DL/T 845-2004 "Litlhaloso tse akaretsang tsa ho lekanya lisebelisoa tsa ho hanyetsa"
DL/T 846-2004 "Litlhaloso tse akaretsang tsa tekheniki bakeng sa lisebelisoa tse phahameng tsa tlhahlobo ea motlakase"
DL/T 596-2005 "Khoutu ea tlhahlobo ea thibelo ea lisebelisoa tsa motlakase"
GB50150-2006 "Teko e tloaelehileng bakeng sa tlhahlobo ea letsoho ea lisebelisoa tsa motlakase tsa lisebelisoa tsa motlakase"
GB/T16927.1 ~ 2-1997 "Mekhoa e phahameng ea teko ea motlakase"
GB4793-1984 "Khokahano ea insulation bakeng sa phetisetso ea motlakase o phahameng le lisebelisoa tsa kabo"
1. Phallo ea motlakase (250V / 500V / 1000V / 2500V / 5000V) . Lebelo la ho hanyetsa 0-200GΩ.
2. Mefuta e 'meli e bonts'a khanyetso ea insulation.
3. Auto-calculating absorption ratio le polarization index.
4. Ts'ebetso ea botsoalle, ho boloka liphetho tsa tekanyo ea makhetlo a 19.
5. Auto-dicharge residual high voltage ka mor'a hore tlhahlobo e felile.
6. Phepelo ea matla a AC/DC, e nang le betri e ka nchafatsoang kapa adaptara ea AC.
7. Bokhoni bo matla ba ho thibela tšitiso, ho bala ho tsitsitseng le ho tšepahala.
8. Moqapi o nkehang, o loketseng mosebetsi o hlaha.
9. Nako e khutšoanyane ea nako e khutšoanyane ≥3mA, lisebelisoa tse loketseng bakeng sa ho hlahloba ho hanyetsa ha mocheso oa transformer e kholo, inductor, jenereithara, li-motors tsa HV, capacitor ea motlakase, lithapo le ho ts'oaroa ha surge.
Ntho No. | GD2000D | ||||||
Matla a tsoang | 250V DC | 500V DC | 1000V DC | 2500V DC | 5000V DC | ||
Ho nepahala | Mocheso | 23℃±5℃ | |||||
Insulation resistance | 250-5G ±5% | 50-10G ±5% | 1M-20G ±5% | 2.5M-50G ±5% | 5M-100G ±5% | ||
Mefuta e meng: ± 10% | |||||||
Matla a tsoang | 2M-10G ±5% | 4M-20G ±5% | 8M-40G 0--+10% | 20-100GΩ 0 --+10% | 40-200G 0-- +10% | ||
Short-circuit current | ≥3mA | ||||||
Phepelo ea motlakase | 8*Mofuta oa AA o phahameng betri e ka nchafatsoang le adaptara ea kantle | ||||||
Mocheso o sebetsang.& Mongobo | -10℃--40℃, mongobo o phahameng ka ho fetisisa 85% | ||||||
Mocheso oa polokelo.& Mongobo | -20℃--60℃, mongobo o phahameng ka ho fetisisa 90% | ||||||
Insulation | Max.2000MΩ ha voltage pakeng tsa potoloho le khetla ke 1000VDC. | ||||||
E mamella voltage | E mamella 1min ha voltage pakeng tsa potoloho le khetla e3kV50Hz SineMatla a AC | ||||||
Boemo | 230mm*190mm*90mm (L*W*H) | ||||||
Boima ba 'mele | 3kg |
Mohloli oa ho hanyetsa mocheso | 1 sete |
Teko terata | 1 sengoathoana |
Adapter ea matla | 1 sengoathoana |
Thapo ea matla | 1 sengoathoana |
Tataiso ea mosebelisi | 1 kopi |
Setifikeiti | 1 kopi |