GDTL AC Resonant Test System bakeng sa lijenereithara
GDTL letoto la AC Resonant Test System bakeng sa Jenereithara e ka sebelisoa ka ho lokisa inductance ea reactor, kapa ho lokisa tsela ea mosebetsi ea maqhubu a resonant ea sistimi ho fihlela molumo.Mekhoa e 'meli e ka sebelisoa ho fihlela resonance.Ts'ebetsong ea ho matlafatsa motlakase, haeba ntlha ea resonant e kheloha, e ka fumanoa hantle ka tsela ea maqhubu a tokiso e nepahetseng, a netefatsang boleng bo phahameng ba Q le ho fokotsa matla a matla le boima ba boima ba lisebelisoa tsa tlhahlobo.
●Boholo bo nyane, boima bo bobebe ha bo bapisoa le boemo ba motlakase o tšoanang, jenereithara ea matla a tšoanang a AC e mamella lisebelisoa tsa tlhahlobo ea motlakase. Thepa e le 'ngoe ha e fete 60kg, ho bonolo ho tsamaea.
●Molao-motheo o tsoetseng pele oa sesebelisoa se felletseng le theknoloji e ncha ea frequency & inductance modulation, e netefatsa ka tieo hore maqhubu a jenereithara a mamella litlhoko tsa tlhahlobo ea voltage.Sebaka se pharaletseng sa ts'ebeliso.
●E na le mohloli o fapaneng oa taolo ea 20Hz-300Hz.Tšireletso e ntle le tlhahiso ea waveform, botsitso bo phahameng.Ka mekhoa e mengata ea ho sebetsa, ho bonolo ho e sebetsa.
●Phepelo ea matla ea 220V kapa 380V, e loketseng ho fumana matla sebakeng sa marang-rang.
●Max.Q ntlha e ka fumanoa hantle ka mokhoa oa pele oa inductance modulation le hamorao frequency modulation, ho qoba resonance deviation ka lebaka la ho eketseha ha motlakase;
●Phetoho e feto-fetohang le katoloso e matla.Kopana le litlhoko tsohle tsa tlhahlobo ea capacitive test mochining oa motlakase.
●Mokhoa oa teko ea maqhubu a matla kapa Mokhoa oa teko oa maqhubu a Variable.
●Tšebeliso e ngata, e nang le litšenyehelo tse ngata.
●E lekanyelitsoeng tlhahiso ea matla: 0 ~ 50kV (RMS) kapa ka tlase.
●Khafetsa ea tlhahiso: 45 - 300Hz.
●Waveform: sine wave e hloekileng, THD ≤ 1%.
●Max.matla: 2000kVA kapa ka tlase.
●Potoloho ea mosebetsi: 15mins e tsoelang pele ea ho sebetsa ka nako e le 'ngoe ka tlhahiso e felletseng ea matla.
●Boemo ba boleng: 10 - 40.
●Maikutlo a ho fetola hangata: 0.1HZ, ho se tsitse ha <0.05%.
●Phepelo ea matla: 220V kapa 380V ± 15%, 50HZ ± 5%.
GDTF- 100/50 | |
Matla a kenang (V) | 380 |
Matla a tsoang (kV) | 0-50 |
Bokhoni (kVA) | 100 |
Sebaka sa kopo | Jenereithara--bokhoni ba ho ea fatše 0.07-0.13 μF |
10 kV (300 mm² ) cable ≤ 1 km | |
Litlhophiso tsa mantlha | 50kV/1A Reactor e tsitsitseng 1 sete |
50kV/1A sete e 1 e fetolehang | |
Capacitive divider 50kV | |
GDTF-150/50 | |
Matla a kenang (V) | 380 |
Matla a tsoang (kV) | 0-50 |
Bokhoni (kVA) | 150 |
Sebaka sa kopo | Jenereithara--bokhoni ho ea fatše 0.13-0.2 μF |
10 kV (300 mm² ) cable ≤ 1.5 km | |
Litlhophiso tsa mantlha | 50kV/1.5A Reactor e tsitsitseng 1 sete |
50kV/1.5A Actor e fetolehang e le 1 sete | |
Capacitive divider 50 kV | |
GDTF- 225/50 | |
Matla a kenang (V) | 380 |
Matla a tsoang (kV) | 0-50 |
Bokhoni (kVA) | 225 |
Sebaka sa kopo | Jenereithara--bokhoni ho ea fatše 0.2-0.27 μF |
10 kV (300 mm² ) cable ≤ 2.5 km | |
Litlhophiso tsa mantlha | 50kV/1.5A Sets'oants'o se tsitsitseng sa 2 sete |
50kV/1.5A Actor e fetolehang e le 1 sete | |
Capacitive divider 50 kV | |
GDTF- 360/60 | |
Matla a kenang (V) | 380 |
Matla a tsoang (kV) | 0-60 |
Bokhoni (kVA) | 360 |
Sebaka sa kopo | Jenereithara--bokhoni ba ho ea fatše 0.27-0.33 μF |
Litlhophiso tsa mantlha | 60kV/2A Reactor e tsitsitseng ea sete e le 'ngoe |
60kV/2A Actor e fetolehang e le 1 sete | |
Capacitive divider 60kV |