GDUP Series AC Power Supply
GDUP-6000 (GDUP-3000) ke sesebelisoa sa motlakase se nkehang habonolo sa sine wave setšeng sa AC.E boetse e tsejoa e le phepelo ea matla ea liteko tsa AC le DC sebakeng sa marang-rang, phepelo ea motlakase ea tšohanyetso ea AC le DC, phepelo ea motlakase ea liteko tsa masimong, phepelo ea motlakase ea tlhahlobo ea mohala.E na le matla a sireletsehileng a betri ea lithium-ion le theknoloji e sebetsang ea SPWM ea ho fetola inverter, e nang le boima bo bobebe, boholo bo nyane, bophelo bo bolelele le bokhoni bo phahameng.
E sebelisoa haholo lisebelisoa tsa ka ntle tse kang tokiso ea ts'ohanyetso ea lisebelisoa tsa motlakase, teko ea matla a motlakase, ofisi ea selefouno, pholoso ea bongaka, pholoso ea tšohanyetso ea mollo, tšireletso ea tikoloho, tšehetso ea puisano ea tšohanyetso, le polokelo ea polokelo ea matla.E boetse e fana ka mohloli o sireletsehileng le o ka tšeptjoang oa matla bakeng sa lisebelisoa tsa laboratori kapa tšimong.
1. 220V / 50Hz pure sine wave AC tlhahiso
2. E ka iketsetsa tlhahiso ea 110V, 60Hz (ho romela Japane le European Union)
3. Phallo ea 12V / 10A DC, 5V / 2A-USB e hlahisoang ke li-port tse peli;
4. 24V / 20A DC tlhahiso;
5. Lebone la tšohanyetso la LED;
6. Pontšo e bohlale, e bonts'a matla a dijithale a betri, matla a ho kenya le ho tsoa le nako e setseng ea ho sebetsa;
7. Chaja ea koloi, ho tjhaja letsatsi (ho ikhethela)
●E hahiloeng ka har'a betri ea lithium ea polymer e nang le matla a maholo, bokhoni bo boholo, ho tjhaja le ho tjhajoa ho bolokehileng haholo, ha ho cheso, ha ho ho phatloha.
●Ho feta 1000 li-cycle tsa ho tjhaja le ho ntša.
●Sebetsa hantle ka hare ho -20 ℃ ~ +50 ℃.
●Tshebetso e phahameng, ha ho na tšilafalo, tikoloho-ba botsoalle.
●Ho itšehla thajana: ka mocheso oa kamore bakeng sa khoeli e le 'ngoe, ho itšehla thajana ho ka tlase ho 5%.
●Ka tlhahiso ea DC 5, 12, 24V, AC 110V / 220V tlhahiso.
●E na le ts'ebetso ea cascading output, e ka khonang ho fetoha ka mokhoa o itekanetseng pakeng tsa mehloli ea motlakase e kholo le e thusang, le ho eketsa nako ea phepelo ea motlakase ka ho phalla ka mekhahlelo e mengata.
●Sesepa sa LCD sa boholo bo boholo, motlakase o khahlang mahlo, li-parameter tsa hajoale le tse ling.
●AC pure sine wave e hlahisoang ka boima bo matla ba mojaro.
●E na le ts'ebetso ea ts'ireletso ea othomathike joalo ka ho tjhaja ho feta tekano, ho tsoa ho feta tekano, ho tlala, ho chesa haholo le potoloho e khuts'oane.
●E nyane, e bobebe ebile e matla: betri ea matla a tšoanang e tlase ho 50% ho feta boima ba asiti ea lead.Tlas'a matla a tšoanang a ho jara, sebaka sa fatše se ka bang 30% feela ea betri ea lead-acid.
●Lokisa mokotla o khethehileng, o bonolo ho o jara.
●Sekhahla sa ho boloka betri bakeng sa likhoeli tse 12 ke ≥80.
●Boemo ba ts'ireletso ea betri: IP56.
Mohlala | GDUP-6000 (GDUP-3000) |
Matla a tsoelang pele a hlahisoang | 3000W |
Matla a phahameng | 6000W |
Matla a tsoang | AC pure sine wave 220V/50HZ kapa AC 110V/60HZ DC 12V10A 48V50A ( 5V2A 24V20A 51.8V50A 5V2A) |
Mohlala oa betri | 3.7V2600mAh(14S42P) |
Bokhoni | 51.8V 109.2AH (51.8V 57.2AH) |
Bophelo ba tšebeletso | 70%@1000 potoloho |
Mofuta oa Leshala | Betri ea lithium-ion |
Nako ea ho tjhaja | Lihora tse 7-8 (lihora tse 5 ~ 6 (tjhaja ea ka hare 58.8V 10A) |
Ho tjhaja motlakase le hona jwale | DC 58.8V 15A matla a letsatsi 72V AC 80~260V 15A (tjhaja) |
Tshireletso | Over-voltage, over-themperature, over-load, AC short circuit, auto recovery |
Leseli la LED | 60W*2 (ho ikhethela) |
Boemo ba mosebetsi | -20 ℃ ~ 60 ℃ |
Mokhoa oa ho pholisa | Fene e qobella ho pholile |
Boholo | L560*W450*H200 (mm) (L515.5*W434.5*H270 (mm)) |
Lintho tsa khetla | UL94-V0 ABS (Anti-shock ABS) |
Boima ba 'mele | 38kg (33kg) |
No | Ntho ea teko | Maemo a teko | Sheba ntho |
1 | Teko ea bophahamo | 1. Khatello ≤11.6Kpa, T =20±5℃ 2. Ha ho sephutheloana, ha ho na motlakase | 1. Ponahalo 2. Ts'ebetso ea phepelo ea motlakase |
2 | Teko ea mocheso | Mocheso o pakeng tsa 40±2℃ le 75±2℃ Teko e phetoa ka makhetlo a 10 Kenya matla ka metsotso e 30. | 1. Ponahalo 2. Ts'ebetso ea phepelo ea motlakase |
3 | Teko ea vibration | Boholo: 1.52mm Sebaka sa maqhubu a ho skena: 5 ~ 10Hz, lebelo la ho hlahloba: hoo e ka bang 10m2/ S3, Lebelo la maqhubu a ho hlahloba: 0 ~ 200Hz, lebelo la ho hlahloba: hoo e ka bang 3m2/ S3, Sebaka sa maqhubu a ho hlahloba: 200 ~ 500Hz, lebelo la ho hlahloba: hoo e ka bang 1m2/ S3, Teko e 'ngoe le e' ngoe ea vibrate e nka metsotso e 20.Ho thothomela ho etsahala ho tsoa mahlakoreng 'ohle a axis ea X, Y le Z.Ponahalo e lula e tiile, sehlahisoa se ka feta liteko tsohle tsa ts'ebetso, 'me mongolo ho label o hlakile, hammoho le litaelo tsa ts'ebetso.Sehlahisoa ha se na ho thothomela ebile ha se lerata;Sekoti se tiisitsoe ka thata ntle le ho thella. | 1. Ponahalo 2. Ts'ebetso ea phepelo ea motlakase |